Login:
Sortierung : Dateiname ↑   heruntergeladen   Bewertung   Dateigröße ↑  

AMT Datasouth 4000

heruntergeladen wurde: 34Dateigröße: 1 mb    Hersteller: AMT Datasouth  
Kategorie: Drucker

h width multiplier ‘1’ to ‘9’ and ‘A’ to ’ O’. ‘0’ stands for default. v height multiplier ‘1’ to ‘9’ and ‘A’ to ’ O’, ‘0’ stands for default. eee bar code height This is ignored for box, line and graphics. It represents point size for font ‘9’ and symbol set for Courier font** . yyyy Y coordinate xxxx X coordinate depends on object types User's Guide 53 Object Command Structure Description L : line (if t is ‘X’) Lwwwhhh www : width, hhh : height. L : line (if t is ‘X’) lwwwwhhhh wwww :

AMT Datasouth 600

heruntergeladen wurde: 27Dateigröße: 2 mb    Hersteller: AMT Datasouth  
Kategorie: Drucker

0.1 0.1 3.9 1.9 0.01 Box would also work. % Box draw % botX(in.) botY(in.) topX(in.) topY(in.) lwidth(in.) Box 0.1 0.1 3.9 1.9 0.01 Box Fastmark 600 Series User's Guide Demo Label showing use of Print Utility Procedures After the file Pal_Procs_and_Formats.txt has been copied to the printer, a number of new procedures are now defined in the printer (until powered off). These procedures have been written specifically to demonstrate how to use the PALTM Print and Program operators to produce print

AMT Datasouth 7200

heruntergeladen wurde: 10Dateigröße: 2 mb    Hersteller: AMT Datasouth  
Kategorie: Drucker

D Contents... Table of Introduction.............................................................. i 1. Before Using the ATB Printer.........................1-1 1.1 Checking the Package ....................................................... 1-2 1.2 Names and Functions ........................................................ 1-3 2. Operation..........................................................2-1 2.1 Connecting the ATB Printer..............................................2-2 2.2 Turning the

AMT Datasouth 5350s

heruntergeladen wurde: 8Dateigröße: 190 kb    Hersteller: AMT Datasouth  
Kategorie: Drucker

It provides added versatility by combining a super-impact printhead with a powerful bottom-feed forms tractor to conquer even the most impossible jobs! The Paper Handling Expert • Straight-thru paper path • Single/dual tractor models plus cut sheet • Cut form sets up to 33" long • Snap-in printer cartridge and color printing The Form Pounder • 12-part forms with carbons capability • Tough 24-pin printhead, 480 cps print speed • Demand document Ready for Any Application • 5 standard em

AMT Datasouth DSm415

heruntergeladen wurde: 7Dateigröße: 989 kb    Hersteller: AMT Datasouth  
Kategorie: Drucker

Input Capacity: a) Standard 250 sheets tray x 1 100 sheets multi bypass tray* *Bypass tray and duplex unit do not work together. b) Options Paper Bank: 500 sheets x 1 Max total capacity: 850 sheets 5. Output Capacity: 250 sheets (internal tray) 6. Paper size / weight: a) Size: Standard Tray: A5 (LEF), A4 (SEF), 5 1/2” x 8 1/2” (LEF), 8 1/2” x 11”(SEF) Bypass Tray: A6 (SEF) – A4 (SEF), 5 1/2”x 8 1/2” - 8 1/2”x 14”(SEF) Irregular size: 90 - 216 x 139 - 600 mm 3.54” - 8.5” x 5.48” – 23.62” Duplex:

AMT Datasouth ACCEL-6300

heruntergeladen wurde: 5Dateigröße: 3 mb    Hersteller: AMT Datasouth  
Kategorie: Drucker

387002, Rev. E ® ™ AMT ACCEL-6300 P R I N T E R S E R I E S User's Guide Unpacking Set Up Loading Paper Control Panel Cleaning & Maintenance Solving Problems Bottom-Feed Tractors Bar Codes Interfaces Code Sets Specifications Document No. 387002 .. Revision E AMT Datasouth Corp. 4765 Calle Quetzal Camarillo, CA 93012 TEL: (805) 388-5799 FAX: (805) 484-5282 WEB: amtdatasouth.com User's Guideii Preface User's Guide Preface Thank you for selecting an AMT Datasouth® ACCEL™-6300 series printer. Using

AMT Datasouth documax 3300

heruntergeladen wurde: 5Dateigröße: 4 mb    Hersteller: AMT Datasouth  
Kategorie: Drucker

NOTE To eject a cut sheet form for any reason, press the Form Feed Key. Figure 3-7: Tear Off Bar Scale 3-10 Forms Handling User’s Guide NOTE If forms length is between 4.5” and 6.0”, verify that the Vertical Gap Position Feature is set to 0.0” (located under M8 Form Thickness in the setup mode). See Section 4.6 for further instructions on how to change this setting. Failure to set Vertical Gap for these forms may cause trailing edge of form to catch under guide during loading. Figure 3-8: Loadin

AMT Datasouth 6000

heruntergeladen wurde: 5Dateigröße: 2 mb    Hersteller: AMT Datasouth  
Kategorie: Drucker

110621 A IMPORTANT SAFETY INSTRUCTIONS AND OTHER NOTICES • This label printer complies with the requirements in Part 15 of FCC rules for a Class A computing device. Operation of this equipment in a residential area may cause unacceptable interface to radio and TV reception, requiring the operator to take whatever steps are necessary to correct the interference. • Place the printer on a flat, firm and solid surface. • Do not place the printer near a heat source or near water. • Refer to the speci

AMT Datasouth 4600

heruntergeladen wurde: 4Dateigröße: 3 mb    Hersteller: AMT Datasouth  
Kategorie: Drucker

................................ ................................ .... 2 Unpackin g ................................ ................................ ................................ ....... 2 Package Contents ................................ ................................ ........................... 3 Placing the Printer ................................ ................................ .......................... 4 Connecting the Powe r Cord ................................ ...................

AMT Datasouth Codewriter 4500 Series

heruntergeladen wurde: 4Dateigröße: 1 mb    Hersteller: AMT Datasouth  
Kategorie: Drucker

108738 Rev. C NOTICE There are no user-servicable parts inside the side access panel on theCodewriter 4500 Series products. Do not attempt to open the sideaccess panel without first turning off the power to the unit, disconnecting the power cord from the unit, and disconnecting allcommunication cables. All service procedures should be performed by a qualified servicetechnician. NOTICE This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: 1. Thi





Kategorien