a.) Replace ignitor. failed to detect or b.) Ignition cable defective. b.) Replace ignitor cable. sustain flame c.) Ignitor cable disconnected. c.) Connect ignitor cable. d.) Manual gas valve in “OFF” d.) Turn manual gas valve to “ON”. position. No gas to valve. e.) Defective wire to gas valve. e.) Replace defective wire. f.) Wire to gas valve disconnected. f.) Connect gas valve wire. g.) Obstruction to vent outlet. g.) Remove obstruction. h.) Obstruction to air inlet. h.) Remove obstruction. 3
8. Make sure no electrical wires or water pipes are in stud space selected. 9. RESIDENTIAL GARAGE INSTALLATION. Gas utilization equipment in residential garages shall be installed so that all burners and burner ignition devices are located not less than 18 inches {46 cm} above the floor. Unit should be located or protected so it is not subject to damage by a moving vehicle. Use care in selecting a good location within the garage. DO NOT locate the heater where heated air will be directed onto a
• Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. - INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER. WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury
Immediately call a qualified service • Do not touch any electric switch; do not technician to inspect the appliance and to use any phone in your building. replace any part of the control system and any • Immediately call your gas supplier from a gas control which has been under water. neighbor’s phone. Follow the gas supplier’s instructions. OPERATING INSTRUCTIONS 1. STOP! Read safety information on this label. 2. Set the thermostat to the lowest setting. 3. Turn off all electric power to the ap
CURING Logs During the 2-3 hour appliance break in period, you may detect an odor from appliance as the various paints and compounds used in the manufacturing of this log set cure. This is a normal and temporary situation that is not cause for alarm. However, you may want to provide extra ventilation to the room during this time. To ensure proper curing of logs: • Ignite a 2" flame and maintain for 1 hour • Burn logs in consecutive 1 hour periods raising flame an additional 2" to full height for
The charts in Figure 2, page 6 indicate technical information regarding the installation of your gas log set. Please make sure that all of the specifications shown are applicable before installation is attempted. The fireplace must include a flue and venting system with the minimum openings shown in Figure 2, page 6. Log Set Assembly Grate Ceramic Burner Chassis Figure 1 - Product Identification (Ramp Pan Burner) Installation Continued Model Burner DESCRIPTION Btu Input Minimum Vent Opening VTD-
Note: If pilot goes out, repeat steps 4 through 8. 9. Slightly push in and turn control knob counterclockwise to the ON position. 10. Wait one minute and switch selector switch to the ON position to light burners. 11. Set flame adjustment knob to any level between HI and LO. CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve. Operating Heater Continued Control Knob Selector Switch LOIHOFFPILOTONAUTOOFFON Flame Adjustment Knob Ignitor Button Figure 11 - Control Knob
See warranty for additional information. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from
The ceiling must be at least 41" from the fireplace opening. See Figure 3. Mantel Clearances Without Hood (Figure 4) You must have non-combustible materials above the fireplace opening. Non-combustible material must extend at least 12" above fireplace opening. With sheet metal, you must have noncombustible material behind it. Heat resistant materials such as slate and marble must be at least 1/2" thick. Sheet metal should not be installed onto combustible material. Figure 4 If your installation