Login:

Addonics Technologies ZBW-H63DEU

heruntergeladen wurde: 0Dateigröße: 3 mb    Hersteller: Addonics Technologies  
Kategorie: DVD-Player

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy. If not installed and used in accordance with the instructions, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If the equipment does cause harmful interference to radio or television reception, which can b

Addonics Technologies RAID TOWER IX RT93DAHXML

heruntergeladen wurde: 2Dateigröße: 132 kb    Hersteller: Addonics Technologies  
Kategorie: elektrische Heizungen

A single beep will be heard to indicate initialization is completed. The above steps act as a reset. d. Power off the system power. Technical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: 1 2 3 4 5SW1 BZS EZ M2 M1 M0 1 2 3 4 5SW1 BZS EZ M2 M1 M0 SW1 SW1 1 2 3 4 5SW1 BZS EZ M2 M1 M0 RAID 5 Mode 1 2 3 4 5 SW1 BZS EZ M2 M1 M0 BZS EZ M2 M1 M0 RAID 1& RAID 10 Mode Large Mode 1 2 3 4 5 SW1 1 2 3 4 5 SW1 1 2 3 4 5 e. On the DIP switch, change (M0 to M2) setting to the desired RAID mode u

Addonics Technologies RAID TOWER IX RT93DAHX

heruntergeladen wurde: 5Dateigröße: 132 kb    Hersteller: Addonics Technologies  
Kategorie: elektrische Heizungen

Installing drives into the RAID Tower V Step 1 Use a Philips screwdriver to secure the 3.5” SATA hard drive to the drive tray Step 2 Slide the tray into the Disk Array drive bay. Note: It is recommended to fill up the RAID Tower IX with SATA drives from top to bottom. This is to help in identifying which drives connects to which ports for easier troubleshooting. Note: The 5 port HPMXA system version PCB board is mounted inside the RAID tower and is connected to the multilane bridge that is mount

Addonics Technologies PCMCIA

heruntergeladen wurde: 9Dateigröße: 149 kb    Hersteller: Addonics Technologies  
Kategorie: Netzwerk

We welcome any valuable inputs you can provide us so we can continue to improve our services and products. Please email all your comments to atc@addonics.com or any technical related questions to techinfo@addonics.com. * Make sure you have enough space in your local hard drive. At least 4Gb or higher. The USB cable is an Addonics USB 2.0 interface cable. The process involved A. Set up the USB drives under DOS mode (step 1 - 9) B. Copy folders and files from your Windows installation CD to the ha

Addonics Technologies Network Adapter ADZIFCF

heruntergeladen wurde: 4Dateigröße: 2 mb    Hersteller: Addonics Technologies  
Kategorie: Netzwerk

The Compact Flash should be keyed to prevent the card from being incorrectly inserted. 2. Put the mechanism in the open position and slide the flat ribbon cable into the ZIF connector on the adapter. 3. Close the latch to secure the ribbon cable connection. 1.8” ZIF- CF adapter shown below attached to a 1.8” ZIF to 2.5” IDE converter 1.8” ZIF- CF adapter shown below connected to a 2.5” drive enclosure TECHNICAL SUPPORT Email: Internet: Technical Support (8:30 am to 6:00 pm PST) Phone: 4

Addonics Technologies NASU2

heruntergeladen wurde: 28Dateigröße: 5 mb    Hersteller: Addonics Technologies  
Kategorie: Netzwerk

This will allow the NAS adapter to obtain its IP address automatically. If you prefer setting it manually, select the static IP option, enter your own value and click “Apply” to confirm the new setting. Disk Utility In this page, you can manage hard disk settings of the USB storage device. Format: For first time installation, you need to format hard disk into FAT32 file system. Formatting the drive will erase all data on the hard drive. Warning: For hard drives with data on it, be fore you have

Addonics Technologies Mobile DVDR/RW

heruntergeladen wurde: 2Dateigröße: 134 kb    Hersteller: Addonics Technologies  
Kategorie: DVD-Player

CardBus mode – move the switch to the side with the DOT indicator Text Box: Text Box: Text Box: CardBus Text Box: PCMCIA Text Box: Front view Text Box: Factory default setting is CardBus mode CardBus/PCMCIA driver Installation For Windows 95, 98, 98SE and Me (Do not run the SETUP program from the driver disk, SETUP Is for DOS or WIN 3.1 using PCMCIA mode only) 1. Power on your system and wait for the Desktop screen. 2. Connect the CardBus/PCMCIA cable and external AC/DC adapter into the back of

Addonics Technologies Mobile DVD/CDRW

heruntergeladen wurde: 10Dateigröße: 107 kb    Hersteller: Addonics Technologies  
Kategorie: DVD-Player

This equipment generates, uses and can radiate radio frequency energy. If not installed and used in accordance with the instructions, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If the equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to try and correct the interference by one or

Addonics Technologies DVD R/RW

heruntergeladen wurde: 3Dateigröße: 118 kb    Hersteller: Addonics Technologies  
Kategorie: DVD-Player

# Since USB 2.0 Hi-Speed is an evolution of the existing USB 1.1 specification, it is fully forward and backward compatible with current USB systems. # If your computer’s USB controller is only USB1.1 you can only achieve a 4X maximum CD writing speed. # If you do not have a USB2.0 port, you may install an optional USB2.0 adapter or controller (see optional accessories section on page 13) to your computer to achieve the maximum DVD CD writing speed. USB interface cable installation Attach the US

Addonics Technologies AE25RDESU

heruntergeladen wurde: 0Dateigröße: 5 mb    Hersteller: Addonics Technologies  
Kategorie: Computer-Zubehör

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy. If not installed and used in accordance with the instructions, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If the equipment does cause harmful interference to radio or television reception, which can b





Kategorien