Essick Air 447 301

heruntergeladen wurde: 13Dateigröße: 321 kb    Hersteller: Essick Air  
Kategorie: Luftbefeuchter

REMOVING SCALE 6) Carefully lift wick from cabinet, allowing any water to drain from it into water channel. Place in sink or tray to finish draining. 7) Remove any remaining water in channel with a sponge. Fill water channel with one 8 oz. cup of undiluted white vinegar. Let solution stay 20 minutes. Remove with a sponge. Clean all interior surfaces with soft brush. Dampen soft cloth with undiluted white vinegar and wipe out water channel to remove scale. 8) Rinse water channel thoroughly with f

Essick Air 5000 DD

heruntergeladen wurde: 8Dateigröße: 656 kb    Hersteller: Essick Air  
Kategorie: Ventilatoren

In the event additional information is desired, your dealer will be more than glad to assist you in every possible way. 6 110503-1 3 Troubleshooting Problem Possible Cause Remedy Failure to 1. No electrical power to 1. Check power start or no air unit delivery • Fuse blown • Replace fuse • Circuit breaker tripped • Reset breaker • Electric cord unplugged • Plug in cords or or damaged replace if damaged 2. Belt too loose or tight 2. Adjust belt tension 3. Motor overheated 3. De

Essick Air 7D6 100

heruntergeladen wurde: 1Dateigröße: 974 kb    Hersteller: Essick Air  
Kategorie: Luftbefeuchter

Add bacteriostat Placement according to the instructions on the bottle. 6) Plug cord into wall receptacle and turn humidifier on. **When excessive condensation exists, a lower speed setting is recommended. CAUTION: Disconnect power before filling, cleaning or servicing unit. Keep grille dry at all times. OPERATION & CONTROLS – 1) The humidifier should be placed at least FOUR inches away from any walls and away from heat registers. Do not place on soft carpet. Unrestricted airflow into the unit w

Essick Air 12 SD

heruntergeladen wurde: 14Dateigröße: 877 kb    Hersteller: Essick Air  
Kategorie: Ventilatoren

0 CFM RPM 75/85 SD 95 SD 10/12 SD 14/21 SD CS 11/16 MODEL NO. Performance Tables above Power rating include drive Performance motors with CFM INCHES STATIC PRESSURE CFM INCHES STATIC PRESSURE 6868 420 6724 424 Champion Commercial Aspen Cooler Specifications Down DischargeDown Discharge Down DischargeDown Discharge Side DischargeSide Discharge Side DischargeSide Discharge Champion Cooler certifies that the evaporative air coolers shown here are licensed to bear the AMCA Seal. The ratings shown ar

Essick Air 821 000

heruntergeladen wurde: 0Dateigröße: 443 kb    Hersteller: Essick Air  
Kategorie: Luftbefeuchter

5 ESSICK AIR PRODUCTS HUMIDIFIER WARRANTY POLICY EFFECTIVE APRIL 1, 2008 SALES RECEIPT REQUIRED AS PROOF OF PURCHASE FOR ALL WARRANTY CLAIMS. This product is warranted against defects in workmanship and materials for one year from the date of sale except for motors, which are warranted for two years. This warranty does not apply to filters or wicks which are customer replaceable parts. This warranty applies only to the original purchaser of the product when it is purchased from a reputable retai

Essick Air 726 000 2-speed

heruntergeladen wurde: 0Dateigröße: 1 mb    Hersteller: Essick Air  
Kategorie: Luftbefeuchter

Place the top housing on a flat surface. REMOVING SCALE 5) The base, with water in the water channel, may be carried to the sink. Lift the wick from the base allowing excess water to drain into the channel. 6) Rinse the wick under freshwater only. Do not use soap, detergent, or any other cleaners on the wick. Leave in the sink to drain. 7) Empty the water from the base and water bottle. Fill the water channel and water bottle with one 8 oz. cup of undiluted white vinegar. Let stand 20 minutes. 8

Essick Air AD2C7112

heruntergeladen wurde: 5Dateigröße: 1014 kb    Hersteller: Essick Air  
Kategorie: Ventilatoren

Slide float shield (7) over float body (5) until it snaps into place. Wet Module Mounting Bolts Fig. 1 Drain Pump Hose Overflow Pipe Nipple Rubber Washer Bottom Pan Nut Fig. 2 Fig. 4 Electrical Installation ÊWARNING: Disconnect all electrical service that will be used for this unit before you begin the installation and leave it disconnected until the installation is complete. The control box is factory wired and installed for either 120 V or 230V operation depending on the model you

Essick Air 5D6 700

heruntergeladen wurde: 0Dateigröße: 185 kb    Hersteller: Essick Air  
Kategorie: Luftbefeuchter

When the humidity level drops below the set humidity, the humidifier will turn on automatically. 13) Turn humidifier ON, the humidity is regulated by using the HI/LO speed switch. AIR CARE® FILTERS The 5D6 700 has an optional two-stage air filter (#1050) that can be inserted into the top of the chassis which filters the air as it humidifies. The first stage of the air filter is a high-efficiency, electrostatically-charged filter media which traps dust, pollen and airborne pollutants. The second

Essick Air 3D6 100

heruntergeladen wurde: 2Dateigröße: 1 mb    Hersteller: Essick Air  
Kategorie: Luftbefeuchter

As air moves through the wick, the water evaporates into the air, leaving behind any white dust, minerals, or dissolved and suspended solids. Because the water is evaporated, there is just clean and invisible moist air. As the evaporative wick traps accumulated minerals from the water, its ability to absorb and evaporate water decreases. We recommend changing the wick at the beginning of every season. In hard water areas, more frequent replacement may be necessary to maintain your humidifier’s e

Essick Air d46720

heruntergeladen wurde: 1Dateigröße: 237 kb    Hersteller: Essick Air  
Kategorie: Luftbefeuchter

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state or province to province. This warranty does not cover damage resulting from misuse or abuse of the humidifier, accidents or alterations to the product, commercial use or damage during shipment. Misuse includes malfunctions caused by negligence in cleaning or parts fouled with mineral deposits due to hard-water conditions. Alterations to the product include the substitution of non-Essi