Login:
Sortierung : Dateiname ↑   heruntergeladen   Bewertung   Dateigröße ↑  

Kobe Range Hoods CH0042SQB

heruntergeladen wurde: 0Dateigröße: 2 mb    Hersteller: Kobe Range Hoods  
Kategorie: Ventilatoren

OPTIONAL RECIRCULATING KIT ALSO AVAILABLE. . FOR MORE INFORMATION, PLEASE VISIT OUR WEBSITE WWW.KOBERANGEHOODS.COM OR CONTACT KOBE RANGE HOODS AT (626) 350-1355. 3 INSTALLATION PLEASE READ ENTIRE INSTRUCTION BEFORE PROCEEDING Calculation before Installation To calculate installation, please refer to Table 1. (All calculation in inches.) -FOR UNDER THE CABINET TABLE 1 A = Height of Floor to Ceiling B = Height of Floor to Counter Top (Standard: 36”) C = Height of Counter Top to Hood Bottom (Recomm

Kobe Range Hoods CH8136SQ

heruntergeladen wurde: 2Dateigröße: 978 kb    Hersteller: Kobe Range Hoods  
Kategorie: Ventilatoren

. Always use cookware and utensils appropriate for the type and amount of food prepared. . Use this unit only in the manner intended by the manufacturer. . Before servicing, switch power off at service panel and lock service panel (if possible) to prevent power from switching on accidentally. . Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan, safety screens, and oil containers. 2 What to Do In The Event Of a Range Top Grease Fire - SMOTHER FLAMES with a close

Kobe Range Hoods CH0130SQB

heruntergeladen wurde: 1Dateigröße: 679 kb    Hersteller: Kobe Range Hoods  
Kategorie: Ventilatoren

Refer to Figure 12. Figure 11 Hood Installation CAUTION: If moving the cooking range is necessary to install the hood, turn off the power in an electric range at the main electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS RANGE. 1. Using references in Table 2 and Measurements and Diagrams on pages 19-20, mark the leveling point of the hood. Position two mounting screws (not provided) on the wall, leaving 1/8” away from the wall. Refer to Figure 13 Figure 12 9 2. Align hood-mounting bracket to

Kobe Range Hoods CH0030SQB (30")

heruntergeladen wurde: 8Dateigröße: 2 mb    Hersteller: Kobe Range Hoods  
Kategorie: Ventilatoren

What to Do If You Smell Gas • Extinguish any open flame. • Do not try to turn on the lights or any type of appliance. • Open all doors and windows to disperse the gas. If you still smell gas, call the Gas Company and Fire Department right away. CAUTION 1) For general ventilation use only. Do not use to exhaust hazardous or explosive materials and vapors. 2) To reduce the risk of fire, use only metal ductwork. Sufficient air is needed for proper combustion and exhausting of gases through the flue

Kobe Range Hoods CH7736SQ

heruntergeladen wurde: 1Dateigröße: 1 mb    Hersteller: Kobe Range Hoods  
Kategorie: Ventilatoren

IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN. CAUTION: TO REDUCE THE RISK OF FIRE AND ELECTRIC SHOCK, DO NOT USE WITH ANY SOLID-STATE SPEED CONTROL DEVICE. 5 - INSTALLING THE RANGE HOOD - (Keep all packing materials for return or exchange) Temporarily wire the hood to test for proper operation before installing. Before installing, please peel protective film off the hood first, if any. NOTE: The recommended distance from range

Kobe Range Hoods SH-L35W

heruntergeladen wurde: 5Dateigröße: 531 kb    Hersteller: Kobe Range Hoods  
Kategorie: Ventilatoren

The LCD Hood may become detached and you may damage the camera or injure yourself. • Do not allow magnetized objects to touch or come close to the LCD Hood. • When the LCD Hood is attached, the base of the hook may not touch the LCD screen frame. This is not a malfunction. • To open the LCD screen, press the OPEN button of the camera first. Hold the LCD screen to open it even when the LCD Hood is attached. If you hold the LCD Hood to try to open the LCD screen, the LCD Hood will become detached

Kobe Range Hoods CH0036SQB

heruntergeladen wurde: 0Dateigröße: 2 mb    Hersteller: Kobe Range Hoods  
Kategorie: Ventilatoren

6 Ductwork Installation Ductwork Installation 8. Use 8” round steel pipe (follow building codes in your area) to connect the ducting transition on the hood to the ductwork above. Use duct tape to make all joints secure and air tight. Refer to Figure 5. Wiring to Power Supply SAFETY WARNING RISK OF ELECTRICAL SHOCK. THIS RANGE HOOD MUST BE PROPERLY GROUNDED. MAKE SURE THIS IS DONE BY QUALIFIED ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. BEFORE CONNECTING WIR

Kobe Range Hoods CH-100 CH0030SQB

heruntergeladen wurde: 4Dateigröße: 1 mb    Hersteller: Kobe Range Hoods  
Kategorie: Ventilatoren

CH0030SQB CH0036SQB CH0042SQB CH0048SQB CH-100 SERIES – 18” HEIGHT INSTALLATION INSTRUCTIONS AND OPERATION MANUAL MANUEL D'INSTALLATION ET MODE D'EMPLOI INSTRUCCIONES DE INSTALACION Y MANUAL DE OPERACION [ENGLISH]................................................................................................................................. 1. [FRENCH]................................................................................................................................ 28. [SPANISH]....

Kobe Range Hoods CH7742SQ

heruntergeladen wurde: 7Dateigröße: 1 mb    Hersteller: Kobe Range Hoods  
Kategorie: Ventilatoren

Press either Speed Control button once (will start on Low speed) for fan control. See Fig. 4. 3. Press Speed Control button to cycle from QuietMode. through high speed. See Fig. 4. 4. Press Light Control button to turn light on. Turn Off: 1. Press Power Control button once (panel lights will flash for 10 seconds before power will completely shut off). 2. Press Power Control button twice (all power will shut off immediately). 3. If only lights are on, pressing Power Control button once will turn

Kobe Range Hoods CH8036SQ

heruntergeladen wurde: 0Dateigröße: 1 mb    Hersteller: Kobe Range Hoods  
Kategorie: Ventilatoren

2) When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hidden utilities. 3) Ducted hood must always be vented to the outside. a) Before servicing or cleaning unit, SWITCH POWER OFF AT SERVICE PANEL. b) Clean fan, optional filter and grease laden surfaces frequently. To reduce the risk of fire and to properly disperse air, make sure to vent air outside. DO NOT vent exhaust air into wall spaces, attics, crawl spaces or garages. NOTE - This warrant y i





Kategorien