Login:

New Buck Corporation 18

heruntergeladen wurde: 0Dateigröße: 660 kb    Hersteller: New Buck Corporation  
Kategorie: Kamine

CONTACT LOCAL BUILDING OR FIRE OFFICIALS CONCERNING RESTRICTIONS AND INSTALLATION INSPECTIONS IN YOUR AREA. MANUFACTURED BY NEW BUCK CORPORATION - SPRUCE PINE, NC 28777 THIS PRODUCT IS LISTED BY WARNOCK-HERSEY INTERNATIONAL, INC. TO THE UL STANDARD NO. 1482. REVISED AUGUST 2001 TABLE OF CONTENTS Important Instructions............................................................................................................…..3 SECTION I: Introduction.............................................

New Buck Corporation 32

heruntergeladen wurde: 5Dateigröße: 978 kb    Hersteller: New Buck Corporation  
Kategorie: Kamine

More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean. Page 17 GAS PRESSURE CHECK Check the inlet pressure to the burner to ensure that it is shown in the table below. NOTE: The pressure check point is located on the right side of the valve facing burner, for SIT Millivolt, and the left side for SIT Modulating. The appliance and its appl

New Buck Corporation 329

heruntergeladen wurde: 1Dateigröße: 2 mb    Hersteller: New Buck Corporation  
Kategorie: Kamine

. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s in- structions. • If you cannot reach your gas supplier, call the fire department. . Installation and service must be performed by a qualified installer,

New Buck Corporation 34

heruntergeladen wurde: 0Dateigröße: 2 mb    Hersteller: New Buck Corporation  
Kategorie: Kamine

The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean. 7 CR3329 CERAMIC LOG SET PLACEMENT, FOR MODEL 34 (1-L) (2) (4) (3) (1-R) WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specific

New Buck Corporation 384

heruntergeladen wurde: 17Dateigröße: 1 mb    Hersteller: New Buck Corporation  
Kategorie: Kamine

Fully open the manual shutoff valve. 8. Press in and turn knob on gas control counterclockwise to “PILOT” and continue pressing in the knob for (15) fifteen seconds. 9. With control knob pressed in push down (in) and release the ignitor button (ignitor button is located on the left hand side of the front of the appliance). This will light the pilot. If needed, keep repeating this step until pilot lights. 10. Keep control knob pressed in for (1) one minute after lighting pilot. After (1) minut

New Buck Corporation 42

heruntergeladen wurde: 5Dateigröße: 2 mb    Hersteller: New Buck Corporation  
Kategorie: Kamine

Rooms communicating directly with the space in which the appliances are installed, through openings not furnished with doors, are considered a part of the unconfined space. “WARNING: IF THE AREA IN WHICH THE HEATER MAY BE OPERATED IS SMALLER THAN THAT DEFINED AS AN UNCONFINED SPACE OR IF THE BUILDING IS OF UNUSUALLY TIGHT CONSTRUCTION, PROVIDE ADEQUATE COMBUSTION AND VENTILATION AIR BY ONE OF THE METHODS DESCRIBED IN THE NATIONAL FUEL GAS CODE, ANSI Z223.1/ NFPA 54, SECTION 5.3 OR APPLICABLE LOC

New Buck Corporation 42ZCBB

heruntergeladen wurde: 13Dateigröße: 981 kb    Hersteller: New Buck Corporation  
Kategorie: Kamine

CONSUMER: Retain this manual for future reference. New Buck Corporation P.O. Box 69 8000 Hwy. 226 South Spruce Pine, NC 28777 Revised: November 2004 TABLE OF CONTENTS Safety Information and Warnings.......................................................................................3 Installation...........................................................................................................................5 Firebox and Framing Dimensions (ZC) (FF)..............................

New Buck Corporation 74

heruntergeladen wurde: 0Dateigröße: 931 kb    Hersteller: New Buck Corporation  
Kategorie: Kamine

CONTACT LOCAL BUILDING OR FIRE OFFICIALS CONCERNING RESTRICTIONS AND INSTALLATION INSPECTIONS IN YOUR AREA. TESTED AND LISTED BY: ITS/WARNOCK HERSEY, MIDDLETON, WI MANUFACTURED BY NEW BUCK CORPORATION - SPRUCE PINE, NC 28777 5/2007 BUCKSTOVE BUCKSTOVE TABLE OF CONTENTS Important Instructions......................................................................................................... 2 SECTION I: Introduction ............................................................................

New Buck Corporation 81

heruntergeladen wurde: 5Dateigröße: 502 kb    Hersteller: New Buck Corporation  
Kategorie: Kamine

(A small weight on a string will serve as a plumb bob.) Mark the ceiling where the string is suspended to locate the center of the chimney. 2. After locating the center of the hole, install the ceiling support box, chimney, flashing and rain cap per the chimney manufacturer's instructions. 3. Now connect the stove and ceiling support box using #24 ga. minimum blued or black steel connector pipe. (DO NOT USE GALVANIZED PIPE.) Connect each section so the crimped end faces downward, and secure ea

New Buck Corporation 85

heruntergeladen wurde: 9Dateigröße: 574 kb    Hersteller: New Buck Corporation  
Kategorie: Kamine

Push up until the face of the outside air duct contacts the underside of the floor of the mobile home. For certain floor thickness, you may have to shorten the length of the outside air duct. 15. Secure the outside air duct to the floor using the four (4) #10 x 1" screws provided. See Figure 12. 26 RAIN CAP RAIN CAP Ceiling Exit (Using Close Clearance Listed Chimney) 1. Suspend a plumb bob from the ceiling above the unit so that the weight is hanging in the center of the flue exit. ( A sma





Kategorien