Anleitung New Buck Corporation, modell 81
Hersteller: New Buck Corporation Dateigröße: 501.5 kb Dateiname: 9e250247-a16c-4251-8b84-b08fcb82e5a0.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
(A small weight on a string will serve as a plumb bob.) Mark the ceiling where the string is suspended to locate the center of the chimney. 2. After locating the center of the hole, install the ceiling support box, chimney, flashing and rain cap per the chimney manufacturer's instructions. 3. Now connect the stove and ceiling support box using #24 ga. minimum blued or black steel connector pipe. (DO NOT USE GALVANIZED PIPE.) Connect each section so the crimped end faces downward, and secure each section to each other using at least 15 three (3) sheet metal screws or rivets. Next, install an optional New Buck Corporation chimney connector to the flue exit of the heater or you may use “Ell” brackets to fasten the pipe to the stove. 4. Install Single Wall Connector and chimney system per manufacturer’s written operating instructions. See manufacturer’s list of tested pipes in this manual. Figure 5 Figure 6 B. Wall Exit Into Metal Tee-Box 1. Mark the plumb line on the wall directly behind the center of the heater. (See Figure 6.) NOTE: When using #24 ga. minimum blue or black steel pipe maintain 18" between pipe and ceiling. 2. Place the vertical portion of the heater pipe and the elbow in position and project a point onto the plumb line level with the center of the elbow. 3. Measure up so there will be at least 1/4" rise per foot of horizontal connector pipe, 16 maintaining clearances to the ceiling as noted in Figure 6. This will give you the center of the hole for the chimney penetration. 4. After locating the center of the penetration, install the tee box and chimney as per the chimney manufacturer's specifications. 5. Connect the chimney collar to the tee-box using #24 ga. minimum blued or black steel connector pipe. (DO NOT USE GALVANIZED PIPE.) Connect each section so the crimped end faces downward, and secure each section to each other using three (3) sheet metal screws or rivets. C. Wall Exit Into Masonry (Using Single Wall Pipe) 1. Before connecting these units to a masonry chimney, determine that the masonry fireplace wall pass-through connector thimble meets the NFPA-211 Code and local building codes and is a minimum of 18" from the ceiling. If the connector thimble does not meet these codes, the pass-through connector must be modified. (See Figure 7.) CEILING-"^ CENTER LINE EE ELBGW ATTACH PIPE MOUNTING CLIPS TO HEATER AND CHIMNEY CONNECTER PIPE Figure 7 Connectors may pass through walls or partitions constructed of combustible material if the connector is: (a) Either listed for wall pass-through or is routed through a device listed for wall passthrough and is installed in accordance with the conditions of the listing. (b) Selected or fabricated in accordance with the conditions and clearances as stated in the NFPA-211 Code. Any unexposed metal that is used as part of a wall pass-through system and is exposed to flue gases shall be constructed of stainless steel or other equivalent material that will resist corrosion, softening, or cracking from flue gases at temperatures up to 1800° F. 17 NOTE: In addition, a connector to a masonry chimney shall extend through the wall to the inner face or liner but not beyond, and shall be firmly cemented to masonry. EXCEPTION: A thimble may be used to facilitate removal of the chimney connector for cleaning, in which case the thimble shall be permanently cemented in place with high-temperature cement. 2. Once the through-the-wall thimble codes are met, simply connect the chimney collar to the wall pass-through connector using #24 ga. minimum, blued or black steel connector pipe as follows: (a) Maintain 1/4" rise per foot (horizontal length) from the appliance to the chimney. (b) Connect each section so the crimped end faces downward or back toward the unit. (c) Secure each section to each other using at least three (3) sheet metal screws or rivets. (d) Use three (3) sheet metal screws to fasten pipe to connector collar on heater. D. Ceiling Exit-Close Clearance 1. Suspend a plumb bob from the ceiling above the unit so that the weight is hanging in the center of the flue exit. (A small weight on a string will serve as a plumb bob.) Mark the ceiling where the string is suspended to locate the center of the chimney hole. 2. After locating the center of the hole, install the ceiling support box, chimney flashing and rain cap. 3. Now connect the stove and ceiling support box using #24 ga. minimum blued or black steel connector pipe. (DO NOT USE GALVANIZED PIPE.) Connect each section so the crimped end faces downward, and secure each section to each other using at least three (3) sheet metal screws or rivets. Next, install an optional New Buck Corporation chimney connector to the flue exit of the heater or you may use “Ell” brackets to fasten the pipe to the stove. 4. Install Single Wall Connector and chimney system per manufacturer’s written operating instructions. See manufacturer's list of tested pipes in this manual. 18 CEILIN...