(Maximum 3/4” (19mm) thick). 1. Remove wiring compartment cover at end of heater where power supply cable is to enter. Determine desired mounting location (Figure 2), position heater to wall as intended and mark wall (or floor) at location where power supply is to enter heater. Figure. 2 2 2. Drill hole entry. Install location as approximately for connections. 3. If any other heater, refer accessory 4. Wireway - a. The wireway commercial baseboard heaters. vidual through rent loads. b. To gain r

Marley Engineered Products 2438

heruntergeladen wurde: 7Dateigröße: 279 kb    Hersteller: Marley Engineered Products  
Kategorie: Ventilatoren

(Fig. 10.) Install grommet in bracket (Fig. 10) and attach on each end of fan, using two of the short screws provided. Position fan over opening so that grommets are resting against center joist. Attach fan and brackets to center joist with the two long wood screws and flat washers. Do not crush grommet when tightening screws. FIG. 10 FIG. 11 GROMMET BRACKET GASKET STEP 6 - Attach side panels to fan as shown using remaining short screws and washers. (See Fig. 11.) Bottom panels should rest upon

Marley Engineered Products 2500

heruntergeladen wurde: 8Dateigröße: 93 kb    Hersteller: Marley Engineered Products  
Kategorie: elektrische Heizungen

Wire Size Circuit Breaker or Fuse Size (Copper) 0 thru 12 #14 15 amp 12.1 thru 16 #12 20 amp 16.1 thru 24 #10 30 amp NET VOLUMES OF WIRING COMPARTMENT DESCRIPTION CUBIC INCHES CUBIC CENTIMETERS Heater Only (Each Wiring Compartment) 14.96 241 Heater W/SP Thermostat 11.18 180 Heater W/DP Thermostat 11.18 180 Heater W/Heat-Cool Switch Receptacle 9.51 153 Heater W/Duplex Receptacle 11.18 180 Heater W/DP Disconnect Switch 11.18 180 Heater W/Power Relay 10.76 174 Heater W/Transformer Relay 2.93 47 Thi

Marley Engineered Products 3038R

heruntergeladen wurde: 2Dateigröße: 279 kb    Hersteller: Marley Engineered Products  
Kategorie: Ventilatoren

C. CAUTION: Incorrect wiring can cause motor failure and possible fire. Marley Engineered Products will not accept liability for damage resulting from incorrect wiring. FOLLOW ALL WIRING DIAGRAMS AND ALL INSTRUCTIONS CAREFULLY. D. This fan is designed to run on 120 volt A.C., 60 Hz power only. STEP 2 - The 3-speed control packed with this fan is used to operate fan from a remote wall location. Generally the best location is in the hallway near the fan. The control should be in sight of the fan.

Marley Engineered Products 3638R

heruntergeladen wurde: 36Dateigröße: 279 kb    Hersteller: Marley Engineered Products  
Kategorie: Ventilatoren

STEP 7—Stand assembly upright with motor at top and position shutter on outside of frame. Secure shutter with (8) wood or lag screws (number 12 x 1” preferred) through holes in shutter frame. See Fig. 3. STEP 8—To mount this attic fan in gable or wall, a box must be framed into wall construction as shown in Fig. 4. See wall opening in chart. FAN SIZE “A” & “B” DIMENSIONS WALL OPENING SIZE 30” 33 3/4” x 33 3/4” 34” x 34” 36” 39 3/4” x 39 3/4” 40” x 40” STEP 9—Insert frame containing fan and shutt

Marley Engineered Products 402A

heruntergeladen wurde: 12Dateigröße: 120 kb    Hersteller: Marley Engineered Products  
Kategorie: elektrische Heizungen

Place the heater on floor or other flat surface and insert plug into the proper wall outlet. WARNING ! BE CAREFUL NOT TO DIRECT THE AIRSTREAM AT DRAPERIES, FURNITURE, OR OTHER OBJECTS THAT COULD BE DAMAGED BY HEAT. DO NOT PLACE THE HEATER WHERE A SMALL CHILD MAY FALL OVER THE HEATER. DO NOT PLACE THE HEATER WHERE THE POWER CORD MAY BE WALKED ON, TRIPPED OVER, OR OTHERWISE SUBJECTED TO HARD USAGE. HEATER OPERATION Set thermostat to its full counterclockwise position. Plug the unit into a properly

Marley Engineered Products 482A

heruntergeladen wurde: 4Dateigröße: 120 kb    Hersteller: Marley Engineered Products  
Kategorie: elektrische Heizungen

THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED. AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT. MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES ARISING WITH RESPECT TO THE PRODUCT, WHETHER BASED UPON NEGLIGENCE, TORT, STRICT LIABILITY, OR CONTRACT. Some states do not allow the exclusion or limitation of

Marley Engineered Products 5200-2409-001

heruntergeladen wurde: 0Dateigröße: 589 kb    Hersteller: Marley Engineered Products  
Kategorie: Ventilatoren

PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE. Figure 1 Description Leading Edge air curtains produce a wall of continuously flowing air that acts as a thermal barrier against outside air and flying insects. These air curtains maintain interior conditioned temperature and prevent heated or cooled air from escaping through open doorways. They redu

Marley Engineered Products 562A

heruntergeladen wurde: 2Dateigröße: 120 kb    Hersteller: Marley Engineered Products  
Kategorie: elektrische Heizungen

9. A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or flammable liquids are used or stored 10. If this heater or its power cord become damaged or malfunc- tion in any way, unplug heater, discontinue use, and have unit repaired by a reputable repair service. 11. Heater is hot when in use. To avoid burns do not let bare skin touch hot surfaces. Use handle to move heater. 12. Do not use an extension cord with this heater. Do not cut off plug and w

Marley Engineered Products 898L

heruntergeladen wurde: 10Dateigröße: 59 kb    Hersteller: Marley Engineered Products  
Kategorie: Ventilatoren

It allows placement of the ventilator over the kitchen range and is operated by a wall switch away from the cooking area. Care must be taken at all times in handling the motor blade assembly, so as to avoid bending the blades. Model 898L is used for installation in frame houses. IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Do not use this fan with any Solid-State speed control device. 2. Use this unit only in