Industrial strength construction for long lasting reliability. Non-skid platform provides added support to unsteady patients. • 180° swivel head for side read • Weight capacity of 1,000lb/360 kg. Highest capacity! • Motion-sensing weighing technology • Customizable 1'' backlit LCD display • Displays fractions, lb/oz, decimals in standard; decimals in metric • User-friendly menu screen • Clock with date and time • Keypad Entry, BMI, Manual Tare, Zero, Auto-Off, Auto-Hold, Reweigh, Hold/Re
If Sensor cord from mattress becomes disconnected from control unit while in Auto mode, alarm will sound. 3.2 MANUAL MODE Mattress inflation level user determined by Comfort Adjust (-, +) setting. The indicator adjacent to the icon will light while manual mode is active. 3.3 FLOAT MODE all cells within mattress will be uniformly inflated when this icon is illuminated. 3.4 AP MODE. (Alternating Pressure) Adjacent cells within mattress will be alternately inflated and deflated in this mode. The in
Only qualified medical service personnel should attempt to repair this device. A Service Manual is available for use by qualified personnel. For assistance contact your local dealer. If additional assistance is needed, contact the Graham Field Health Products technical service department. Domestic Customers: Toll Free: 1-800-347-5678 Fax: 1-800-726-0601 1.0 Warranty The Control Unit is warranted free of defects in material and workmanship for a period of two (2) years. The Mattress is warranted
In addition, some models may be used in emergency situations. In an emergency situation, be sure to contact a physician or EMS immediately. 4 WARNING: DO NOT reuse plastic crush gaskets (fire risk). Set-Up (Yoke Style) • Inspect the cylinder following the instructions of your gas supplier. Be sure to purge the cylinder valve seat of debris. • Inspect the regulator for oil or grease. If either is visible, DO NOT use the regulator. • Be sure the sealing washer is in place on the inlet of the r
Turn the cylinder off and turn the regulator on to relieve any built-up pressure. Try tightening the regulator to the cylinder and opening the cylinder again. If this does not help, shut the system down again and contact a service representative. NEVER attempt to repair a regulator or cylinder yourself. • Adjust the flow rate setting by turning the knob clockwise until the desired setting shows in the window. • If the cylinder pressure falls below 300 PSI, exchange the cylinder for a full one.
If the toilet seat riser is not properly assembled and installed, personal injury and damage to the toilet seat riser could result. WARNING: If components are damaged or missing, contact your dealer immediately. DO NOT use substitute parts. Use only Lumex replacement parts. Non-Lumex replacement parts could cause personal injury and damage to the toilet seat riser. WARNING: This product has a weight limit of 300 lb. WARNING: GF Health Products, Inc. assumes no responsibility for any damage or in
9. Place a washer and wing nut on the end of the long bolt that protrudes through the bottom of the toilet bowl. hardware 6482R-2 assembled 6482ER-2 assembled “R” on armrest socket locking button toilet seat riserarmrest right armrest shown installed (shown upside down) mounting holes 6482ER-2, one arm attached (shown upside down) boltwasherswingnut 6486R-2-INS-LAB-RevA11 10. Use a Phillips or blade screwdriver, whichever is appropriate, to turn the bolt clockwise until toilet seat riser and toi