Login:
Stimmen - 2, Durchschnittliche Bewertung: 3.5 ( )

Anleitung Graham Field, modell ALTADYNE 753004

Hersteller: Graham Field
Dateigröße: 88.27 kb
Dateiname: ProductAdditionalInfoItemOriginal675.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Only qualified medical service personnel should attempt to repair this device. A Service Manual is available for use by qualified personnel. For assistance contact your local dealer. If additional assistance is needed, contact the Graham Field Health Products technical service department. Domestic Customers: Toll Free: 1-800-347-5678 Fax: 1-800-726-0601 1.0 Warranty The Control Unit is warranted free of defects in material and workmanship for a period of two (2) years. The Mattress is warranted free of defects in material and workmanship each for a period of one (1) year. The Control Unit, and Mattress are warranted under the terms and conditions of the Graham Field Health Products warranty in place at the time of purchase. A copy of the warranty is available upon request. Graham Field Health Products disclaims all implied warranties including, but not limited to, the implied warranties of merchantability and of fitness for a particular purpose. Control Units may be returned to Graham Field Health Products for servicing. Contact Graham Field Health ProductsCustomer Service for return authorization prior to return. Please contact Graham Field Health Products Customer Service if you have warranty questions. Toll Free: (800) 347-5678, (800) 726-0601 2 Lumex® AltaDyne AutoFloat Indications for Use/Safety Precautions Attention, consult accompanying document 2.0 Symbols Type BF equipment Dangerous voltage Protective earth 3.0 Indications for Use This device is intended to assist in treating and preventing pressure ulcers. 4.0 Contraindication Air support treatment is not recommended when spinal stability is a concern. 5.0 Safety Precautions Review the following SAFETY PRECAUTIONS prior to using the AltaDyne Auto Float™ System. DANGER Risk of electric shock. Refer servicing to qualified service personnel. WARNING • Disinfect the AltaDyne AutoFloat system between patient installations. Failure to disinfect may risk cross- contamination and infection. • Check patient at least every 8 hours or once per shift, to assure proper system operation. • Deflate mattress before performing CPR or CPR will be ineffective. CAUTION • Some medical conditions may not respond to treatment of this type. Patient’s skin condition should be inspected regularly. Consult physician if any redness or skin breakdown occurs. • For grounding reliability, plug only into a properly grounded outlet. • Make certain all mattress straps are secured to the bed frame to prevent mattress from sliding and causing patient injury. • Lumex® mattresses are not intended to be AND DO NOT FUNCTION AS a patient fall safety device. SIDE RAILS MUST BE USED WITH THE LUMEX® MATTRESS TO PREVENT FALLS, unless determined unnecessary based on the facility protocol or the patient's medical needs as determined by the facility, IN WHICH CASE THE USE OF OTHER SUITABLE PATIENT SAFETY MEASURES ARE RECOMMENDED. • Use minimal layers of sheeting and incontinence pads. Too many layers between the patient’s skin and the support surface will reduce the effectiveness of the system. • Do not pull linens tightly over mattress. Tight sheets can cause “hammocking” and reduce effectiveness of treatment. • Medical Electrical Equipment requires special precautions regarding EMC and should be installed and put into service according to the EMC information provided in the accompanying documents. • Portable and RF communications equipment can affect medical electrical equipment. • Do not use in the presence of smoking materials or open flame. Air flowing through the air mattress will support combustion. 3 Lumex® AltaDyne AutoFloat Description/Features 6.0 Description The AltaDyne AutoFloat is a portable air flotation system with on-demand alternating low pressure treatment, designed to provide benefit to patients suffering from, or at risk of, developing pressure ulcers. The system, consisting of a Control Unit and Air Flotation Mattress with it’s Top Sheet, is designed to provide pressure management and patient comfort. The Control Unit inflates and maintains the Mattress to user-selected settings, and can also provide on demand alternating low pressure treatment if desired. Featuring Active Sensor Technology, the system automatically adjusts the Mattress to the optimal fill level ensuring complete flotation pressure management. Mattress The Mattress base consists of twenty transverse air cells constructed of a low shear nylon. Each of the individual cells is a minimum of eight inches tall (inflated height) and spatially oriented above a two inch convoluted foam base. The Active Sensor Mattress utilizes 4 specialized air cells in the center region of the Mattress which contain active sensors for detecting patient flotation level. Covering the entire Mattress assembly is a low-friction, low-shear producing, vapor permeable, nylon Top Sheet. The Top Sheet surface creates a membrane impermeable to liquids, air and bacteria though still permeable to water vapor. Quilted onto the base of the Mat...

Dieses Handbuch ist für folgende Modelle:
Camping - ALTADYNE 753003 (88.27 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien