60462 Internet: Other Europe: +44 1592 782612 Copyright © 2005 by Andrew Corporation Table of Contents Introduction How to Use This Manual Getting Started Installation Procedures Operation Preventive Maintenance Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Proprietary Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Slippage can cause the corresponding assembly to move, causing antenna misalignment. When designated, the A-325 hardware should be tightened according to the following tensioning procedure. NOTE: Tensioned bolts are for final connections only and should not be loosened for reuse. Lubricate the bolt threads with the provided stick wax to reduce friction. Insert the bolt, and add a flat washer—if required. Do not allow wax under the flat washer. Add the nut, and finger tighten. After the connectio
• Canada • Mexico: 1-800-255-1479 Orland Park, IL U.S.A. 60462 Internet: U.K.: 0800 250055 • Other Europe: +44 1592 782612 Printed in U.S.A. April 11, 2006 Copyright © 2003 by Andrew Corporation 11-APR-06 Rev E OMACS3000 List of Figures................................................................................................................................. 4 System Description .................................................................................................................
Any accumulated imbedded dirt, corrosion, grease, or oil deposits that require further cleaning may be removed with a bristle or wire brush and a cleaning solvent such as trichlorethylene or equal. After cleaning, allow cleaned parts to dry for 10 to 15 minutes before placing the equipment into operation. The frequency of inspection is contingent upon the user’s individual standards and the operational environment in which the earth station is located. However, a visual inspection of the earth s
The mount can be positioned manually or by using a crane; however, Andrew recommends that this procedure be performed using a crane to ensure speed and ease of installation. Figure 3-2: Crate Unpacking As stated previously, the pedestal ground mount installation process can be conducted manually or by using a crane. The following steps provide the necessary procedures for installing the ground mount assembly using a crane. 16 Installation Procedures Step 1 Step 2 Step 3 Step 4 Carefully remove t
60462 Internet: Other Europe: +44 1592 782612 Copyright © 2005 by Andrew Corporation Table of Contents Introduction How to Use This Manual Getting Started Installation Procedures Operation Preventive Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Proprietary Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Be certain both feed rotation limit switch arms are not distorted and ride centrally on the actuating cam to open their corresponding limit switch. • Inspect the azimuth and elevation jackscrew boots for security of attachment at both ends, for abrasion, tears, cuts, brittleness and other damage that may expose the jackscrew to the environment (water, dust, etc.). Minor repairs can be made with RTV108 silicone rubber sealant. • Visually inspect the feed window for dirt and the feed, feed support
for #3 rebar and drilled .218 for ..4-20 self tapping grounding screw and galvanized or painted for protection. 1 - Pole and foundation design based on the following criteria: a) Uniform building code exposure B or C and 1.5 stability factor. b) Vertical soil pressure of 2000 pounds per square foot. BubbleLevelGround PoleMust BeVertical InAll DirectionsWithin .19 InchesAt Top (0.3.) c) Lateral soil pressure of 400 pounds per square foot. d) Concrete compressive strength of 2500 pounds per square
A World of Solutions. International Telephone: +1-708-873-2307 Fax: +1- 708-349-5444 Internet: DO NOT DISCARD CONTENTS The product in this packaging was placed in the market after August 13, 2005. Its components must not be discarded with normal municipal or household waste. Contact your local waste disposal agency for recovery, recycling, or disposal instructions. HARDWARE SORTER HARDWARE SORTER DATE DESCRIPTION REV. 1/06 ECN9007200 Rev A 8/06 ECN9007484 Rev B VSAT ANTENNA/MOUNT/LNB LIMITED TWE
• Use 7/8 by 2-1/4 in (57 mm) hardware Note: Angles are attached edge out with flat of angle facing inward. 301786 Figure 16 Align panning frame/azimuth pivot assembly by swinging panning frame through its entire arc. Slightly snug panning frame/pivot assembly hardware, and again swing panning frame through its entire arc. Continue this procedure until mounting hardware is ready for tensioning. Note: Do not tighten hardware on 301786/201022 azimuth pivot assemblies at this time. 21 Installation