6. Do not use a unit with a damaged power cord. The power cord should not be altered, jerked, bundled, weighed down, pinched, or tangled. Such actions could result in electric shock or fire. To unplug the unit, be sure to pull the plug, not the cord, and do not jerk the cord. 7. To reduce the risk of electric shock, do not touch the plug or control switch with damp hands. 8. The GREEN ground wire in the factory-installed power cord is connected to a screw on the rear panel where the cord enters
Make sure that none have fallen into the storage bin. 2. The storage bin is for ice use only. Do not store anything else in the storage bin. 3. Keep the area around the icemaker clean. Dirt, dust, or insects in the unit could cause electrical damage to the equipment or harm to individuals. A. Cleaning and Sanitizing Instructions Perlick recommends cleaning and sanitizing this unit at least once a year. More frequent cleaning and sanitizing, however, may be required in some existing water conditi
Allow the water tank to drain, then reconnect the suction tube. 28) Repeat steps 24 through 27 two more times to rinse thoroughly. 29) Clean the storage bin liner, door liner, and door gasket with a neutral cleaner. Rinse thoroughly after cleaning. 30) Move the control switch to the "ICE" position to start the automatic icemaking process. Fig. 39 Separator Rail Slope 29 B. Maintenance IMPORTANT This icemaker must be maintained individually, referring to the instruction manual and labels provided
Alterations could result in electric shock, injury, fire, or damage to the unit. 3 I. Specifications A. Construction Top Panel Ice Making Mechanism Scoop Holder Front Panel Control Switch Louver Bin Control Thermostat Bulb Slope Magnet Catch Door Power Cord B. Nameplate Rating PERLICK ICE MAKER MODEL NUMBER H50IMS-R SERIAL NUMBER AC SUPPLY VOLTAGE 115-120/60/1AMPERES 3.4 AMPS DESIGN PRESSURE HI-240PSI LO-120PSI REFRIGERANT 134a 4.2 oz. MOTOR-COMPRESSOR THERMALLY PROTECTED APPROVED FOR OUTDOOR US
See Fig. 3. If you are leaving the door right-hinged, skip to step 7. If you would like to reverse the door hinges, proceed to step 6. (3) Fabrication of Overlay Panel Fabricate the overlay panel as outlined in the applicable specification on the previous pages and the instructions below. 1) Rout a channel at the bottom of the overlay panel to the proper dimensions. See "(C) Routed Area" in the specification diagram and Fig. 1. 2) Drill six 1/4" diameter (hardwood may require slightly larger dia
Read the warnings contained in this booklet carefully as they give important information regarding safety. Please retain this booklet for any further reference that may be necessary. CONTENTS Important Safety Information ................................................................................................. 3 I. Specifications ..................................................................................................................... 4 A. Construction..........................
Beer pump panels should not be installed with a height of greater than 5 feet from the cooler floor. A height greater than 5 feet will potentially cause flow issues and require system re-balancing. (Note: Make sure panel is level and pumps are in the vertical position). ¦ Drill 9/64” pilot holes in cooler wall. Use fasteners provided in installation kit to mount the beer pump panel to the cooler wall. ¦ Push CO2 supply line over barbed CO2 supply inlet. (See diagram on page 3). Position clamp ov
Adjust the Secondary Air/ CO2 regulator located on the beer pump panel to a minimum operating pressure of 10 psig. Smart Coupler Probe Valve Lever Positions ¦ Connect the coupler to a regulated water supply with pressure less than 30 psig. Note: Pump damage may occur with pressure higher than 30 psig. ¦ Open the water supply. Then open probe valve on Perlick Smart coupler to the 45° position. See figure 2. The beer pump will slowly pump up the beer line in the trunk housing to set psig. Note: If
Z2149A Rev. 10.11.06 4 5 Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice. Diagram #2 – Beer Pump Form No. Z2149A Rev. 10.11.06 6 Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice. Diagram #3 – Cleaning Diagram Form No. Z2149A Rev. 10.11.06 Cleaning Instructions General Information ¦ The cleaning of beer lines with the new integral flow reversal
¦ Cut a piece of CO2 tubing (red 9/16” vinyl tubing) and push one end onto barbed CO2 outlet to Keg Couplers (See diagram on page3). Position clamp over joint and tighten. Push the other end over the barbed gas inlet on the Perlick Smart Coupler. Position clamp over joint and tighten. Important Notes . CAUTION: If using CO2 as a pressure supply for pumps, pump exhaust must be vented to a well ventilated area to avoid possible asphyxiation. . Never use a single keg to supply more than one beer pu