1 THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE. Important Safety Advice: When using electrical appliances, basic precautions should be followed to reduce the risk of fire, electric shock, and injury to persons, including the following : • If the appliance is damaged, check immediately with the supplier before installation and operation. • Do not use this heater in the immediate surroundings of a bath, shower or swimming pool. • Do not use outdoors. • This
Concept Remote Blower CONTENTS WARNING 3 CHARACTERISTICS 5 INSTALLATION 8 USE 13 MAINTENANCE 14 2 EN READ THESE INSTRUCTIONS BEFORE YOU START INSTALLING THIS RANGEHOOD READ AND SAVE THESE INSTRUCTIONS WARNING: - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE: Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium setting. Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepe
Dieses Modell ist zur permanenten Wandbefestigung in einer Mindesthohe von 300mm konzipiert. Die Wandhalterung ist in waagerechter Position zu befestigen und das Kabel muss – wie in Abb. 1 gezeigt – nach rechts unten am Heizgerat verlaufen. Um einen optimalen Blick auf das Brennstoffbett zu erhalten wird ein Abstand von 600mm zwischen unterer Abschlusskante des Heizgerats und dem Fu.boden empfohlen (siehe Abb. 2 zu empfohlenen Abmessungen zur Befestigung). Um optimale Sicht zu gewahrleisten – ma
(6.8 m) Recommended standard fittings 3-1/4" x 10" (8.3 cm x 25.4 cm) to 6" (15.2 cm) = 4.5 ft. (1.4 m) 6" (15.2 cm) to 3-1/4" x 10" (8.3 cm x 25.4 cm) = 1 ft. (0.3 m) 3-1/4" x 10" (8.3 cm x 25.4 cm) to 6" (15.2 cm) 90° elbow = 5 ft. (1.5 m) 6" (15.2 cm) to 3-1/4" x 10" (8.3 cm x 25.4 cm) 90° elbow = 5 ft. (1.5 m) 90° elbow = 5 ft. (1.5 m) 45° elbow = 2.3 ft. (0.8 m) 6" wall cap = 0 ft. (0 m) WARNING Installation steps Excessive Weight Hazard Use two or more people to move and install downdraft
When making the electrical connection, cut a 1 1/4" hole in the wall. A hole cut through wood must be sanded until smooth. A hole through metal must have a grommet. WARNING -TOREDUCETHERISKOFFIREORELECTRIC SHOCK, do not use this fan with any solid-state speed control device. WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. Before
For best results, use no more than three 90° elbows. Make sure that there is a minimum of 24" of straight duct between elbows if more than one is used. Do not install two elbows together. If you must elbow right away, do it as far away from the hood's exhaust opening as possible. 45. Elbow 3.0 feet 90. Elbow 5.0 feet 90. Flat Elbow 12.0 feet Wall Cap0.0 feet FIGURE 2 9 Feet Straight Duct 9.0 feet 2 - 90. Elbows 10.0 feet Wall Cap 0.0 feet Total System 19.0 feet FIGURE 3 Version 03/08- Page 5 INS
FIGURES 1 and 2 show vertical and horizontal installations for this unit. FIGURE 3 shows recirculating installation. TheMagnumrequires6"roundductwork. Toensure that the blower performs to its highest possible capacity, ductwork should be as short and straight as possilbe. WARNING! BEFORE MAKING ANY CUTS OR HOLES FOR INSTALLATION, DETERMINE WHICH VENTING METHOD WILL BE USED AND CAREFULLY CALCULATE ALL MEASUREMENTS. CALCULATE THE DUCTRUN LENGTH The ductrun should not exceed 35 equivalent feet if d
The homeowner must keep these instructions for future reference and for local electrical inspectors' use. Observe all governing codes and ordinances. Proper installation is your responsibility. Make sure you have everything necessary for correct installation. It is the responsibility of the installer to comply with the clearances specified. To avoid damage to motor bearings and impellers, keep drywall spray, construction dust, etc. away from the remote blower. Before installing remote blower, re
In a ducted application, this rangehood can be vented through the wall or ceiling. To vent through a wall, a 90° elbow is used. When installed ductless, the rangehood vents out of grates on the sides of the chimney. Ductless installations require a Ductless Conversion Kit, available from your dealer. WARNING! BEFORE MAKING ANY CUTS OR HOLES FOR INSTALLATION, DETERMINE WHICH VENTING METHOD WILLBE USED AND CAREFULLY CALCULATE ALL MEASUREMENTS. FIGURE 1RANGEHOOD ASSEMBLY PLAN THE INSTALLATION The P
Label which cable is the 120-volt supply wire and which is the exterior blower cable. Now Start... Cover countertop or cooking surface with a thick, protective covering to prevent damaging them. 2-3/4" 5-15/16" (7.0 cm) (15.1 cm) wall A B 17-5/16" 11" (27.9 cm) 5/16" (7.9 mm) (40.0 cm) dia. dia. 4-holes hood size A B 36" (91.4 cm) 31-7/16" (79.9 cm) 15-23/32" (39.9 cm) 48" (121.9 cm) 43-7/16" (110.3 cm) 21-23/32" (55.2 cm) 1. Mark the locations of four 5/16" (7.9 mm) dia. holes and an 11" (27.9