Login:
heruntergeladen wurde: 4   Dateigröße: 204 kb   Hersteller: Craftsman  
Kategorie: Pumps
@name

To prevent air from leaking out of the tank between uses, turn the RED ON/OFF KNOB clockwise to the closed position. Storage STORING YOUR PORTABLE AIR TANK Turn the RED ON/OFF KNOB CLOCKWISE to the OFF position when storing your air tank. Failure to remove condensation will cause the tank to rust prematurely. Always drain the tank of all air after the last use for the day and before repairing or removing any component parts. Point the safety pressure relief valve AWAY FROM YOUR BODY when releasi

heruntergeladen wurde: 8   Dateigröße: 204 kb   Hersteller: Craftsman  
Kategorie: Pumps
@name

If this Portable Air Tank is used for commercial or rental purposes, this warranty applies for only 90 days from the date of purchase. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Sears, Roebuck and Co., Dept. 817WA, Hoffman Estates, IL 60179 Important Safety Instructions and Guidelines The information listed below should be read and understood by the operator. This information is given to protect the user while operating and st

heruntergeladen wurde: 4   Dateigröße: 2 mb   Hersteller: Craftsman  
Kategorie: Pumps
@name

HAZArD risk FrOM NOise WHAT CAN HAPPeN HOW TO PreveNT iT • Under some conditions and dura• Always wear certified safety equiption of use, noise from this product ment: ANSI S12.6 (S3.19) hearing may contribute to hearing loss. protection. SAVE THESE INSTRUCTIONS FOR FUTURE USE N014212 8 - ENG GLOSSARYGLOSSARY Become familiar with these terms before operating the unit. CFM: Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measure of air delivery. PSIG: Pounds per square inch

heruntergeladen wurde: 11   Dateigröße: 1 mb   Hersteller: Craftsman  
Kategorie: Pumps
@name

(1) The model number which can be found on the tabel on the rear of the air tank. (2) The code number which can be found on the foil tabel on the rear of the air tank. (3) The Manufacturers Number (MFG.,.) {ASME Code Compressors onty) is located on the metst date plate which is welded onto the backside of the air tank. (This data plate is painted the same cotor as the tank.) (4) The Motor Manufacturers name which is mocated on the motor tabel or specification plate. (5) The Motor Mfg. number-ats

heruntergeladen wurde: 10   Dateigröße: 1 mb   Hersteller: Craftsman  
Kategorie: Pumps
@name

The exhaust valve remains closed. On the upstroke of the piston, air is compressed. The intake valves close and compressed air is forced out through the exhaust valve, through the outlet tube, through the check vatve and into the air tank. Working air is not available until the compressor has raised air tank pressure above that required at the air outlet. Check Vatve: When the air compressor is operating, the check valve is "open", allowing compressed air to enter the air tank. When the air comp

heruntergeladen wurde: 6   Dateigröße: 1 mb   Hersteller: Craftsman  
Kategorie: Pumps

Install the regulator on the end of the manifold using the short pipe hippie. The arrow on the bottom of the regulator must point away from the manifold in order for the regulator to function properly'. Next, install the gauge, adapter and plug in the regulator. The ptug is supplied with the regulator. BREAK= N PROCEDURES ° the minimum wire size is t2 gauge (AWG}. Sears #9 83606, 12 gauge x 50' extension cord is available at your local Sears Service Center. (Wire size increases as gauge number d

heruntergeladen wurde: 0   Dateigröße: 719 kb   Hersteller: Craftsman  
Kategorie: Pumps
@name@name

2. Make sure the outlet being used has the same configuration as the grounded plug. DO NOT USE AN ADAPTER. See illustration. Plug Grounded Outlets Grounding Pin 3. Inspect the plug and cord before each use. Do not use if there are signs of damage. 4. If these grounding instructions are not completely understood, or if in doubt as to whether the compressor is properly grounded, have the installation checked by a qualified electrician. Risk of Electrical Shock. IMPROPER GROUNDING CAN RESULT IN ELE

heruntergeladen wurde: 3   Dateigröße: 492 kb   Hersteller: Craftsman  
Kategorie: Pumps
@name@name

(1) The Model Number can be found on the maintenance label on top of the motor shroud or on the bar code label on the rear of air tank. (2) The Date Code Number can be found on the bar code label on the rear of the air tank. (3) The Serial Number can be found on the bar code label on the rear of the tank. (4) The Tank Registration Number is located on the metal data plate which is welded onto the backside of the air tank. (This data plate is painted the same color as the tank.) Retain these numb

heruntergeladen wurde: 14   Dateigröße: 946 kb   Hersteller: Craftsman  
Kategorie: Pumps
@name@name

HAZARD WARNING: Risk of explosion or fire What Could Happen How To Prevent It It is normal for electrical contacts within the motor and pressure switch to spark. Always operate the compressor in a well ventilated area free of combustible materials, gasoline, or solvent vapors. If electrical sparks from compressor If spraying flammable materials, locate come into contact with flammable compressor at least 20 feet away from vapors, they may ignite, causing fire or spray area. An additional length

heruntergeladen wurde: 3   Dateigröße: 364 kb   Hersteller: Craftsman  
Kategorie: Pumps
@name

The following schedule is geared toward a consumer whose compressor is used in a normal working environment on a daily basis. If necessary, the schedule should be modified to suit the conditions under which your compressor is used. The modifications will depend upon the hours of operation and the working environment. Air compressors used in an extremely dirty and/or hostile environment will require a greater frequency of all maintenance checks. Oil Changing For changing the pump oil, be sure to





Kategorien