Login:
heruntergeladen wurde: 8   Dateigröße: 3 mb   Hersteller: EMI  
Kategorie: Pumps
@name

Rome, NY 13440 An ISO 9001-2000 Certified Company P/N# 240006021 Rev. 1.3 [05/07] WLCA/WLHA High Wall Evaporator 2 WLCA/WLHA HIGH WALL High Efficiency EVAPORATOR installation, operation and maintenance MANUAL P/N 240006021, Rev. 1.3 [05/07] This manual is intended as an aid to a qualified service personnel for proper installation, operation, and maintenance of EMI AmericaSeries high efficiency evaporators. Carefully read these instructions before attempting installation or operation. Failure to

heruntergeladen wurde: 4   Dateigröße: 515 kb   Hersteller: EMI  
Kategorie: Pumps
@name

The system shall consist of a high wall mounted packaged evaporator section Model WLH12 and matching America Series outdoor unit Model S1H2. The units shall be made within North America. The units shall be listed by Intertek Testing Service (ITS) and beartheETLlabel.AllwiringshallbeinaccordancewiththeNationalElectricalCode(N.E.C.).Theunitsshallberated in accordancewithARI Standard 210/240and bear theARI label.The units shallbe manufacturedina facilitycertified toISO9001,whichisaninternationalsta

heruntergeladen wurde: 4   Dateigröße: 2 mb   Hersteller: EMI  
Kategorie: Pumps
@name

B [10/08] JOB NAME: PURCHASER: , ENGINEER: SUBMITTED TO: . SUBMITTED BY: UNIT DESIGNATION: SCHEDULE #: LOCATION: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] DATE:_ MODEL #: Manufacturer reserves the right to change these specifications at any time without incurring obligation. I g

heruntergeladen wurde: 7   Dateigröße: 5 mb   Hersteller: EMI  
Kategorie: Pumps
@name

Turn oFF PoWer SuPPlY FirST. Outdoor units may be cleaned or waxed if desired. Use a non-abrasive car wax. Panels should remain on the unit at all times. Service should be performed by a QUAli- FiED service agency only. All EMI products are subject to ongoing development programs so design and specifications may change without notice. Please consult the factory for more information. general reCommendaTionS Do not charge the straight cool units on cold days unless weighing in the charge. The heat

heruntergeladen wurde: 6   Dateigröße: 5 mb   Hersteller: EMI  
Kategorie: Pumps
@name

If below the chart value remove refrigerant. If below the limit line, remove refrigerant. Example (Using the 12,000 Btuh cooling chart): 1. Suction pressure is 65 psi. which equals 38° F on The R-22 Scale of the Low- Side gauge. 2. Suction line temperature taken at the unit is 70° F. 70° F minus 38° F equals 32° F superheat. Instructions: 1. Measure suction pressure and determine evaporator-refrigerant temperature on R-22 scale of low-side gauge. 2. Measure suction-line temperature on suction li

heruntergeladen wurde: 6   Dateigröße: 5 mb   Hersteller: EMI  
Kategorie: Pumps
@name

To access wiring diagram: 7multi-zone Heat Pump Condensing units a) Remove the four screws on the front panel of the unit and slide the panel down until the upper edge is free, then remove the panel. b) The wiring diagram is located on the inside of the front panel. wiring Diagram Common Suction Pressure Access Point HighPressure Reset (18 & 24) Vapor(Suction) Liquid eleCTriCal Wiring t2HB, t3HB, And t4HB InStAllAtIon InStructIonS SEctIon t2HB, t3HB, And t4HB InStAllAtIon InStructIonS SEctIon 5.

heruntergeladen wurde: 11   Dateigröße: 3 mb   Hersteller: EMI  
Kategorie: Pumps
@name

Maximumlengthallowed is 100 equivalent feet. • Avoid high traffic areas and prevailing wind locations. • Surface must be level. • Mount unit above typical snow levels. Ensure free flow of air through the unit. Air must not recirculate from discharge to intake. Air is drawn through the coil with side, or top discharged through the fan grille. A minimum 48” clearance is necessary for the condenser discharge. Intake (coil side) clearance is 12” minimum. Consider how power will be run to the unit fr

heruntergeladen wurde: 12   Dateigröße: 5 mb   Hersteller: EMI  
Kategorie: Pumps
@name

An ISO 9001-2000 Certified Company Rome, NY 13440 P/N# 240006458 Rev. B [10/08] EMI AMErIcA SErIES MultI-zonE HEAt PuMP condEnSIng unItS EMI AMErIcA SErIES MultI-zonE HEAt PuMP condEnSIng unItS inSTallaTion, oPeraTion and mainTenanCe manual This manual is intended as an aid to qualified service personnel for proper installation, operation, and maintenance of these EMI America Series multi-zone heat pump condensing units. Read the instructions thoroughly and carefully before attempting installati

heruntergeladen wurde: 22   Dateigröße: 3 mb   Hersteller: EMI  
Kategorie: Pumps
@name

The units are delivered precharged with refrigerant for the condenser coil and the evaporator. Charging of the field installed piping is required. Refer to the refrigerant charge table for the proper amount to be added for the applications interconect piping. Unit service valves are solid brass, for sweat connections. IMPORTANT: All systems require field charge adjustments. Refer to the "Refrig- erant Charge Tables" for proper weight charge and to the supplied “Field Charging Charts" for proper

heruntergeladen wurde: 9   Dateigröße: 2 mb   Hersteller: EMI  
Kategorie: Pumps
@name

A [06/08] SpecificationS and performance Heat pump Nominal Capacities: 9,000 and 12,000 Btuh dEsCrIPtIon EMI offers the finest high capacity dual zone outdoor units in the ductless split market, the S2H High Capacity Condensing Unit. The S2H allows the installation of two circuits from a single outside location when space or aesthetic requirements limit the use of locations. The S2H has easy access interconnect valves on the back of the unit and each zone is independent so no mixing of refrigera





Kategorien