Login:
heruntergeladen wurde: 7   Dateigröße: 3 mb   Hersteller: Honda Power Equipment  
Kategorie: Pumps

heruntergeladen wurde: 4   Dateigröße: 2 mb   Hersteller: Honda Power Equipment  
Kategorie: Pumps
@name

HONDA MOTOR CO., ITD RESERVES THE RIGHT TO MAKE CHANGES AT ANY TIME WITHOUT NOTICE AND WITHOUT INCURRING ANY OBLIGATION WHATEVER. NO PART OF THIS PUBLICATION MAY BE REPRODUCED WITHOUT WRITTEN PERMISSION. OWNER’S MANUAL FOR SAFE OPERATION ^WARNING • To prevent fire hazards and to provide adequate ventilation, keep the pump at least 3 ft away from buildings and other equipment during operation. • Do not place flammable materials, such as gasoline, matches etc., close to the pump while it is

heruntergeladen wurde: 6   Dateigröße: 550 kb   Hersteller: Honda Power Equipment  
Kategorie: Pumps
@name

check the fuel level. Use any regular grade automotive gasoline (unleaded gasoline is preferred) with a pump octane rating of 86 or higher. Never use an oil/gasoline mixture or dirty gasoline. Avoid getting dirt, dust or water in the fuel tank. CAUTION: Gasoline substitutes are not recommended; they may be harmful to the fuel system components. ^warning • Gasoline is extremely flammable and explosive under certain conditions. Refuel in a well ventilated area with the engine stopped. • Do n

heruntergeladen wurde: 12   Dateigröße: 2 mb   Hersteller: Honda Power Equipment  
Kategorie: Pumps
@name

Jhe use of replacement parts which are not of equivalent quality may damage the pump. 'V REGULAR SERVICE PERIOD x Perform at every indicated month or \ operating hour intervals, whichever occurs first. ITEM Daily First 1 month or 20 Hts. operating Every 3 months or 50 Hrs. operating Every 6 months or ISO Hrs. operating Every 1 year or 300 Hrs, operating Engine oil Inspection O Change O o Air cleaner element Inspection C Cleaning ' 0(1) Fuel filter cleaning o Spark p

heruntergeladen wurde: 6   Dateigröße: 550 kb   Hersteller: Honda Power Equipment  
Kategorie: Pumps
@name

The use of replacement parts which are not of equivalent quality may damage the engine. Maintenance Schedule \ REGULAR SERVICE PERIOD ITEM perform at every indicated monttTor^ operating hour interval, which > ever comes first. \ Each use First month or 20 Hrs. Every 3 months or 50 Hrs. Every 6 months or 100 Hrs. Every year or 300 Hrs. Engine oil Inspection o Change o O Air cleaner element Inspection o Cleaning °(1> Spark plug maintenance o Tappet clearance adjustme

heruntergeladen wurde: 8   Dateigröße: 547 kb   Hersteller: Honda Power Equipment  
Kategorie: Pumps
@name

Read and understand the Owner's Manual before operating the pump. Failure to do so could result in personal injury or equipment damage. ^WARNING 1 CONTENTS 1. SAFETY INSTRUCTIONS............................ 3 2. WARNING LABÊL LOCATION........................ 4 3. COMPONENT IDENTIFICATION ...................... 5 4. PREPARATION..................................... 6 5. STARTING THE ENGINE............................ 10 6. OPERATION....................................... 13 7. STOPPING T

heruntergeladen wurde: 8   Dateigröße: 996 kb   Hersteller: Honda Power Equipment  
Kategorie: Pumps
@name

2. Turn the engine switch to the OFF position. ENGINE SWITCH THROTTLE LEVER 3. Turn the fuel valve OFF. I FUEL VALVE NOTE: To stop the engine in an emergency, turn the engine switch to the OFF position. 7. 7. E The purpose of the maintenance and adjustment schedule is to keep the pump in the best operating condition. Inspect or service as scheduled in the table below. m Shut off the engine before performing any maintenance. If the engine must be run, make-sure the area is weli ventilated. The ex

heruntergeladen wurde: 7   Dateigröße: 713 kb   Hersteller: Honda Power Equipment  
Kategorie: Pumps
@name

All information in this publication is based on the latest product information available at the time of approval for printing. Honda Motor Co., Ltd. reserves the right to make changes at any time without notice and without incurring any obligation. The illustrations in this book are based on the WB20X unless otherwise noted. No part of this publication may be reproduced without written permission. This manual should be considered a permanent part of the pump and should remain with the pump if it

heruntergeladen wurde: 7   Dateigröße: 1016 kb   Hersteller: Honda Power Equipment  
Kategorie: Pumps
@name

4. Reinstall the air cleaner element and cover. AIR CLEANER ELEMENT AIR CLEANER COVER 3. 3. Recommended spark plug: BPRGES(NGK) W2OEPR-U(NlPPONDENS0) To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. 1. Remove the spark plug. The muffler becomes very hot during operation and remains hot for a while after stopping the engine. Be careful not to touch the muffler while it is hot. 2. Visually inspect the spark plug. Discard it if the insulator is cracked

heruntergeladen wurde: 8   Dateigröße: 714 kb   Hersteller: Honda Power Equipment  
Kategorie: Pumps
@name

No part of this publication may be reproduced without written permission. This manual should be considered a permanent part of the pump and should remain with the pump if it is resold. Pay special attention to statements preceded by the following words: mzm Indicates a strong possibility of severe personal injury or loss of life if instructions are not followed. CAUTION: Indicates a possibility of personal injury or equipment damage if instructions are not followed. NOTE: Gives helpful informati





Kategorien