Login:
heruntergeladen wurde: 30   Dateigröße: 485 kb   Hersteller: GE  
Kategorie: Pumps
@name@name@name

Date of Purchase: Installation: Current Readings at Startup: Single Phase: Three Phase – 1st Phase: 2nd Phase: 3rd Phase: Table of Contents SUBJECT PAGE Safety Instructions................................................................. 2 Description and Specifications ............................................. 2 Lifting of Pump ..................................................................... 2 Sliderail System .................................................................... 2 Pipin

heruntergeladen wurde: 15   Dateigröße: 485 kb   Hersteller: GE  
Kategorie: Pumps
@name@name@name

servicing pump. Electrical supply MUST match pump’s nameplate specifications. Incorrect voltage can cause fire, damage motor and voids warranty. Single phase motors are equipped with automatic thermal protectors which open the motor’s electrical circuit when an overload exists. This can cause the pump to start unexpectedly and without warning. Some models are equipped with a 3-prong grounded plug and MUST be used in a grounded 3-wire receptacle. DO NOT modify the plug or remove the ground prong.

heruntergeladen wurde: 26   Dateigröße: 485 kb   Hersteller: GE  
Kategorie: Pumps
@name@name@name

NOTICE: FOLLOW ALL SAFETY AND LIFTING INSTRUCTIONS PROVIDED IN THIS MANUAL. • Following the slide rail instructions, remove the pumping unit from the sewage containment area. UNIT MUST BE FLUSHED AND WARNING DISINFECTED, INSIDE AND OUT, PRIOR TO SERVICING. Biohazard can cause serious personal injury. MECHANICAL SEAL REPLACEMENT 1. Follow ALL instructions provided in the “DISASSEMBLY” section of this manual. 2. To gain access to the pump impeller and mechanical seal remove the four casing hex cap

heruntergeladen wurde: 10   Dateigröße: 100 kb   Hersteller: GE  
Kategorie: Pumps
@name

Circuit Amps 15 20 30 Recommended Protective Device 15 Amp Time Delay Fuse or Breaker 20 Amp Time Delay Fuse or Breaker 30 Amp Time Delay Fuse or Breaker Specification Created 8/02 Minimum Clearances: Front • Allow 4 inches in front of unit. When determining closet depth, note that plenum may protrude into closet up to 4 inches, depending on wall depth. Sides • Allow 3 inches on each side of unit. • For side access closets only: Allow 5 inches on the side where access is required. Platfo

heruntergeladen wurde: 8   Dateigröße: 100 kb   Hersteller: GE  
Kategorie: Pumps
@name

Circuit Amps 15 20 30 Recommended Protective Device 15 Amp Time Delay Fuse or Breaker 20 Amp Time Delay Fuse or Breaker 30 Amp Time Delay Fuse or Breaker Specification Created 8/02 Minimum Clearances: Front • Allow 4 inches in front of unit. When determining closet depth, note that plenum may protrude into closet up to 4 inches, depending on wall depth. Sides • Allow 3 inches on each side of unit. • For side access closets only: Allow 5 inches on the side where access is required. Platfo

heruntergeladen wurde: 13   Dateigröße: 100 kb   Hersteller: GE  
Kategorie: Pumps
@name

Circuit Amps 15 20 30 Recommended Protective Device 15 Amp Time Delay Fuse or Breaker 20 Amp Time Delay Fuse or Breaker 30 Amp Time Delay Fuse or Breaker Specification Created 8/02 Minimum Clearances: Front • Allow 4 inches in front of unit. When determining closet depth, note that plenum may protrude into closet up to 4 inches, depending on wall depth. Sides • Allow 3 inches on each side of unit. • For side access closets only: Allow 5 inches on the side where access is required. Platfo

heruntergeladen wurde: 5   Dateigröße: 94 kb   Hersteller: GE  
Kategorie: Pumps
@name

When determining closet depth, note that plenum may protrude into closet up to 4 inches, depending on exterior wall depth. Sides • Allow 3 inches on each side of unit. • For side access closets only: Allow 5 inches clearance to front of unit. Platform • An 8”-12” high, field-supplied platform is recommended for drain access. 230/208 Volt Line Cord Connected Units Power Connection Kit RAK3152 RAK3202 RAK3302 Heater KW 2.55/2.09 3.45/2.83 5.00/4.10 Min. Circuit Amps 15 20 30 Recommende

heruntergeladen wurde: 5   Dateigröße: 221 kb   Hersteller: GE  
Kategorie: Pumps
@name

When determining closet depth, note that plenum may protrude into closet up to 4 inches, depending on exterior wall depth. Sides • Allow 3 inches on each side of unit. • For side access closets only: Allow 5 inches clearance to front of unit. Platform • An 8”-12” high, field-supplied platform is recommended for drain access. 230/208 Volt Line Cord Connected Units Power Connection Kit RAK3152 RAK3202 RAK3302 Heater KW 2.55 3.45 5.00 Min. Circuit Amps 15 20 30 Recommended Protective De

heruntergeladen wurde: 4   Dateigröße: 94 kb   Hersteller: GE  
Kategorie: Pumps
@name

When determining closet depth, note that plenum may protrude into closet up to 4 inches, depending on exterior wall depth. Sides • Allow 3 inches on each side of unit. • For side access closets only: Allow 5 inches clearance to front of unit. Platform • An 8”-12” high, field-supplied platform is recommended for drain access. 230/208 Volt Line Cord Connected Units Power Connection Kit RAK3152 RAK3202 RAK3302 Heater KW 2.55/2.09 3.45/2.83 5.00/4.10 Min. Circuit Amps 15 20 30 Recommende

heruntergeladen wurde: 6   Dateigröße: 221 kb   Hersteller: GE  
Kategorie: Pumps
@name

When determining closet depth, note that plenum may protrude into closet up to 4 inches, depending on exterior wall depth. Sides • Allow 3 inches on each side of unit. • For side access closets only: Allow 5 inches clearance to front of unit. Platform • An 8”-12” high, field-supplied platform is recommended for drain access. 230/208 Volt Line Cord Connected Units Power Connection Kit RAK3152 RAK3202 RAK3302 Heater KW 2.55 3.45 5.00 Min. Circuit Amps 15 20 30 Recommended Protective De





Kategorien