|
Dieses Gerät hat auch andere Anweisungen:
Anleitung Zusammenfassung
HP 219239 BACK SIDE PN D9431-80204 6.181 X 11.811 DC 1682 ALA SP 85/2400 OM
Management Port
HP NetServer LPr Service
E Rear Panel
PCI Slot #3
G Specifications
Link LED
Information
PCI Slot #2
Network
Activity LED
See LED
Power Requirements
PCI Slot #1
definitions below
Electronic Support Services
100 Mbps LED
Operating Current
• Internet Web Page http://www.hp.com/go/netserver
100 VAC
5.3A
• Internet FTP ftp://ftp.netserver.hp.com
120 VAC
4.6A
• CompuServe Library GO HPPC
200/208 VAC 3.2A
• HP Navigator CD
220/230 VAC 2.8A
Support Questions
Voltage and Frequency
88 - 264VAC, 47-63Hz
• HP-Authorized Reseller
In-Rush Current
25A
• CompuServe Discussion Forum GO HPPC
Leakage Current in Rack 15mA
• US / Canada Phone Support 1-970-635-1000
Delayed Action Circuit Breaker
• Europe Phone Support (+31-20) 581-3330 (Netherlands)
Recommendations
HP has offices in over 100 countries. Check your local telephone
Mouse
Serial Port B
110/120 60Hz - NEMA AB1 Class 14B
directory.
Power Inlet
Ultra SCSI
Keyboard
Serial Port A
Monitor
Parallel Port
220/240 50Hz - IEC Type C for 16A circuits
Selected HP Accessories
Space Requirements
For other tested accessories, download the Order Assistant from
Rear Panel LED Definitions:
System Dimensions 3.5"H x 17.6"W x 28"D
the HP Web page.
Link
Steady green when the LPr's network adapter and the network
(8.9cm x 44.7cm x 71.1cm)
Rack Space
2 EIA units
Audience Assumptions
switch are properly connected and receiving power.
This Service Reference Label is for trained service personnel.
Activity
Rate of green flashes reflects network traffic to/from LPr's network adapter.
Rack Clearance
None required
Hewlett-Packard Company assumes you are qualified in the
System Weight
40 lbs (88 kg)
servicing of computer equipment and trained in recognizing
100 Mbps
Steady green indicates support of 100 Mbps transfers. Off for 10 Mbps transfers.
hazards in products with hazardous energy levels.
Air Conditioning Requirements
Electrostatic Discharge To avoid catastrophic or hidden
Maximum Heat Output 1041 BTU/hour
damage to components, wear a wrist strap and use a static-
Operating Temperature 41 to 95 degrees F
dissipative work surface connected to the chassis when
(5 to 35 degrees C)
handling components. Use an antistatic service kit, such as
F Control Panel
Power On/Off
Reset Switch Drive Activity LED
3M
® 8501/8502/8505 or equivalent.
Switch
Operating Humidity
20% to 80% RH
System Troubleshooting
Drive Error
LED
• Check LEDs at front and rear of system as shown in
H Memory
panels at left.
Reset
• Use only HP DIMMs.
• On power-up, a beep error code message may appear
Fan Failure
before the video display starts. Refer to the list of Beep
LED
• The LPr ships with 64MB and can support 1GB.
Codes in Information Assistant on your LPr On-Line
Power
Over-Temperature
Documentation CD.
On/Off LED
LED
• DIMMs may be installed in any combination in any
• If an error code appears during boot, place the HP Network
socket.
Navigator CD in the CD-ROM drive, attempt the boot and
Control Panel LED Definitions:
then press the ENTER key when the error code appears.
Power On/Off Steady green shows system power ON.
An explanation will appear on the screen.
• Check that the System Board is properly seated in the
Drive Activity
Flashes green to show access over embedded SCSI controller.
I Mass Storage
I/O Board.
Drive Error
Flashes red to indicate that one of the two drives in the hot-swap bays has failed and
must be replaced. Remove front bezel to check drive LEDs. Flashes yellow to predict
• Two hot-swap SCSI drive shelves support LVDS
Interrupt Sharing
drive failure or to indicate that the drive is running out of space. Use TopTools to
low-profile SCSI devices.
• Note that the embedded SCSI Controller and PCI Slot #3
determine cause.
share the same interrupt line. The operating system will
Over-
Flashes red when temperature is hazardous -- shut down and check for sources of over-
• Do not use HVD SCSI devices in the LPr.
distinguish the interrupt source, but performance will be
Temperature
temperature. Flashes yellow when temperature nears hazardous levels - check for
adversely affected.
source of over-temperature.
• Use single-ended SCSI devices on the SCSI bus
This information is subject to change without notice and is
outside of the LPr.
provided without warranty.
Fan Failure
Flashes red to indicate a fan failure - shut down gracefully and replace the fan.
©2000, Hewlett-Packard Company. All rights reserved.
Flashes yellow to indicate the start of a fan failure -- schedule shutdown and fan
• Be certain any external SCSI cable ends with proper
replacement.
termination and does not exceed 2.5 meters.
P/N: D9431-80204
For additional information, see other side.