Dieses Gerät hat auch andere Anweisungen:
Anleitung Zusammenfassung
LANs:
Client LAN
Any NIC that is HP and Microsoft approved. See Client LAN below.
For a SPOFless cluster, two D5013B NICs configured with AFT is
recommended.
Intra-cluster
Embedded NIC with crossover cable, or, configure as a VLAN through an
(Heartbeat) LAN
ethernet switch. See Intra-cluster LAN below.
Power source
Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS. Redundant power
distribution units (PDU’s) are strongly recommended.
System software:
Navigator version
L.18.02 or later
Operating System
Microsoft Windows 2000 Advanced Server
SPU
Model
HP NetServer LH 3000
Clock speed
733, 800, 933 MHz
No. of CPUs
2
BIOS version
4.06.21 PT or later (733 MHz)
4.06.24 PT or later (800, 933 MHz)
CPU cache
Any size
RAM
256 MB minimum. Must be HP.
No. of power supplies
2 standard, 3 required for redundancy, 4 for power cord redundancy.
Local storage
See Local Storage below.
I/O slot
Added cards may be installed in any appropriate slot, keeping in mind the
server’s default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, SE SCSI C, Embedded A, Embedded B, PCI-8,
PCI-7, PCI64-6, PCI64-5, PCI64-4, PCI64-3, PCI64-2, PCI64-1
M/S Certified
M/S Certified Configuration:
Configuration
P5 - Local Storage – NetRAID-1Si
P6 – Client LAN
P8 – Shared Storage- FC HBA
Booted from embedded DAC
Storage
Local
Controller
May use embedded SCSI, embedded DAC, NetRAID-3Si or NetRAID-1Si.
For SPOFless, recommend embedded DAC with drives in RAID-1 mirror,
or another fault tolerant RAID level.
Driver
For embedded SCSI, use sym_hi.sys from Windows 2000 Adv. Server CD
version 5.00.2134.1 or later.
For embedded DAC and NetRAID-xSi, use mraid35x.sys version 2.62
(Navigator L.18.04.5 or later).
Cabinets (Physical drive
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
location)
Storage/12), any number.
Disk drives
Must be HP (hot swap or fixed)
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids
Any
2
...Dieses Handbuch ist für folgende Modelle:
PC Desktops - HP NetServer LC 2000 (589.38 kb)
PC Desktops - HP NetServer LC 2000r (589.38 kb)
PC Desktops - HP NetServer LC II (589.38 kb)
PC Desktops - HP NetServer LC Plus (589.38 kb)
PC Desktops - HP NetServer LE (589.38 kb)
PC Desktops - HP NetServer LF (589.38 kb)
PC Desktops - HP NetServer LH 3/LH 3r (589.38 kb)
PC Desktops - HP NetServer LH 4/LH 4r (589.38 kb)
PC Desktops - HP NetServer LH 3000 (589.38 kb)
PC Desktops - HP NetServer LH 3000r (589.38 kb)
PC Desktops - HP NetServer LH (589.38 kb)
PC Desktops - HP NetServer LH 6000 (589.38 kb)
PC Desktops - HP NetServer LH 6000r (589.38 kb)
PC Desktops - HP NetServer LH II (589.38 kb)
PC Desktops - HP NetServer LH Plus (589.38 kb)
PC Desktops - HP NetServer LH Pro (589.38 kb)
PC Desktops - HP NetServer LM (589.38 kb)
PC Desktops - HP NetServer LP 1000r(1.13/1.26/1.40GHz) (589.38 kb)
PC Desktops - HP NetServer LP 1000r (589.38 kb)
PC Desktops - HP NetServer LP 2000r (589.38 kb)
PC Desktops - HP NetServer LP 2000r(1.13/1.26/1.40GHz) (589.38 kb)
PC Desktops - HP NetServer LPr (589.38 kb)
PC Desktops - HP NetServer LS (589.38 kb)
PC Desktops - HP NetServer LT 6000r (589.38 kb)
PC Desktops - HP NetServer LX Pro/LXe Pro (589.38 kb)
PC Desktops - HP NetServer LXr 8000 (589.38 kb)
PC Desktops - HP NetServer LXr 8500 (589.38 kb)
PC Desktops - HP NetServer LXr Pro8 (589.38 kb)
PC Desktops - HP NetServer LX (589.38 kb)
PC Desktops - HP NetServer LXr Pro (589.38 kb)