Login:
Stimmen - 0, Durchschnittliche Bewertung: 0 ( )

Anleitung HP, modell HP EVA3000 Disk Array

Hersteller: HP
Dateigröße: 119.49 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Dieses Gerät hat auch andere Anweisungen:

Anleitung Zusammenfassung


IMPORTANT NOTES AND WORKAROUNDS
This section identifies important notes and workarounds specific to the EVA3000/5000 hardware and
VCS software. Operating constraints for related software applications are included in the following
documents:
HP OpenView Storage Management Appliance Software release notes
HP StorageWorks Command View EVA release notes
HP StorageWorks Continuous Access EVA release notes
HP StorageWorks Business Copy EVA release notes
HP StorageWorks Replication Solution Manager release notes
Refer to Table 3 for links to the web sites for these products.
Any operating constraints pertaining to the host operating system can be found in the individual operating
system release notes. See "Supported operating system specifications" on page 3.
Upgrading in an HP Continuous Access EVA environment
The following restrictions apply when upgrading to VCS v4.004 on EVA3000/5000 storage systems
running Continuous Access EVA. This is only an overview of some of the steps involved in using HP
Continuous Access EVA. For more information on HP Continuous Access EVA, access the documentation
using the link in Table 3 on page 3.
• The upgrade process should be completed within one week (168 hours). The time window begins
with the upgrade of the first storage system. It concludes when all storage systems with a direct or
indirect Continuous Access relationship to the first storage system have been upgraded.
• Ensure that all storage systems involved in a DR relationship are fully functional with no failed
hardware.
• When using multiple Continuous Access relationships, make sure the following conditions are met:
• Not more than two VCS versions (either v3.028 or v4.004) are running.
• All EVA 4000/6000/8000 storage systems must be running only one version of XCS (V5.031
or later).
• If you need to update both VCS and XCS, do not attempt to upgrade both simultaneously.
Complete the upgrade of one family of firmware before upgrading the other.
• Suspend DR group replication for the duration of the upgrade process on the destination, even if
the intersite links are not available.
A code load of one control er forces both control ers on a storage system to reboot. If the control er being
upgraded is used as a destination for replication I/O, the source controller logs new I/O while the
destination controller reboots. After completing the firmware upgrade of the destination then resume
the replication to allow the controller to perform a merge. Wait for the merge to conclude after a code
load, or wait three minutes—whichever is longer—before performing the code load on any other storage
system in the relationship.
Disk Resource Pending Timeout for Microsoft® Windows® cluster configurations
If the disk resource count is greater than 8, HP recommends increasing the Pending Timeout parameter
for each disk resource from 180 seconds to 360 seconds. Increasing the timeout value helps maintain
continuous operation of disk resources across SAN perturbations.
To view and set the Pending Timeout parameter:
1. Open the Microsoft Cluster Administrator.
2. Select a disk group resource in the left pane.
3. Right click each disk resource in right pane, one at a time, and select Properties.
4. Select the Advanced tab from the Properties menu.
5. Locate the Pending Timeout value and change it to 360.
6


...

Dieses Handbuch ist für folgende Modelle:
Media Storage - HP StorageWorks EVA3000 EMEA Bundles (119.49 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien