Login:
heruntergeladen wurde: 11   Dateigröße: 8 mb   Hersteller: Amana  
Kategorie: Splitgeräte
@name

Providing you with new safety and reliability, the upgraded Stinger™ is capable of recovering all commonly used* CFC, HFC and HCFC refrigerants, including R-410A (Puron™). The unit is easy to operate and is ideal for evacuating both residential and light commercial systems. A simple purge system prevents cross contamination of refrigerants without changing hose. *Not for use with R-11, R-113 or R-123 BACHARACHISAU.S.MANUFACTURER2006-3800 Domestic 120V 2006-3801 Domestic 120V w/80% 2006-3807 Euro

heruntergeladen wurde: 6   Dateigröße: 2 mb   Hersteller: Amana  
Kategorie: Splitgeräte

IMPORTANT: DO NOT OVER BEND THE DUCT (SEE FIGURE) Adapter A Rawlplugs Skruer max 120CM min 30CM Fig.8 Fig.9 Fig.10 30cm 30cm Fig.7 7 Your window kit has been designed to fit most standard Vertical and horizontal window applications, However, it may be necessary for you to improvise/modify some aspects of the installation procedures for certain types of window. Please refer to Fig. 11 & Fig. 11a for minimum and maximum window openings. Window Kit Installation Horizontal window Window Slider Kit M

heruntergeladen wurde: 12   Dateigröße: 2 mb   Hersteller: Amana  
Kategorie: Splitgeräte
@name

2) Install the Flexible Exhaust Hose and the Adjustable Window Slider Kit as depicted in Fig.5 & Fig.5a Fig.5a Fig.5 NOTE: Step 2 is required only while using the cooling mode 3) Plug the unit into a 115V~60Hz grounded electrical outlet. 4) Make sure the water pump drain hose is correctly installed. .. 5) Press the on / off button to turn on the unit. Water pump drain hose Fig.6 1 BEFORE USE Dehumidifying and Cooling Operations O OOO - The operating range for cooling operating is 17 C-30 C/63 F-

heruntergeladen wurde: 16   Dateigröße: 1 mb   Hersteller: Amana  
Kategorie: Splitgeräte
@name

• Next menu – Displays Menu 2. Menu 2 • Main menu – Returns display to the Main menu. • System flush – Removes all oil and refrigerant from an A/C system. This mode is often used prior to retrofitting a system to R-134a. • Tank refill – Overrides the automatic tank refill function of the MAC2000 and transfers refrigerant from the external source tank to the internal storage tank. • System set-up – Sets up certain operating parameters in order for the MAC2000 to operate correctly. The set-up info

heruntergeladen wurde: 7   Dateigröße: 375 kb   Hersteller: Amana  
Kategorie: Splitgeräte

FAN DIR. Button Press to select up/down direction for fan. TURBO/MILD Press to be colder the unit. COVER Slide down to access most of the remote buttons. Slide down further to access the battery compartment. FAN Indicators FAN DIRECTION Indicators Lights to indicate Lights to indicate the the fan speed. fan direction. NATURAL Indicator Lights to indicate the speeds simulating a breeze. MODE Indicators (Auto/Quick/Cool/Fan/Dehumidifier/Heat) Lights to indicate the mode selected. AUTO TIMER Indica

heruntergeladen wurde: 7   Dateigröße: 375 kb   Hersteller: Amana  
Kategorie: Splitgeräte
@name

) 01.8.17 5:27 PM ...3.. BASIC ACCESSORIES This Installation section explains how and where to connect this new air conditioner. Please read make sure all accessories are included as shown below and read manual thoroughly. This Installation section is provided to assist the person knowledgeable in air conditioner installation and should not be installed by anybody who is not thoroughly familiar with this type of installation. Please contact a professional installer if necessary. ACCESSORIES SUPP

heruntergeladen wurde: 10   Dateigröße: 324 kb   Hersteller: Amana  
Kategorie: Splitgeräte
@name

3. Examine the filters and determine if they need to be cleaned or replaced. To clean filters, use a vacuum and clean off dust. Use water and mild soap also if necessary. NOTE: The filters should be changed every 6 months. If in a climate with cold winters, once a year is adequate. 4. Insert cleaned or new small filters (Deodorizing and Electrostatic) back into the unit. After putting the connection terminal into electric dust collector, insert the electric dust colloctor into the unit. CHANGING

heruntergeladen wurde: 6   Dateigröße: 260 kb   Hersteller: Amana  
Kategorie: Splitgeräte

However, if you still elect to use an extension cord, it is absolutely necessary that it will be a UL listed 3-wire grounding type appliance extension cord rated has a 3-blade grounding plug and a 3-slot receptacle that will plug into the appliance. The marked rating of the extension cord should be 125V/13A minimum for DWC-100C, DWC-100CS, DWC-121C, DWC-121CS and 250V/10A minimum for DWA-122C, DWA-122CS, DWA-150C, DWA-150CS, DWA-151C, DWA-151CS. WARNING : To avoid death, personal injury or prope

heruntergeladen wurde: 4   Dateigröße: 260 kb   Hersteller: Amana  
Kategorie: Splitgeräte

Using the hole in the top and bottom of each Window Kit Frame as a guide, secure Window Kit Frame in window sash and on the window sill. WINDOW SHUTTER WINDOW SASH WINDOW FRAME Screw (Type C) Screw (Type C) INNER WINDOW SILL 7 • Step 6 - Recheck Installation To be sure you have correctly installed your Room Air Conditioner, review the steps and make sure all of the parts are securely fastened in the window as the instructions show. A tight seal is essential. Read through the Use & Care manual to

heruntergeladen wurde: 5   Dateigröße: 260 kb   Hersteller: Amana  
Kategorie: Splitgeräte

of the right side. There are two kinds of method to install the drain cap. The rear side of the unit The first method is that the shape of hole like It is good for the household. The second method is that the shape of hole is like It is good for the shop. • DOOR VENT The door vent for the room air ventilation is lever type. If the door vent lever moves to the left, then close the vent and moves to the rght, then open the vent. Close Vent Open Drain Cap SEAL DRAIN Screw (Type D) Door Vent > 11 CA





Kategorien