heruntergeladen wurde: 22   Dateigröße: 856 kb   Hersteller: Bard  
Kategorie: Splitgeräte
@name

Models: WA611 WA701-B WA701-C WA702-A WA721 WALL MOUNTED PACKAGED AIR CONDITIONER INSTALLATION INSTRUCTIONS CONTENTS Getting Other Information and Publications For more information, contact these publishers: ..... 1 Wall Mount General Information Air Conditioner Wall Mount Model Nomenclature .... 2 Shipping Damage .................................................... 5 General ............................................................... 5 Duct Work .............................................

heruntergeladen wurde: 14   Dateigröße: 856 kb   Hersteller: Bard  
Kategorie: Splitgeräte
@name

All wiring must conform to the These "Minimum Circuit Ampacity" Refer to the National Electric (latest version), Article 310 for power CAUTION: When more than one filed conduit, the conductors Pay special attention 310 regarding Ampacity more than 3 conductors SHIPPING DAMAGE Upon receipt of equipment, the carton should be checked for external signs of shipping damage. If damage is found, the receiving party must contact the last carrier immediately, preferably in writing, requesting inspection

heruntergeladen wurde: 8   Dateigröße: 856 kb   Hersteller: Bard  
Kategorie: Splitgeräte
@name

Recycling the wall thermostat resets the manual lockout. Alarm Relay Output Alarm terminal is output connection for applications where alarm relay is employed. This terminal is powered whenever compressor is locked out due to HPC or LPC sequences as described. NOTE: Both high and low pressure switch controls are inherently automatic reset devices. The high pressure switch and low pressure switch cut out and cut in settings are fixed by specific air conditioner or heat pump unit model. The lockou

heruntergeladen wurde: 49   Dateigröße: 856 kb   Hersteller: Bard  
Kategorie: Splitgeräte
@name

Regardless the state of the low pressure switch, the contactor will reenergize after the delay on make time delay has expired. If the low pressure switch remains open, or opens again for longer than 120 seconds the unit will go into manual lockout condition and the alarm relay circuit will energize. Recycling the wall thermostat resets the manual lockout. Alarm Relay Output Alarm terminal is output connection for applications where alarm relay is employed. This terminal is powered whenever compr

heruntergeladen wurde: 16   Dateigröße: 856 kb   Hersteller: Bard  
Kategorie: Splitgeräte
@name

TAP RANGE 240V 253 -216 208V 220 -187 TABLE 5 THERMOSTAT WIRE SIZE Maximum Transformer Distance VA FLA Wire Gauge In Feet 55 2.3 20 gauge 18 gauge 16 gauge 14 gauge 12 gauge 45 60 100 160 250 TABLE 6 WALL THERMOSTAT AND SUBBASE COMBINATIONS Thermostat Subbase Predominate Features 8403-002 T87F3111 8404-003 Q539A1220 1 stage heat, 1 stage cool System: heat-off-cool Fan: auto-on 8403-041 T8034C --1 stage heat, 1 stage cool System: heat-off-cool Fan: auto-on 8403-019 T874C1760 8404-012 Q674A1001 1

heruntergeladen wurde: 9   Dateigröße: 707 kb   Hersteller: Bard  
Kategorie: Splitgeräte
@name

1791 Tullie Circle, N.E. Atlanta, GA 30329-2305 Telephone: (404) 636-8400 Fax: (404) 321-5478 NFPA National Fire Protection Association Batterymarch Park P.O. Box 9101 Quincy, MA 02269-9901 Telephone: (800) 344-3555 Fax: (617) 984-7057 Manufactured under the following U.S. patent numbers: 5,485,878; 5,301,744; 5,002,116; 4,924,934; 4,875,520; 4,825,936 Manual 2100-426 Page 1 WALL MOUNT GENERAL INFORMATION AIR CONDITIONER WALL MOUNT MODEL NOMENCLATURE MODEL NUMBER CONTROL MODULES J - Standard on

heruntergeladen wurde: 20   Dateigröße: 707 kb   Hersteller: Bard  
Kategorie: Splitgeräte
@name

The blank-off plate is available upon request from the factory and is installed in place of the fresh air damper shipped with each unit. CONDENSATE DRAIN A plastic drain hose extends from the drain pan at the top of the unit down to the unit base. There are openings in the unit base for the drain hose to pass through. In the event the drain hose is connected to a drain system of some type, it must be an open or vented type system to assure proper drainage. FIGURE 2 BLOWER DAMPER ASSEMBLY MIS-938

heruntergeladen wurde: 8   Dateigröße: 707 kb   Hersteller: Bard  
Kategorie: Splitgeräte
@name

Delay on Make (DOM) timing on power-up and after power interruptions is equal to 2 minutes plus 10% of Delay on Break (DOB) setting: 0.5 minute (30 seconds) DOB = 123 second DOM 1.0 minute (60 seconds) DOB = 126 second DOM 2.0 minute (120 seconds) DOB = 132 second DOM 3.0 minute (180 seconds) DOB = 138 second DOM 4.0 minute (240 seconds) DOB = 144 second DOM 5.0 minute (300 seconds) DOB = 150 second DOM During routine operation of the unit with no power interruptions the compressor will operate

heruntergeladen wurde: 15   Dateigröße: 500 kb   Hersteller: Bard  
Kategorie: Splitgeräte
@name

50 .50 B18 --. 50 .50 C00 --. 50 .50 C09 --. 50 .50 C15 --. 50 .50 C18 --. 50 .50 Manual 2100-324 Page 4 Manual 2100-324 Page 5 FIGURE 1 PREFABRICATED ROOF CURB SPECIFICATIONS HEAVY GAUGE GALVANIZED WITH WOOD NAILING STRIP, WELDED/LEAKPROOF ONE PIECE CONSTRUCTION – READY TO INSTALL MIS-1177 FIGURE 2 FIELD FABRICATED CURBING MIS-1178 CURB AND ROOF DETAILS *Duct Sizing Information Return Air Dimension “C” is length Supply Air Dimension “C” is length Return Air Dimension “H” is width Supply Sir Dim

heruntergeladen wurde: 12   Dateigröße: 500 kb   Hersteller: Bard  
Kategorie: Splitgeräte
@name

IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly size fuses and conductor wires in accordance with the National Electrical Code and all existing local codes. Manual 2100-324 Page 3 GENERAL INSTRUCTIONS IMPORTANT The equipment covered in this manual is to be installed by trained, experienced service and installation technicians. All duct work, supply and return ducts, must be properly sized for the design air flow requirement of the e