Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.3 ( )

Anleitung Amana, modell DSB-F154LH

Hersteller: Amana
Dateigröße: 323.57 kb
Dateiname: 369c8abb-b466-46ec-9286-33ee855aba8d.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


3. Examine the filters and determine if they need to be cleaned or replaced. To clean filters, use a vacuum and clean off dust. Use water and mild soap also if necessary. NOTE: The filters should be changed every 6 months. If in a climate with cold winters, once a year is adequate. 4. Insert cleaned or new small filters (Deodorizing and Electrostatic) back into the unit. After putting the connection terminal into electric dust collector, insert the electric dust colloctor into the unit. CHANGING/CLEANING THE AIR FILTERS To change or clean the two black air filters, follow the procedures below: 1. Open the indoor unit’s cover and remove both black air filters by bending them slightly backward and the lifting out. 2. Remove the two small filters (Deodorizing and Electrostatic) from the indoor unit. After removing the connection terminal of electric dust collector, remove the electric dust collector. (LH/PH/AH Model Only) 3. Examine the filters and determine if they need to be cleaned or replaced. To clean filters, use a vacuum and clean off dust. Use water and mild soap also if necessary. NOTE: The filters should be changed every 6 months. If in a climate with cold winters, once a year is adequate. 5. Insert cleaned or new black filters back into the unit. 4. Insert cleaned or new small filters (Deodorizing and Electrostatic) back into the unit. After putting the connection terminal into electric dust collector, insert the electric dust colloctor into the unit. (Only DSB-F154LH/154PH/154AH) CautionWhen you remove the electric dust collector, you must remove the power plug. INSTALLING THE REMOTE BRACKET To install the remote bracket, insert one of the 2 supplied screws into top hole of the bracket and into the wall. Level the remote bracket and insert the other screw into the bottom hole. Insert the remote controller when not using it. 14 CARE AND MAINTENANCE warning • Make sure the AC cord is unplugged and the unit is off before cleaning. • Do not use water on the unit to clean it. This is a shock hazard and the unit can be damaged. Clean the casing and front of the indoor unit with a vacuum brush or wipe with a clean damp cloth. • NEVER USE Solvents, harsh chemicals or hot water to clean the unit. • Some metal edges on the unit are sharp. Be careful when cleaning or handling. • Internal parts in the outdoor unit may need cleaning or routine maintenance from time to time. Consult your local service center for more details. AFTER THE SEASON: • Operate the fan, then dry the indoor unit. • Shut off the indoor unit and then unplug it from the wall. • Clean the air filters. • Cover the outdoor unit with the supplied cover; this is very important to protect this unit. BEFORE THE SEASON: • Make sure the air filters are clean. • Make sure the inlet and outlet on the indoor and outdoor units are not blocked by obstructions. • Make sure the unit is grounded. Consult a serviceman for help. PRECAUTIONS: • Do not use this unit for animal or plant storage. • In a lightning or thunder storm, immediately unplug it from the wall. 15 TROUBLESHOOTING GUIDE Before requesting service, please refer to the chart below for possible solutions: SYSPTOMS POSSIBLE CAUSE POSSIBLE SOLUTIONS No power. Power failure. Restore the power Line voltage too low. Contact electrician to install new outlet. Unit is unplugged or not completely Insert plug all the way. plugged in. Unit is off. Turn unit on. Batteries in remote are weak or dead. Replace remote’s batteries. EMERGENCY/REMOTE Slide EMERGENCY/REMOTE switch is not set to REMOTE. to REMOTE. The compressor does When the unit is first plugged in Wait 3 minutes for the unit to operate. not turn on. and turned on, the compressor (no cool air at cooling) will delay turn on for 3 minutes. (no heat air at heating) If the unit is turned off and then Wait 3 minutes for the unit to operate. immediately back on, the compressor will delay for 3 minutes. The air filter(s) is dirty or clogged. Clean or replace filter(s). A door or window is open. Shut door or window. There is an obstacle in front of Remove obstacle. intake or indoor unit. The temperature has been set Check and reset if necessary. improperly. Strange sounds occur. During operation, especially after This is normal. turning it on or off, refrigerant flows inside the unit. Strange smells occur. The fan is bringing out the The smell should go away shortly. smells of the carpet, walls, etc. No remote operation. Batteries are weak, dead or Replace batteries. inserted improperly. Remote is out of range. Move closer to unit. Remote not aimed at sensor. Aim remote at sensor. There is an obstruction between Remove obstruction. unit and remote. 16 INSTRUCTION OF INSTALLATION Below is an overview for the connection of the Indoor unit to the Outdoor unit. OVERVIEW This appliance must be installed according to national power supply acquirement. Drain Hose Ground Wire (Not Supplied) Gas side piping Oxygen tubeConnecting cable Liquid side piping Drain Hos...

Dieses Handbuch ist für folgende Modelle:
Splitgeräte - DSB-F154LH (323.57 kb)
Splitgeräte - DSB-F154LH (323.57 kb)
Splitgeräte - DSB-F154LH (323.57 kb)
Splitgeräte - DSB-F154LH (323.57 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien