Login:
heruntergeladen wurde: 8   Dateigröße: 284 kb   Hersteller: DCS  
Kategorie: Kochfelder
@name

2). Lever F in position A (Fig. 3). In the extraction mode the outlet venting hose must be 100mm in diameter. If the venting hose runs horizontal it must be slightly slanted upwards (about 10°) to ensure the air is vented easily from the kitchen to the outside. If the hood is to vent out into the open air through an external wall, you need a telescopic wall box (optional extra). Wall box and venting hoses are available via your AEG Stockist or AEG Spare Parts. Flame retardant venting hose is

heruntergeladen wurde: 6   Dateigröße: 97 kb   Hersteller: DCS  
Kategorie: Kochfelder
@name

A minimum distance of 100 mm. must be left between the side edges of the hob and any adjacent cabinets or walls. The minimum distance combustible material can be fitted above the hob in line with the edges of the hob is 420 mm. If it is fitted below 420 mm. a space of 50 mm. must be allowed from the edges of the hob. The minimum distance combustible material can be fitted directly above the hob is 700 mm. 650 mm 420 mm 420 mm 100 mm 50 mm 50 mm 55 mm 600 mm 700 mm 420 mm 100 mm 420 mm50 mm 55 mm

heruntergeladen wurde: 0   Dateigröße: 169 kb   Hersteller: DCS  
Kategorie: Kochfelder
@name

• P.O. Box 863 • Buffalo, NY 14240 • 716.875.6680 or 1.800.DENI.VAC (1.800.336.4822) • Fax: 716.875.6969 • ©2008 Keystone Manufacturing Company, Inc.

heruntergeladen wurde: 2   Dateigröße: 539 kb   Hersteller: DCS  
Kategorie: Kochfelder
@name

For more severe soiling, use a liquid scouring cream. Always clean the steel in the direction of the steel finish. To ensure that the steel retains its shine, it is recommended that you use a polishing agent for stainless steel on a regular basis. Always polish in the direction of the steel finish (cross-wise). Never use steel wool, metal sponges or other abrasive cleaning agents. The ceramic glass griddle The glass griddle must be cleaned each time it has been used. 1. Pour water onto the glass

heruntergeladen wurde: 2   Dateigröße: 532 kb   Hersteller: DCS  
Kategorie: Kochfelder
@name

For unit combinations, a reinforcement beam must be used between each unit. Min. 47 mm Reinforcement beams 10 It is not necessary to attach the reinforcement beam to the work top surface, as it is held in place by a specially designed moulding, which is incorporated in the hob units flanges. The units externally measured length 145 mm: Cooker hood 290 mm: Two-zone ceramic-top electric hob Two-burner gas hob Grill Fryer Wok 580 mm: Four-zone ceramic-top electric hob Four-burner gas hob 725 mm: Fo

heruntergeladen wurde: 0   Dateigröße: 314 kb   Hersteller: DCS  
Kategorie: Kochfelder
@name

• You will need an original AEG KF20 activated carbon filter for the filtering function. (See Special Accessories). • Fix the deflector using 4 screws O 3,5x6.5 mm. Fig. 2. • Optionally, the position of the chimney elements can be changed. When using the hood in the filter version the chimney must be fixed at the top, with the air outlet grill at the side. 52 Fig. 2 Bedienung der Dunsthaube • The hood is fitted with one motor having several speed. Turn the hood on a few minutes before you start

heruntergeladen wurde: 2   Dateigröße: 314 kb   Hersteller: DCS  
Kategorie: Kochfelder
@name

France Senlis +33 (0) 44 62 29 29 Germany Nurnberg +49 (0) 911 323 2600 Italy Pordenone +39 (0) 1678 47053 Sweden Stockholm +46 (0) 8 738 7910 UK Slough +44 (0) 1753 219899 Technic Details Models 2490 D 2460 D Dimensions -extractor ver (in cm): Height 68-113 68-113 Width 89,8 59,8 Depht 45 45 Dimensions - filter version (in cm): Height 67,5-122,5 67,5-122,5 Width 89,8 59,8 Depht 45 45 Maximum absorbed power: 195 W 195 W Motor absorption: 1 x 155 W 1 x 155 W Lighting: 2 x 20W 2 x 20W Lenght of th

heruntergeladen wurde: 0   Dateigröße: 431 kb   Hersteller: DCS  
Kategorie: Kochfelder
@name

Plug in the appliance. Turn on the electricity supply. Electrical connection WARNING: THIS APPLIANCE MUST BE EARTHED. All external wiring must comply with the IEE Regulations for the Electrical Equipment of Buildings. The electrical supply can be by either a plug and socket or a permanently wired connection via a double - pole switch. Should the plug (where supplied) not fit the socket in your home, it should be removed and replaced with a suitable plug. Note: If a moulded plug is fitted which i

heruntergeladen wurde: 0   Dateigröße: 404 kb   Hersteller: DCS  
Kategorie: Kochfelder
@name

• To dismount proceed in reverse order. • Always specify the hood model code number and serial number when ordering replacement filters. This information is shown on the registration plate located on the inside of the unit. • The activated carbon filter can be ordered from the AEG technical assistance service. Afb. 4 Warning • Failure to observe the instructions on cleaning the unit and changing the filters will cause a fire hazard. You are therefore strongly recommended to follow these instruct

heruntergeladen wurde: 22   Dateigröße: 404 kb   Hersteller: DCS  
Kategorie: Kochfelder
@name

Guarantee conditions Guarantee Conditions AEG offer the following guarantee to the first purchaser of this appliance. 1. The guarantee is valid for 12 months commencing when the appliance is handed over to the first retail purchaser, which must be verified by purchase invoice or similar documentation.The guarantee does not cover commercial use. 2. The guarantee covers all parts or components which fail due to faulty workmanship or faulty materials. The guarantee does not cover appliances where d