Login:
heruntergeladen wurde: 7   Dateigröße: 3 mb   Hersteller: Honda Power Equipment  
Kategorie: Pumps

heruntergeladen wurde: 12   Dateigröße: 2 mb   Hersteller: Honda Power Equipment  
Kategorie: Pumps
@name

Jhe use of replacement parts which are not of equivalent quality may damage the pump. 'V REGULAR SERVICE PERIOD x Perform at every indicated month or \ operating hour intervals, whichever occurs first. ITEM Daily First 1 month or 20 Hts. operating Every 3 months or 50 Hrs. operating Every 6 months or ISO Hrs. operating Every 1 year or 300 Hrs, operating Engine oil Inspection O Change O o Air cleaner element Inspection C Cleaning ' 0(1) Fuel filter cleaning o Spark p

heruntergeladen wurde: 8   Dateigröße: 2 mb   Hersteller: Honda Power Equipment  
Kategorie: Pumps
@name

At maximum throttle position, the pump will deliver the highest output volume. Moving the throttle lever toward the idle position will decrease the output volume of the pump. Recoil Starter Grip Pulling the starter grip operates the recoil starter to crank the engine for starting. MAXIMUM THROTTLE 10 CONTROLS & FEATURES FEATURES Oil Alert® System The Oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the

heruntergeladen wurde: 4   Dateigröße: 2 mb   Hersteller: Honda Power Equipment  
Kategorie: Pumps
@name

HONDA MOTOR CO., ITD RESERVES THE RIGHT TO MAKE CHANGES AT ANY TIME WITHOUT NOTICE AND WITHOUT INCURRING ANY OBLIGATION WHATEVER. NO PART OF THIS PUBLICATION MAY BE REPRODUCED WITHOUT WRITTEN PERMISSION. OWNER’S MANUAL FOR SAFE OPERATION ^WARNING • To prevent fire hazards and to provide adequate ventilation, keep the pump at least 3 ft away from buildings and other equipment during operation. • Do not place flammable materials, such as gasoline, matches etc., close to the pump while it is

heruntergeladen wurde: 10   Dateigröße: 1 mb   Hersteller: Honda Power Equipment  
Kategorie: Pumps
@name

This will close the valves, so moisture cannot enter the engine cylinder. Return the starter rope gently. STORAGE PRECAUTIONS If your pump will be stored with gasoline in the fuel tank and carburetor, it is important to reduce the hazard of gasoline vapor ignition. Select a well-ventilated storage area away from any appliance that operates with a flame, such as a furnace, water heater, or clothes dryer. Also avoid any area with a spark-producing electric motor, or where power tools are operate

heruntergeladen wurde: 5   Dateigröße: 1 mb   Hersteller: Honda Power Equipment  
Kategorie: Pumps
@name

. . . . . . . . . . . . . . . . 23 Normal use . . . . . . . . . . . . . . . . . . . . 23 PUMP OPERATION Pump Preparation Connect the Suction Hose Use a commercially available hose, hose connector, and hose clamps. The suction hose must be reinforced, non-collapsible wall or wire braided to prevent suction collapse. Keep the pump as close to the liquid to be pumped as possible. Avoid bends and sharp turns. Pump performance is best when the pump is not far above the liquid level and the hose is ke

heruntergeladen wurde: 10   Dateigröße: 1 mb   Hersteller: Honda Power Equipment  
Kategorie: Pumps
@name

After drying, fill with engine oil up to the specified level. * Clean more frequently if pump is operated in a dusty area. ELEMENT WARNING ★ Never use gasoline or low flash point solvents for cleaning the air cleaner element. A fire or explosion could result. EVERY I 00 HOURS CHANGE ENGINE OIL CLEAN FUEL FILTER CLEAN SPARK PLUG AND CHECK GAP O * Wash removed parts in high flash point solvent, dry them thoroughly and install securely. Turn the fuel valve ON and check for leaks. CHECK FU

heruntergeladen wurde: 6   Dateigröße: 1 mb   Hersteller: Honda Power Equipment  
Kategorie: Pumps
@name

о m ALL INFORMATION. ILLUSTRATIONS, DIRECTIONS AND SPECIFICATIONS INCLUDED IN THIS PUBLICATION ARE BASED ON THE LATEST PRODUCT INFORMATION AVAILABLE AT THE TIME OF APPROVAL FOR PRINTING. HONDA MOTOR CO., LTD RESERVES THE RIGHT TO MAKE CHANGES AT ANY TIME WITHOUT NOTICE AND WITHOUT INCURRING ANY OBLIGA TION WHATEVER. NO PART OF THIS PUBLICATION MAY BE REPRODUCED WITHOUT WRITTEN PERMISSION. OWNER’S MANUAL © HONDA MOTOR CO., LTD. 1982 m FOR SAFE OPERATION 'IK'WARNING • To prevent fire haza

heruntergeladen wurde: 9   Dateigröße: 1 mb   Hersteller: Honda Power Equipment  
Kategorie: Pumps
@name

16 DISCHARGE HOSE INSTALLATION ...................................................18 PRIMING THE PUMP............................................................................19 STARTING THE ENGINE .....................................................................20 SETTING ENGINE SPEED....................................................................22 STOPPING THE ENGINE .....................................................................23 SERVICING YOUR PUMP....................

heruntergeladen wurde: 10   Dateigröße: 1 mb   Hersteller: Honda Power Equipment  
Kategorie: Pumps
@name

This is no cause for concern. If spark knock or pinging occurs at a steady engine speed, under normal load, change brands of gasoline. If spark knock or pinging persists, see an authorized Honda servicing dealer. NOTICE Running the engine with persistent spark knock or pinging can cause engine damage. Running the engine with persistent spark knock or pinging is misuse, and the Distributor's Limited Warranty does not cover parts damaged by misuse. 28 SERVICING YOUR PUMP ENGINE OIL LEVEL CH





Kategorien