They are designed for use within the Black & Decker Air System's pressure range. OTHER MAKES MAY NOT WITHSTAND USE AT 65 psi. 10. PREVENT accidental starting. MAKE SURE the switch is in the “OFF" position before plugging in the cord. 11. NEVER “HORSEPLAY." High pressure air is dangerous. Don’t direct air flow toward yourself or others. 12. UNPLUG compressor when not in use, when cleaning and when changing attachments. Avoid accidental starting . . . make sure switch is off before plugging in
Mineral spirits may also be called paint thinner, varnish thinner, Varsol or no*odor thinner. Steel wool, abrasive cleaners, such as kitchen cleanser or metal scrapers may damage the surface of the compressor housing. Do not use gasoline, lacquer thinner, turpentine, acetone, dry cleaning fluids or other strong solvents on the compressor housing. The compressor is an oil-less unit incorporating materials which do not use oil as a lubricant. You’ll never need to oil the compressor . and will al
Like any other electrically powered device, If it is not used properly it may cause electric shock. Never operate the compressor outdoors when it is raining or in wet conditions. Never operate compressor with protective covers removed or damaged. Repairs attempted by unqualified personnel can result in serious injury or death by electrocution. Any electrical wiring or repairs required on this product should be performed by authorized service center personnel in accordance with national and local
Cut-In Pressure: While the motor is off, air tank pressure drops as you continue to use your accessory. When the tank pressure drops to a certain low level the motor will restart automatically. The low pressure at which the motor automatically restarts is called “cut-in” pressure. Cut-Out Pressure: When an air compressor is turned on and begins to run, air pressure in the air tank begins to build. It builds to a certain high pressure before the motor automatically shuts off - protecting your air
To Drain Tank 1. Set the Auto/On/Off switch to "OFF". 2. Turn regulator knob counterclockwise to set the outlet pressure to zero. 3. Remove the air tool or accessory. 4. Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring. 5. Drain water from air tank by opening drain valve (counter-clockwise) on bottom of tank. NOTE: Tilt tank forward to drain tank completely. Water will condense in the air tank. If not drained, wa
10 641915-00,FSCP200 Compressor 3/14/06 7:31 AM Page 11 OPERATION Know Your Air Compressor READ THIS INSTRUCTION MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Description of Operation Become familiar with these controls before operating the unit. Auto/On/Off Switch: Set switch in AUTO/ON position to provide automatic power to the pre
If you can.t find the answer or do not have access to the internet, call 1-800-544-6986 from 8 a.m. to 5 p.m. EST Mon. -- Fri. to speak with an agent. Please have the catalog number available when you call. SAVE THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE. VEA EL ESPANOL EN LA CONTRAPORTADA. INSTRUCTIVO DE OPERACION, CENTROS DE SERVICIO Y POLIZA DE GARANTIA. ADVERTENCIA: LEASE ESTE INSTRUCTIVO ANTES DE USAR EL PRODUCTO. Cat. # VEC012C Form # 90550870 Aug. 2009Copyright © 2009 Black & Decker Pri
Check the battery charge level by pressing the battery status button. The LED charge status display will indicate the level of battery charge. When only one red LED lights, recharge the unit. When the battery is overly discharged and if the green LED is lit when the charger is plugged in, this indicates the battery is at a high impedance stage. In this event, recharge the unit and leave the unit on charge for a period of 48hrs before using the unit. Notes: This unit is delivered in a partially c
You cannot overcharge the unit using the AC charging method. • All On/Off switches should be in the OFF position when the unit is charging or not in use. Make sure all switches are in the OFF position before connection to a power source or load. 3 90550871 Vec012CBD EN SP.qxp:VEC012CBD_ManualEN_080907 8/21/09 11:04 AM Page 4 • Do not use any accessory that is not recommended or provided by the manufacturer. • This system is designed to be used only on vehicles with a 12 volt DC battery system. D
IMPORTANT SAFETY INSTRUCTIONS WARNING: This product or its power cord contains lead, a chemical known to the State of California to cause cancer and birth defect or other reproductive harm. Wash hands after handling. WARNING: BURST HAZARD: Do not use the unit for charging dry-cell batteries that are commonly used with home appliances. These batteries may burst and cause injury to persons and damage property. Use the unit for charging/boosting a LEAD-ACID battery only. It is not intended to suppl