heruntergeladen wurde: 10   Dateigröße: 1 mb   Hersteller: Goodman Mfg  
Kategorie: Pumps
@name

2 Product Specifications ............................................................ 3 Expanded Cooling Data .......................................................... 4 Expanded Heating Data........................................................20 Airflow Data .......................................................................... 23 Auxiliary Heating Data.......................................................... 24 Heat Kit Electrical Specs.................................................

heruntergeladen wurde: 5   Dateigröße: 977 kb   Hersteller: Goodman Mfg  
Kategorie: Pumps

10.3 Antifreeze To avoid the risk of the freezing in the external section of the heating system (i.e. the flexible hoses, condenser and circulating pump within the heat pump casing) in the event of power failure during winter months, a suitable domestic heating system antifreeze should be used. This is added to the system water when finally filling the heating system. Full instructions are supplied with the system antifreeze, but immediate information can be obtained from and IMPORTANT As with a

heruntergeladen wurde: 11   Dateigröße: 977 kb   Hersteller: Goodman Mfg  
Kategorie: Pumps
@name

The COP data given above is based on 7.C ambient air and 35.C water temperature. This information should be used as guidance only and notto estimate the COP at other temperatures. ! NOTE Figure 2-5: Grant HPAW65 Figure 2-8: Grant HPAW130 Figure 2-6: Grant HPAW85 Figure 2-7: Grant HPAW110 Figure 2-9: Grant HPAW155 2.5 Pump Curves Pump Head (metres) Pump Head (metres) 6 5 4 3 2 1 0 Wilo-Classic Star 0 0.5 1 1.5 2 3) Flow (m3/h) Flow (m3/h) Star-RS15/6.25/6 2.6 Heat Pump Operating Sequences Pump OF

heruntergeladen wurde: 7   Dateigröße: 977 kb   Hersteller: Goodman Mfg  
Kategorie: Pumps

When tracing a fault code, use the table of fault codes on page 32 to help you. As often as not, it will be a wire that has become loose or disconnected. Check all wires for security before calling our helpline for assistance. There are 6 sensors in total. The ATC have black tails and the BTC have blue tails. The resistance/temperature tables for the ATC and BTC sensors are given in Figures 13-2 and 13-3. 6. The pressure gauge on the side of the heat pump measures refrigerant pressure not water

heruntergeladen wurde: 4   Dateigröße: 977 kb   Hersteller: Goodman Mfg  
Kategorie: Pumps

They are not intended to describe complete systems, nor any particular system. It is the responsibility of the system designer, not Grant Engineering UK Ltd., to determine the necessary components for and configuration of the particular system being designed including any additional equipment and safety devices to ensure compliance with building and safety code requirements. 4.1 S-Plan Type - Monovalent 4.2 Extended S-Plan Type - Monovalent Heat Pump ATC Heat Pump ATC Flow Flexible pipe Auto Byp

heruntergeladen wurde: 11   Dateigröße: 977 kb   Hersteller: Goodman Mfg  
Kategorie: Pumps

If the pointer starts to rise quickly, (enters the yellow or red zone within 30 seconds) switch off at the external isolator and remove all air from the system. 19. When satisfied that all air has been expelled, start this process again from step 12. 20. Remove demand for CH and DHW. 21. Compressor and fan will stop. 22. Circulating pump will continue to run for a period of time (default setting in BTC.). 23. Set the ATC and BTC - details in sections 11.2 and 11.3 respectively. IMPORTANT When pu

heruntergeladen wurde: 8   Dateigröße: 829 kb   Hersteller: Goodman Mfg  
Kategorie: Pumps
@name

High pressure is measured at the suction service valve ( the larger valve). AMPS = Outdoor unit amps (comp.+fan) Low pressure is measured at the gauge port connection. KW = Total system power HEATING SPECIFICATIONS Model: GHS140181A* / CA*F3131B6A*+TXV / MBR800**-1 Condition: 600 CFM Indoor Air @ 70°F DB Outdoor Ambient °F. Basic Unit without Auxiliary Heat Capacity of Unit With KW of Auxiliary heat capacity btuh c.o.p. 4.8 9.6 14.4 19.2 65 22.63 4.23 39.008 55.391 71.7732 88.156 60 21.42 4.09 3

heruntergeladen wurde: 9   Dateigröße: 829 kb   Hersteller: Goodman Mfg  
Kategorie: Pumps
@name

+fan) EXPANDED PERFORMANCE DATA COOLING OPERATION MODEL: GSH140361A* / CA*F4860C6A* +TXV / MBR1600**-1 Design Subcooling 9 ± 3° F @ the liquid service valve, ARI 95 test conditions Outdoor Ambient Temperature65 75 85 95 105 115 Entering Indoor Wet Bulb TemperatureIDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 1198 MBh 33.9 35.1 38.5 - 33.1 34.3 37.6 - 32.3 33.5 36.7 - 31.5 32.7 35.8 - 30.0 31.1 34.0 - 27.8 28.8 31.5 - S/ T 0.71 0.60 0.41 - 0.74 0.62 0.43

heruntergeladen wurde: 18   Dateigröße: 829 kb   Hersteller: Goodman Mfg  
Kategorie: Pumps
@name

• All safety information must be followed as provided in the Service Manual. Models listed on page 3. GSH 14 SEER Remote Heat Pump RT6213004 April 2006 This manual is to be used by qualified HVAC technicians only. Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures performed by an unqualified person. TECHNICAL INFORMATION MANUAL Copyright © 2006 Goodman Manufacturing Company, L.P. ® PRODUCT IDENTIFICATION The model number is used f

heruntergeladen wurde: 8   Dateigröße: 829 kb   Hersteller: Goodman Mfg  
Kategorie: Pumps
@name

+fan) EXPANDED PERFORMANCE DATA COOLING OPERATION MODEL: GSH140181A* / CA*F3131B6A*+ TXV / MBR800**-1 Design Subcooling, 9 ± 3 °F @ the liquid service valve, ARI 95 test conditions Outdoor Ambient Temperature65 75 85 95 105 115 Entering Indoor Wet Bulb TemperatureIDB* Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 675 MBh 18.3 18.7 19.9 21.3 17.8 18.2 19.5 20.8 17.4 17.8 19.0 20.3 17.0 17.4 18.5 19.8 16.1 16.5 17.6 18.8 14.9 15.3 16.3 17.4 S/ T 0.93 0.87 0.71