See limited warranty document for details. B Model 2HP14 Split System Heat Pump seer 14 2 HP 14 B 36 P - 1 A Model Number Guide Refrigerant – 2 = R22 AC = Condenser HP = Heat Pump 14 - 14 SEER Nominal Family / Coil Protection B = Non-Louvered L = Louvered A = Service Level Revision Code Voltage P - 208-230v/60hz Single Phase Nominal Capacity 36 - 36,000 Btuh Model Voltage/ Hz/ Phase Voltage Range Min. Circuit Amp. Maximum Over Current Device (amps) Compressor Fan Motor Refrig. Charge (oz.): Weig
100 13,200 7.70 16,700 3.44 10,400 2.30 650 3/4 3/8 3/4 3/8 3/4 3/8 0.051 H4TXV01 E(C,M,U)1P29NA MPGAV050,075 13.5 11.5 18,100 13,200 7.70 16,700 3.44 10,400 2.30 650 3/4 3/8 3/4 3/8 3/4 3/8 0.051 H4TXV01 E(C,M,U)1P36NA,NB CMPEV050, 075, 100 13.5 11.5 18,200 13,300 7.80 16,700 3.48 10,400 2.34 650 3/4 3/8 3/4 3/8 3/4 3/8 0.051 H4TXV01 E(C,M,U)1P36NA,NB,NC MPGAV050,075,100,125 13.5 11.5 18,200 13,300 7.80 16,700 3.48 10,400 2.34 650 3/4 3/8 3/4 3/8 3/4 3/8 0.051 H4TXV01 4HP13*24 RBCS2M24C*****P -
Circuit Amp. Max. Overcurrent Device (amps) Compressor Fan Motor Refrig. Charge (oz.) Weight (lbs.) Rated Load (amps) Locked Rotor (amps) Rated Load (amps) Rated HP Nom. RPM Wire Guard/ Louvered 4HP13*18P 208-230/60/1 197/253 11.90 20 9.0 48 0.7 1/10 1075 117 151/166 4HP13*24P 208-230/60/1 197/253 11.10 15 8.3 43 0.7 1/10 1075 130 169/185 4HP13*30P 208-230/60/1 197/253 14.4 20 10.6 54 1.1 1/5 1075 159 186/203 4HP13*36P 208-230/60/1 197/253 19.6 30 14.7 74 1.2 1/4 1075 151 197/208 4HP13*42P 208-2
Outdoor Model Indoor Model Outdoor Ambient Temperature 65 60 55 50 47 45 40 35 30 25 20 17 15 10 4HP13*18P1A RBCS2M18C *****P Btuh 21,500 20,200 18,700 17,500 16,800 16,300 15,400 14,300 13,100 12,300 10,900 10,500 9,800 8,700 Kw 1.58 1.55 1.53 1.50 1.49 1.480 1.47 1.46 1.44 1.43 1.42 1.41 1.40 1.39 COP 3.98 3.82 3.58 3.42 3.30 3.22 3.06 2.86 2.66 2.52 2.24 2.18 2.04 1.84 4HP13*24P1A RBCS2M24C *****P Btuh 24,100 23,500 22,800 22,000 21,400 20,800 19,200 17600 16200 14700 13000 11800 11200 9200 K
For assistance or additional information, consult a qualified installer or service agency. WARNING Installation and servicing of air conditioning equipment can be hazardous due to internal refrigerant pressure and live electrical components. Only trained and qualified service personnel should install or service this equipment. Installation and service performed by unqualified persons can result in property damage, personal injury, or death. WARNING If this unit is to be installed in a mobile or
2 Unit Location & Installation ................................ 2 Rooftop Installation & Recommendations .................... 3 Indoor Coil Piston Selection ............................... 3 Refrigeration Line Sets ................................... 3 Installation of Line Sets .................................. 4 Leak Check ........................................... 4 Evacuating & Charging ................................... 4 Opening Service Valve ................................... 5 Electri
! Indoor fan motor is on correct speed tap. 2. Set thermostat selector switch to OFF and fan control switch to "Auto" is so equipped. 3. Close electrical disconnects to energize system. 4. Set room thermostat at desired temperature. Be sure set point is below indoor ambient temperature. 5. Set the system switch of the thermostat on COOL (or HEAT if applicable) and fan switch for continuous operation (ON) or AUTO, as desired. There will be a 5 minute short cycle compressor delay on startup. Opera
Model Number Guide 2 SH 13 B 24 P - ---- 1 A 2 -R22 Minor Revision Code Package Heat Pump 13 -13 SEER Nominal Series Major Revision Code Voltage 208-230V/60Hz/1Ph Nominal Cooling 24 -24,000 Btuh Physical Model Outside Fan Indoor Blower Wheel dia. X width (in.) Refrigerant Charge (oz.) Weight (lbs.)Diameter (in.) Nominal RPM 2SH13B24P 22 1075 10 x 6 129 380 2SH13B30P 22 1075 10 x 6 121 380 2SH13B36P 22 1075 10 x 8 152 400 2SH13B42P 26 825 10 x 10 186 509 2SH13B48P 26 825 10 x 10 188 520 2SH13B60P