|
Anleitung Zusammenfassung
High pressure is measured at the suction service valve ( the larger valve). AMPS = Outdoor unit amps (comp.+fan) Low pressure is measured at the gauge port connection. KW = Total system power HEATING SPECIFICATIONS Model: GHS140181A* / CA*F3131B6A*+TXV / MBR800**-1 Condition: 600 CFM Indoor Air @ 70°F DB Outdoor Ambient °F. Basic Unit without Auxiliary Heat Capacity of Unit With KW of Auxiliary heat capacity btuh c.o.p. 4.8 9.6 14.4 19.2 65 22.63 4.23 39.008 55.391 71.7732 88.156 60 21.42 4.09 37.802 54.185 70.5672 86.950 55 20.16 3.93 36.542 52.925 69.3072 85.690 50 18.85 3.75 35.228 51.611 67.9932 84.376 45 17.44 3.54 33.824 50.207 66.5892 82.972 40 16.20 3.36 32.582 48.965 65.3472 81.730 35 14.94 3.16 31.322 47.705 64.0872 80.470 30 13.55 2.88 29.933 46.315 62.6975 79.080 25 12.51 2.72 28.889 45.271 61.6535 78.036 20 11.52 2.56 27.899 44.281 60.6638 77.046 15 10.47 2.39 26.855 43.237 59.6198 76.002 10 9.40 2.19 25.778 42.161 58.5432 74.926 5 8.33 1.99 24.713 41.095 57.4775 73.860 0 7.26 1.78 23.647 40.029 56.4117 72.794 -5 6.20 1.56 22.581 38.964 55.346 71.728 -10 5.08 1.31 21.461 37.843 54.2258 70.608 Model: GSH140241A* / CA*F3636B6A*+TXV / MBR800**1 Condition: 850 CFM Indoor Air @ 70°F DB Outdoor Ambient °F. Basic Unit without Auxiliary Heat Capacity of Unit With KW of Auxiliary heat capacity btuh c.o.p. 4.8 9.6 14.4 19.2 65 30.17 4.30 46.550 62.933 79.315 95.698 60 28.56 4.14 44.942 61.325 77.707 94.090 55 26.88 3.98 43.262 59.645 76.027 92.410 50 25.13 3.79 41.510 57.893 74.275 90.658 45 23.26 3.58 39.638 56.021 72.403 88.786 40 21.60 3.39 37.982 54.365 70.747 87.130 35 19.92 3.19 36.302 52.685 69.067 85.450 30 18.76 2.91 35.146 51.528 67.911 84.293 25 17.32 2.74 33.700 50.083 66.465 82.847 20 15.95 2.58 32.330 48.712 65.095 81.477 15 14.50 2.40 30.884 47.267 63.649 80.031 10 13.01 2.21 29.393 45.776 62.158 78.541 5 11.54 2.00 27.918 44.300 60.682 77.065 0 10.06 1.79 26.442 42.824 59.207 75.589 -5 8.58 1.57 24.966 41.348 57.731 74.113 -10 7.03 1.32 23.415 39.797 56.180 72.562 Model: GSH140301A* / CA*F3636B6A*+TXV / MBR1200**-1 Condition: 1,080 CFM Indoor Air @ 70°F DB Outdoor Ambient °F. Basic Unit without Auxiliary Heat Capacity of Unit With KW of Auxiliary heat capacity btuh c.o.p. 4.8 9.6 14.4 19.2 65 34.69 4.53 51.076 67.458 83.8404 100.223 60 32.84 4.37 49.226 65.609 81.9912 98.374 55 30.91 4.19 47.294 63.677 80.0592 96.442 50 28.90 4.00 45.280 61.662 78.0444 94.427 45 26.74 3.77 43.127 59.509 75.8916 92.274 40 24.84 3.57 41.222 57.605 73.987 90.370 35 22.91 3.36 39.290 55.673 72.0552 88.438 30 20.93 2.97 37.311 53.694 70.0763 86.459 25 19.32 2.80 35.699 52.081 68.4638 84.846 20 17.79 2.63 34.170 50.553 66.9352 83.318 15 16.18 2.45 32.558 48.940 65.3227 81.705 10 14.51 2.25 30.895 47.277 63.660 80.042 5 12.87 2.04 29.249 45.631 62.0137 78.396 0 11.22 1.82 27.603 43.985 60.3676 76.750 -5 9.57 1.59 25.957 42.339 58.7215 75.104 -10 7.84 1.34 24.227 40.609 56.9914 73.374 Model: GSH140361A* / CA*F4860C6A*+TXV / MBR1600**-1 Condition: 1,065 CFM Indoor Air @ 70°F DB Outdoor Ambient °F. Basic Unit without Auxiliary Heat Capacity of Unit With KW of Auxiliary heat capacity btuh c.o.p. 4.8 9.6 14.4 19.2 65 43.49 4.37 59.875 76.257 92.6394 109.022 60 41.17 4.22 57.556 73.939 90.3212 106.704 55 38.75 4.04 55.134 71.517 87.8992 104.282 50 36.23 3.86 52.609 68.991 85.3734 101.756 45 33.53 3.64 49.910 66.292 82.6746 99.057 40 31.14 3.45 47.522 63.905 80.2872 96.670 35 28.72 3.25 45.100 61.483 77.8652 94.248 30 26.94 2.98 43.325 59.707 76.0895 92.472 25 24.87 2.82 41.249 57.631 74.0137 90.396 20 22.90 2.65 39.281 55.664 72.046 88.428 15 20.82 2.46 37.205 53.588 69.9701 86.353 10 18.68 2.26 35.065 51.447 67.8295 84.212 5 16.56 2.06 32.946 49.328 65.7104 82.093 0 14.44 1.84 30.827 47.209 63.5914 79.974 -5 12.33 1.61 28.708 45.090 61.4723 77.855 -10 10.10 1.35 26.480 42.863 59.2451 75.628 Model: GSH140421A* / CA*F4860D6A*+TXV / MBR2000**-1 Condition: 1,400 CFM Indoor Air @ 70°F DB Outdoor Ambient °F. Basic Unit without Auxiliary Heat Capacity of Unit With KW of Auxiliary heat capacity btuh c.o.p. 4.8 9.6 14.4 19.2 65 49.78 4.56 66.160 82.542 98.9244 115.307 60 47.12 4.39 63.506 79.889 96.2712 112.654 55 44.35 4.21 60.734 77.117 93.4992 109.882 50 41.46 4.02 57.844 74.226 90.6084 106.991 45 38.37 3.79 54.755 71.137 87.5196 103.902 40 35.64 3.59 52.022 68.405 84.7872 101.170 35 32.87 3.38 49.250 65.633 82.0152 98.398 30 31.24 3.16 47.627 64.009 80.3919 96.774 25 28.84 2.98 45.220 61.602 77.9846 94.367 20 26.56 2.81 42.938 59.320 75.7027 92.085 15 24.15 2.61 40.531 56.913 73.2954 89.678 10 21.67 2.40 38.048 54.430 70.8129 87.195 5 19.21 2.17 35.591 51.973 68.3554 84.738 0 16.75 1.94 33.133 49.516 65.898 82.280 -5 14.29 1.70 30.676 47.058 63.4405 79.823 -10 11.71 1.43 28.093 44.475 60.8577 77.240 Model: GSH140481A* / CA*F4860D6A* +TXV / MBR2000**-1 Condition: 1,550 CFM Indoor Air @ 70°F DB Outdoor Ambient °F. Basic Unit without Auxiliary Heat Capacity of Unit With KW of Auxiliary heat capacity btuh c.o.p. 4.8 9.6 14.4 ...
Dieses Handbuch ist für folgende Modelle:Pumps - GSC140601A (829.43 kb)
Pumps - GSC140481A (829.43 kb)
Pumps - RT6213004 (829.43 kb)
Pumps - GSC140421A (829.43 kb)