Login:
heruntergeladen wurde: 4   Dateigröße: 89 kb   Hersteller: Giant  
Kategorie: Pumps
@name

Item Part # Description Qty. 39 05235 O-Ring for Seal Retainer 3 51A 05246 Valve Seat 1 42 05238 O-Ring 3 51B 07653 O-Ring for Valve Seat 1 44 05240 V-Sleeve 9 51C 05247 Inlet Valve Seat 1 47A 05242 O-Ring 6 51D 07732-0100 Valve Spring 1 51F 05248 Valve Spring Guide 1 Oil Seal Kit # 09612 52A 07658 O-Ring 2 Item Part # Description Qty. 32 07624 Radial Shaft Seal 3 33A 07627 O-Ring 3 5 GP7170-4000 REPAIR INSTRUCTIONS NOTE: Always take time to lubricate all metal and non-metal parts with a light f

heruntergeladen wurde: 9   Dateigröße: 93 kb   Hersteller: Giant  
Kategorie: Pumps
@name

Item Part # Description Qty. Item Part # Description Qty. 41A 07721 O-Ring 3 51A 12564 Valve Seat 6 32 06118 Radial Shaft Seal 3 41B 13223 Support ring 3 51B 12565 Valve Plate 6 32A 13215 Grooved Ring 3 41C 12055 O-Ring 6 51C 12566 Valve Spring 6 33A 07721 O-Ring 3 41D 07693 Support Ring 6 52 05166 O-Ring 6 44 06096 Sleeve 6 57 05167 O-Ring 3 45 13360 Leakage Seal 3 GP6132 TORQUE SPECIFICATIONS Position Item# Description Torque Amount 10 13133 Inner Hexagon Screw 30 ft.-lbs. 36 13219 Plunger Con

heruntergeladen wurde: 7   Dateigröße: 116 kb   Hersteller: Giant  
Kategorie: Pumps
@name

The following information is to be considered as a general outline for installation. If you have unique requirements, please contact Giant Industries, Inc. or your local distributor for assistance. 1. The pump should be installed flat on a base to a maximum of a 15 degree angle of inclination to ensure optimum lubrication. 2. The inlet to the pump should be sized for the flow rate of the pump with no unnecessary restrictions that can cause cavitation. Teflon tape should be used to seal all joi

heruntergeladen wurde: 14   Dateigröße: 116 kb   Hersteller: Giant  
Kategorie: Pumps
@name

To compute specific pump horsepower requirements, use the following formula: (GPH X PSI) / 1450 = HP GP7155A, GP7255A PU R LLEY SI EQUIRE ELECTION & HORSEPOWER MENTS PUMP PULLEY MOTOR PULLEY RPM GPM 800 PSI 1000 PSI 1300 PSI 1500 PSI 2000 PSI 12.75 9.00 479 45.0 25.7 32.1 41.8 48.2 64.3 12.75 9.75 531 49.9 28.5 35.6 46.3 53.5 71.3 12.75 10.75 585 55.0 31.4 39.3 51.1 58.9 78.6 12.75 11.70 638 60.0 34.3 42.9 55.7 64.3 85.7 12.75 12.75 700 65.8 37.6 47.0 61.1 70.5 94.0 3 Exploded Vi

heruntergeladen wurde: 11   Dateigröße: 116 kb   Hersteller: Giant  
Kategorie: Pumps
@name

Gas engine power outputs must be approximately twice the pump power requirements shown above. We recommend that a 1.1 service factor be specified when selecting an electric motor as the power source. To compute specific pump horsepower requirements, use the following formula: (GPH X PSI) / 1450 = HP GP7150A PULLEY SELECTION & HORSEPOWER REQUIREMENTS PUMP PULLEY MOTOR PULLEY RPM GPM 8QQ PSI 1QQQ PSI 13QQ PSI 15QQ PSI 19QQ PSI 12.75 5.75 3QQ 23.4 13.4 16.7 21.7 25.1 31.8 12.75 7.5Q 4

heruntergeladen wurde: 4   Dateigröße: 127 kb   Hersteller: Giant  
Kategorie: Pumps
@name

To release tension beforehand, strike the plugs 1 to 2 times with a steel hammer on the top (before removing them). When replacing them, make sure that the threads are coated with antiseize, e.g., ProPack550. To Check Suction and Discharge Valves Inlet Valves 1. Using a socket wrench, carefully remove valve plugs (41 and 43). Take out the suction valve adaptor (39) along with the suction valve assembly (34-38). 2. Using a soft tool, push the valve assembly (34-38) out of the suction valve adapto

heruntergeladen wurde: 4   Dateigröße: 127 kb   Hersteller: Giant  
Kategorie: Pumps
@name

2 Specifications Models P57 & P57-0011 U.S. ..................................... Metric Flow .............................................................. 1.3 GPM ............................. 5.1 Liters/min. Discharge Pressure (Continuous) ................. 5000 PSI ............................. 350 Bar Discharge Pressure (Intermittent) ................. 6525 PSI ............................. 450 Bar Max. Inlet Pressure ....................................... 145 PSI .........................

heruntergeladen wurde: 7   Dateigröße: 134 kb   Hersteller: Giant  
Kategorie: Pumps
@name

But, if it is used carelessly and without regard to its potential hazard, it can cause serious injury. IMPORTANT OPERATING CONDITIONS Failure to comply with any of these conditions invalidates the warranty. 1. Prior to initial operation, add oil to the crankcase so that oil level is between the two lines on the oil dipstick. DO NOT OVERFILL. Use Giant recommened Oil Crankcase oil should be changed after the first 50 hours of operation, then at regular intervals of 500 hours or less dependin

heruntergeladen wurde: 5   Dateigröße: 134 kb   Hersteller: Giant  
Kategorie: Pumps
@name

To compute specific pump horse power requirements, use the following formula: HP = (GPM X PSI) / 1450 9 10 P200A-3100/5100 SERIES PARTS LIST ITEM PART NO. DESCRIPTION QTY. ITEM PART NO. DESCRIPTION QT 1 08300 Crankcase 1 17 08442 Wrist Pin 3 2 08301 Dipstick 1 19 08356-0010 Oil Seal 3 3 08302 Crankcase Plug Cover 1 20 08444-0100 Seal Retainer, 316 S.S. 3 3A 07190-0100 Drain Plug & Gasket 1 21 12260-0001 O-Ring (“-3100” pumps) 3 4 08005 O-Ring 1 21 08443 O-Ring (“-5100” pumps) 3 5 08

heruntergeladen wurde: 3   Dateigröße: 163 kb   Hersteller: Giant  
Kategorie: Pumps
@name

0.94 Volumetric Efficiency @ 3450 RPM ...................................................... 0.87 Mechanical Efficiency @ 3450 RPM...................................................... 0.86 Consult the factory for special requirements that must be met if the pump is I to operate beyond one or more of the limits specified above. I NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 deg