Login:
heruntergeladen wurde: 8   Dateigröße: 32 kb   Hersteller: Carrier  
Kategorie: Pumps
@name

operation. Your heat pump is designed to automatically melt the ice. When in this defrost cycle, it is normal for steam or SAFETY CONSIDERATIONS fog to rise from the outdoor unit. Do not be alarmed! Note to Installer:This manual should be left with the equipment user. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of these or any other appliances. Failure to follow this warning could result in fire, serious injury, or death. Do not use this unit if any part ha

heruntergeladen wurde: 11   Dateigröße: 45 kb   Hersteller: Carrier  
Kategorie: Pumps
@name

The tube end must stay bottomed in the service valve during final assembly to ensure proper seating, sealing, and rigidity. MECHANICAL FITTING REPAIR To replace damaged ferrule or tubing, proceed as follows. 1. Attach gages to service valves. 2. Close liquid service valve and operate unit in cooling mode to pump refrigerant charge into condenser coil. 3. When suction pressure reaches 5 psig, shut unit off. Do not operate unit in a vacuum. VALVE FITTING FERRULE LOCK NUT A92120 Fig. 4—Suction Serv

heruntergeladen wurde: 13   Dateigröße: 45 kb   Hersteller: Carrier  
Kategorie: Pumps
@name

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 4 PC 101 Catalog No. 563-809 Printed in U.S.A. Form 38YCB-2SI Pg 1 6-96 Replaces: 38YCB-1SI Tab 5a 5a AIR DISCHARGE FIELD POWER SUPPLY CONN 7.8. DIA HOLE WITH 1 1.8. DIA KNOCKOUT AND 1 3.8. DIA KNOCKOUT FIELD CONTROL SUPPLY CONN 7.8. DIA HOLE SUCTION LINE CONN LIQUID LINE CONN A93578 UNIT SIZE LIQUID TUBE VAPOR TUBE Conn Dia Tube Dia Conn Dia Tub

heruntergeladen wurde: 12   Dateigröße: 45 kb   Hersteller: Carrier  
Kategorie: Pumps
@name

Refer to Split-System Heat Pump Common Installation and Start-Up Practices (included in this packet). SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury, or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory-authorized kits

heruntergeladen wurde: 11   Dateigröße: 69 kb   Hersteller: Carrier  
Kategorie: Pumps
@name

Replace any worn or damaged parts. Replace the “O” ring (Item 3) anytime the impeller magnet housing is removed. Note: Pumps with 12 and 24 volt motors are available. Contact the factory for more information. REPAIR PARTS LIST ITEM DESCRIPTION QTY. PART NO. 1 #8 x 1-1/4 Long Rd. Hd. Screw 4 0923-0003-1000 2a Pump Housing w/.” MPT 1 0809-0013-0000 2b Pump Housing w/Center Inlet Style* 1 0809-0142-0000 2c Pump Housing Plastic w/.” MPT* 1 0809-0079-1000 3a “O” Ring, Silicon Rubber, used in bronze h

heruntergeladen wurde: 12   Dateigröße: 86 kb   Hersteller: Carrier  
Kategorie: Pumps
@name

See unit rating plate for recommended circuit- protection device. NOTE: Operation of unit on improper line voltage constitutes abuse and could affect unit reliability. See unit rating plate. Do not install unit in system where voltage may fluctuate above or below permissible limits. NOTE: Use copper wire only between disconnect switch and unit. NOTE: Install branch circuit disconnect of adequate size per NEC to handle unit starting current. Locate disconnect within sight from and readily accessi

heruntergeladen wurde: 12   Dateigröße: 86 kb   Hersteller: Carrier  
Kategorie: Pumps
@name

Allow 30-in. clearance to service end of unit and 48 in. above unit. For proper airflow, a 6-in. clearance on 1 side of unit and 12 in. on all remaining sides must be maintained. Maintain a distance of 24 in. between units. Position so water, snow, or ice from roof or eaves cannot fall directly on unit. C B A 3.8.D. (9.53) TIEDOWN KNOCKOUTS (2) PLACES A94199 Dimensions (In.) UNIT MINIMUM MOUNTING-PAD TIEDOWN KNOCKOUT LOCATIONS SIZE DIMENSIONS A B C 018-024 22-1/2 X 22-1/2 3-11/16 18-1/8 14-3/8 0

heruntergeladen wurde: 9   Dateigröße: 93 kb   Hersteller: Carrier  
Kategorie: Pumps
@name

If phasing is correct, circuit R-Y energizes contactor, starting outdoor-fan motor and compressor circuit. R-G energizes indoor unit-blower relay, starting indoor-blower motor on high speed. NOTE: If the phasing is incorrect, the contactor will not be energized. To correct the phasing, interchange any 2 of the 3 power connections on the field side. When thermostat is satisfied, its contacts open, de-energizing the contactor and blower relay. Compressor and motors should stop. NOTE: If indoor uni

heruntergeladen wurde: 13   Dateigröße: 161 kb   Hersteller: Carrier  
Kategorie: Pumps
@name

INSTALLATION RECOMMENDATIONS 1. Locate unit away from windows. 2. Ensure that vapor and liquid tube diameters are appropriate to capacity of unit. (See Table 1.) 3. Run refrigerant tubes as directly as possible by avoiding NOTE: Avoid contact between tubing and structure. LIQUID TUBE VAPOR TUBE VAPOR TUBE LIQUID TUBE INSULATION OUTDOOR WALL INDOOR WALL INSULATION CAULK THROUGH THE WALL HANGER STRAP (AROUND VAPOR TUBE ONLY) JOIST 1. MIN (25 mm) SUSPENSION unnecessary turns and bends. 4. Leave som

heruntergeladen wurde: 11   Dateigröße: 173 kb   Hersteller: Carrier  
Kategorie: Pumps
@name

2. Ice or frost tends to form on the coil during winter heating operation. Your unit is designed to automatically melt the ice. When in this defrost cycle, it is normal for steam or fog to rise from the outdoor unit, and for water to drain from the outside of unit. Do not be alarmed! To start the unit: 1. Turn on the electrical power supply to unit. 2. Set MODE control to desired mode and select temperature. To shut off unit: Note: If the unit is being shut down because of a malfunction, call yo