|
Dieses Gerät hat auch andere Anweisungen:
Anleitung Zusammenfassung
HOMEHOME UTILITYUTILITYSCENESCENE LEVELLEVEL MUTEMUTE ENTERENTERCANCELCANCEL 1. Holding down the [SCENE] and [ENTER] buttons 2. Press the [POWER] button Plug the PA-300 AC adaptor while holding down the [SCENE] and [ENTER] buttons. 01. Initialize DME: Returns to the factory setting. (Deletes all user settings except component data.) 02. Delete All Data: Deletes all data. 03. ==> Exit Diag Mode: Leaves this screen and restarts. ¦ A THRU connection function has been added. Even in an environment with no computer, you can check the connections without using DME Designer by directly connecting the DME64N/24N input/output. The meter does not operate during a connection check. This is set on the CHECK page of the utility screen. MODE: OFF Makes connections in the configuration used in the current scene. This is set to OFF when the unit is started. MODE: Thru Directly connects the Input and Output of each slot one-to-one for each channel. When input-only or output-only cards like AD or DA cards are inserted in the slots, you cannot perform checks in this mode. In the DME24N, the internal AD and internal DA are directly connected on each channel. 2 Notes for DME64N/DME24N Version 1.2 MODE: Summing Sums all input signals coming from Inputs (-12dB), without regard to device or card type, and outputs it through all Outputs. ¦ The Event Scheduler function allows day/time settings for events The settings are accessible via the Utility display “Misc” page. Refer to the “DME Designer Version 1.2 Owner’s Manual” for details. Event Scheduler Determines whether an event schedule setup in the DME Designer will be executed or not, and displays the current status. ON: The event will be executed. OFF: The event schedule will not be executed. ¦ A DAW control function has been added. With this function you can control the DME64N/24N from a DAW controller. 1. Parameter Control Function Lets you control DME64N/24N parameters using a DAW Controller. For example, if the PAN parameter is assigned to CH1 of the DAW controller, you can control the PAN parameter by operating a knob. There are two modes in the parameter control function, as follows: (1) General Parameter Operation Mode [KNOB] and [CH FADER] controls are used to operate internal parameters assigning them in DME Designer. For detailed settings, see the “DME Designer Version 1.2 Owner’s Manual.” (2) Final Output Stage Parameter Operation Mode Final output stage parameters are operated using [MUTE] and [CH FADER] controls. Unlike the General Parameter Control Mode, controls and the parameters that are compatible with them, are fixed in this mode. [Method of Operation] [^]: Switches to General Internal Parameter Control Mode. [Ў]: Switches to Final Output Stage Parameter Control Mode. [BANK <][BANK >]: The channels targeted for operation are shifted by the number of channels built into the DAW controller. [CH <][CH >]: The channels targeted for operation are...
Dieses Handbuch ist für folgende Modelle:Musikinstrumente - DME64N (542.33 kb)