• The individual manual shut-off must be a T-handle type valve. NEW YORK CITY APPROVAL New York City, NY (MEA) These fireplaces are approved for installation in New York City in the US state of New York if the following additional requirement is met: • An Outside Combustion Air Kit (FOAK-4, FOAK-4LD, or DK-4) must be installed. See Step 5 on Page 14. NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. SUPERIORSUPERIORB-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS COLd CLIMATE INSULATION For cold climate installations, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests, if floor is above ground level. Gas line holes and other openings should be caulked or stuffed with unfaced fiberglass insulation. Check local codes for additional requirements. If the fireplace is being installed on a cement slab in cold climates, a sheet of plywood or other raised, insulated platform can be placed underneath to prevent cold transfer to the fireplace and into the room. It also may help to sheetrock the inside surfaces and/or tape for maximum air tightness. LOCATION In selecting the location, the aesthetic and functional use of the appliance are primary concerns. However, vent system routing to the exterior and access to the fuel supply are also important. Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies (Figure 3). En raison des temperatures elevees, l’appareil devrait etre installe dans un endroit ou il y a peu de circulation et loin du mobilier et des tentures (Figure 3). The location should also be free of electrical, plumbing or other heating/air conditioning ducting. These appliances are equipped with an integral combustion air door and actuator arm. Combustion air kits are optional and must be installed before removing the securing screw allowing the movement of the combustion air actuator arm (see Step 5 on Page 14). Be aware that this is a heat-producing appliance. Objects placed above the unit are exposed to elevated temperatures. The appliance should be mounted on a fully supported base extending the full width and depth of the unit. The appliance may be located on or near conventional construction materials. However, if installed on combustible materials, such as carpeting, vinyl tile, etc., a metal or woodbarriercoveringtheentirebottomsurface must be used. These appliances may be used for bedroom installationsintheUnitedStatesandarelisted accordingly. These units may not be installed in bedrooms in Canada. Note: When the unit is installed with one side flush with a wall, see Figure 5 on Page 7. Figure 3: Typical Locations NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. - - . SUPERIORSUPERIORB-VENT GAS FIREPLACES • MODELS SLBV-35, SLBV-40 • INSTALLATION INSTRUCTIONS MINIMUM CLEARANCES TO COMBUS...

Dieses Handbuch ist für folgende Modelle:
Kamine - SLBV-35NE (2.89 mb)
Kamine - SLBV-35NE (2.89 mb)
Kamine - SLBV-35NE (2.89 mb)
Kamine - SLBV-35NE (2.89 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien