Login:
Stimmen - 2, Durchschnittliche Bewertung: 3.5 ( )

Anleitung Lennox Hearth, modell SLBV-35PM

Hersteller: Lennox Hearth
Dateigröße: 2.89 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Propane tanks are at pressures that will cause damage to valve components. Verify that the tanks have step-down regulators to reduce the pressure to safe levels. These appliances must be isolated from the gas supply piping system (by closing their individual manual shut-off valve) during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). These appliances and their individual shut-off valves must be disconnected from the gas supply piping system during any pressure testing of that system at pressures greater than 1/2 psig (3.5 kPa). ORIfICE SIzES Sea Level to High Altitude (All Models) These appliances are tested and approved for installation at elevations of 0–4500 feet (0–1372 meters) above sea level using the standard burner orifice sizes (marked with an asterisk (*) in Table 4, below). For elevations above 4500 feet, contact your gas supplier or a qualified service technician. deration At higher elevations, the amount of BTU fuel value delivered must be reduced by either: • using gas that has been derated by the gas company, • changing the burner orifice to a smaller size as regulated by the local authorities having jurisdictionandbythe(USA)NationalFuelGas Code NFPA 54/ANSI Z223.1 -latest edition or, inCanada,theCAN/CSA-B149.1codes -latest edition. Installtheapplianceaccordingtotheregulations of the local authorities having jurisdiction and, in the USA, the National Fuel Gas Code NFPA 54 / ANSI Z223.1 - latest edition or, in Canada, the CAN/CSA-B149.1 - latest edition. NOTE: Flame appearance will diminish 4% per thousand feet of altitude. Burner Orifice Sizes Elevation 0-4500 feet ( 0-1372 meters) Model Series Nat.Gas drill size (inches) Propane drill size (inches) SLBV-35 #48 (0.076")* H1236• #56 (0.046")* 62L37• SLBV-40 #43 (0.089")* 99K75• #55 (0.052")* 19L52• Table 4 *Standard size installed at factory. • Part /Catalog Number. GAS VALVE dIAGRAMS See Figure 1 for millivolt models and Figure 2 for electronic models. Main Gas Control Knob Pilot Adjustment Off/PILOT/ON Screw HILOWHTPTHTPTPILOTPILOTONitOFFINOUTHI/LO Variable flame Height Adjustment Manifold Pressure Tap Inlet Pressure Tap Figure 1 - SIT Millivolt Gas Valve Supply Pressure-TapRegulatorBurner Stage Gas (Manifold) Mounting Screw Terminal Inlet PILOT OUT VENT LO THTP TH TPHI IN IN Pilot Gas Pressure-Tap Ground Pilot Stage Outlet (Inlet) (TP) Terminal Figure 2 - Dexen Electronic Gas Valve REqUIREMENTS fOR THE COMMONWEALTH Of MASSACHUSETTS These fireplaces are approved for installation in the US state of Massachusetts if the following additional requirements are met: • Install this appliance in accordance with Massachusetts Rules and Regulations 248 C.M.R. • Installation and repair must be done by a plumber or gas fitter licensed in the Commonwealth of Massachusetts. • The flexible gas line connector used shall not exceed 36 inches (92 centimeters) in length. • The individual manual shut-off must be a T-handle type valve. ...

Dieses Handbuch ist für folgende Modelle:
Kamine - SLBV-35NE (2.89 mb)
Kamine - SLBV-35NE (2.89 mb)
Kamine - SLBV-35NE (2.89 mb)
Kamine - SLBV-35NE (2.89 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien