|
Anleitung Zusammenfassung
Step 4. Install field Wiring CAUTION Ground supply lead must be con nected to the wire attached to the green ground screw located on the outlet box. See Figure 13. failure to doso willresultin a potential safety hazard. The appliance must be electricallygroundedinaccordance withlocalcodesor,intheabsenceof local codes, the National Electrical Code, ANSI/NfPA 70 latest edition. (In Canada, the current CSA C22-1 Canadian Electrical Code). CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors cancauseimproperanddangerousoperation. ATTENTION : Au moment de l'entretien des commandes, etiquetez tous les fils avant de les debrancher. Des erreurs de cablage peuvent entrainer un fonctionnement inadequat et dangereux. Verify proper operation after installing. A. All Models • An optional unit-mounted ON/OFF switch may be installed in the lower control compartment. • An optional wall-mounted ON/OFF switch or optional ON/OFF remote control kit also may be used. • If a wall-mounted ON/OFF control switch is used, mount it in a convenient location on a wall near the fireplace. • If an optional Style View Door is used in conjunction with an optional unit-mounted ON/OFF switch, the switch may be mounted onto the Style View Door per instructions provided in kit. • The gas valve is set in place and pre-wired at the factory on all models. Refer to Section B (below) for millivolt appliances and Section C (below) for electronic appliances. B. Millivolt Wiring (see Figure 12) 1. Read Section A, “All Models,” at left. 2. Wire the control switch within the millivolt controlcircuitusingthe15feetof2conductor wire supplied with the unit. Note: The supplied 15 feet of 2 conductor wire has one end of each conductor connected to the gas valve circuit and the other end of each conductor placed loose inside the bottom compartment. CAUTION: do Not connect the optional wall switch to a 120V power supply. C. Electronic Wiring (see Figure 13) Note: The electronic appliance must be connected to the main power supply. 1. Read Section A, “All Models,” at left. 2. Route a 3-wire 120Vac 60Hz 1ph power supply to the appliance junction box. 3. Remove the electrical inlet cover plate from the side of the unit by removing the plate's securing screws (see Figures 8-1 and 8-2 on Pages 9 and 10). 4. Removethecoverplate'sknockout;then feed the power supply wire through the knockout opening and into the unit junction box. 5. Connect the black power supply wire to the lower outlet's red pigtail lead and the white power supply wire to the common terminal of the outlet as shown in Figures 13 and 14. 6. Connect ground supply wire to pigtail lead attached to outlet's green ground screw. Note: Remote receiver should be located in the wall, or if installed in the control compartment, pulled all the way forward and completely to the left or right against the corner posts. The glass enclosure panel must be removed first to place the receiver in the lower control compartment....
Dieses Handbuch ist für folgende Modelle:Kamine - SLBV-35NE (2.89 mb)
Kamine - SLBV-35NE (2.89 mb)
Kamine - SLBV-35NE (2.89 mb)
Kamine - SLBV-35NE (2.89 mb)