Login:
Stimmen - 4, Durchschnittliche Bewertung: 4 ( )

Anleitung Superior, modell SLBV-40NM

Hersteller: Superior
Dateigröße: 2.89 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


All appliances are factory-equipped with a flex ible gas line connector and 1/2-inch shutoff valve. (See Step 6 on Page 15.) NOTE: Gas line can be routed to either side. Reverse this illustration if routing to right side. Also see Figures 8-1 and 8-2. Figure 9: Route Gas Line 3" (76 mm) Left Side Front Corner of Fireplace Framing 6-1/2" (152 mm) Pipe Coupling(Recommended) Proper Sizing of Gas Line Properly size and route the gas supply line from the supply regulator to the area where the appliance is to be installed per requirements outlined in the National Fuel Gas Code, NFPA 54 - latest edition (USA) or CAN/CSA-B149.1 - latest edition (Canada). Never use galvanized or plastic pipe. Gas lines must be routed, constructed and made of materials that are in strict accordance with local codes and regulations. IMPORTANT: It is critical that a licensed installer perform this step strictly per NFPA. We recommend that a qualified, licensed plumber or gas fitter be hired to correctly size and route the gas supply line to the appliance. Installingagassupplylinefromthefuelsupplyto theapplianceinvolvesnumerousconsiderations of materials, protection, sizing, locations, controls, pressure,sediment,andmore.Certainlyno one unfamiliar and unqualified should attempt sizing or installing gas piping. • All appliances are factory-equipped with a flexible gas line connector and 1/2 inch shutoff valve (see Figure 17 on Page 15). • See Massachusetts Requirements on Page 4 for additional requirements for installations in the state of Massachusetts in the USA. • The gas supply line should NOT be connected to the appliance until Step 6 on Page 15). • A pipe joint compound rated for gas should be used on the threaded joints. Ensure that propane-resistant compounds are used in propane applications. Be very careful that the pipe compound does not get inside the pipe. • It is recommended to install a sediment trap in the supply line as close as possible to the appliance. Appliances using propane should have a sediment trap at the base of the tank. • Check with local building official for local code requirements (e.g., whether below- grade penetrations of the gas line are al lowed, etc.). IMPORTANT: If propane is used, be aware that if the tank size is too small (i.e., under 100 lbs if this is the only gas appliance in the dwelling; ref. NPFA 58), there may be pressure loss resulting in insufficient fuel delivery, which can result in sooting, severe delayed ignition, or other malfunctions. Any damage resulting from an improper installation, such as this, is not covered under the limited warranty. Step 3. Install Venting System and Exterior Termination These instructions should be used as a guideline and do not supercede local codes in any way. Installventingaccordingtolocalcodes,these instructions, the current National fuel Gas Code in the USA (ANSI-z223.1) or the current standards in Canada (CAN/CSA-B149.1). SLBV-35 and SLBV-40 series fireplaces must be vertically vented using...

Dieses Handbuch ist für folgende Modelle:
Kamine - SLBV-35NE (2.89 mb)
Kamine - SLBV-35NE (2.89 mb)
Kamine - SLBV-35NE (2.89 mb)
Kamine - SLBV-35NE (2.89 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien