DO NOT ATTEMPT TO LIFT IT BY YOURSELF. DO NOT DROP AND BREAK THE TANK. . Stand the tank upright and replace the bottom distributor assembly. Temporarily, plug the top end of the distributor (use rag, etc.) to prevent accidental mineral spills into it. 1 Using a large neck funnel (FIG. 6), first add 17 Ibs. of gravel, followed by 10 Ibs. of filter sand. Next, add the 1 cu. ft. of activated carbon. Use water sparingly to assist carbon flowthrough the funnel. NOTE: Be sure the bottom distributor is centered in the tank while adding mineral. 10. Use water to flush the tank top opening. Then, replace the top distributor and 3 o-rings. Be sure to locate o-ring seals correctly... FIG. 7, page 14. 11. Carefully, install the valve assembly and retaining clamps. DOUBLE-CHECK TO BE SURE CLAMPS AND RETAINERS ARE SECURELY FASTENED IN PLACE. 12. Referring to your installation manual, reconnect the filter to the plumbing. BE SURE THE PLUMBING IS HELD FIRMLY IN PLACE, IN THE VALVE INLET AND OUTLET. 13. Place the valve drain hose at the drain point and secure in place. 14. Return the plumbing bypass valve(s) to SERVICE position. 15. Plug the transformer into the wall outlet. The filter will complete the backwash cycle, started in step 1, and will automatically return to service. NOTE: All new carbon mineral contains some smaller than normal particles called "fines." Backwashing the filter removes the fines. If, after the backwash in step 15 is over, fines are still in the filtered water, repeat step 1 for added backwashing. 16 SECTION 3 CARE OF YOUR FILTER II 3D. BEFORE YOU CALL FOR SERVICE . . . HELPFUL HINTS CHECKLIST PROBLEM FILTER WILL NOT BACKWASH LOW WATER PRESSURE AT HOUSE FAUCETS FILTERED WATER CONTAINS SEDIMENTS, IRON, DIRT, SAND, ETC. NEUTRALIZER FILTER ONLY: FILTER WATER IS ACID OR PARTLY ACID NOTE: Trace plumbing to be sure faucet(s) is on filtered water service. TASTE & ODOR FILTER ONLY: FILTERED WATER HAS BAD TASTE AND/OR ODOR NOTE: Trace plumbing to be sure faucet(s) is on filtered water service. CAUSE Manual bypass valve(s) in bypass position Transfomer unplugged at wall outlet, power cable disconnected, fuse blown/cimuit breaker popped, or circuit switched off Timer in the vacation (VAC) positFon Timer not programmed for backwash An error code shows in the face plate display Backwash flow washer plugged Drain hose plugged, kinked or bent Well pump pressure switch set too low Backwash needed more often to keep tilter mineral clean See all conditions under Filter Will Not Backwash,above. Manual bypass valve(s) in bypass position Filter low on neutralite mineral Manual bypass valve(s) in bypass position Activated carbon mineral bed is exhausted CORRECTION See FIG. 8, page 18. Move stem in a single bypass valve to SERVICE. In a 3-valve bypass, open the inlet and outlet valves, close the bypass valve. Check for loss of power and correct. Reset the times and use the BACKWASH NOW feature.., see page 9. Also see "Electric Power Outlet For Your Filter, page 17 in the installation manual. Press the VACATION button [] once to return the filter to service.., see page 9. See page 8 to program a weekly sched ule. See page 9. See key No. 38, page 26, and remove drain hose adaptor to clean. Straighten hose, or remove and clean. Adjust to a minimum of 20 psi. See page 8 to program more backwashes. See above. Add new mineral.., see page 14. See above. Replace mineral.., see page 16. 17 SECTION 4 THI.GS OTHERTOK.OW II 4A. DIMENSIONS/SPECIFICATIONS BYPASS VALVES SINGLE-PLASTIC --2711"-... DIA. PULL STEM .9 cm OUTWARD FOR SERVICE Inlet-Outlet Push Inward For Bypass 3-VALVE II IIjBypass 55" 139.6 cm 49" 124.5...
Dieses Handbuch ist für folgende Modelle:Wasserfilter - Kenmore 625.348241 (1.17 mb)
Wasserfilter - Kenmore 625.348234 (1.17 mb)
Wasserfilter - Kenmore 625.348251 (1.17 mb)
Wasserfilter - Kenmore 625.348241 (1.17 mb)