Contact Gazco for further information. IMPORTANT The front casing of this appliance will become hot whilst in operation, it is therefore recommended that a suitable guard shouldbe used for the protection of young children, the elderly or infirm. Please read these Instructions carefully before installation or use. Keep them in a safe place for future reference and when servicing the cooker. The commissioning sheet found at the end of the Users Sections of these instructions should be completed by
Once the Safe Start Check operation passes, the control turns on the spark circuit and at the same time, the S8701/S8702 opens the gas control’s main valves, which allows gas to flow to the main burner. Power is supplied to the generator until: • The main burner(s) lights and the flame sensor current reaches 1.0 m A, or • The ignition activation period ends If the main burner lights, a flame sensing circuit is completed through the flame to the burner head to ground. This current flow sets the T
S8701/S8702 controls are valve. The S8702 is compatible with dual rod systems used to ignite the main burner(s), sense the flame and only. control the gas valve in these applications, see Table 1. Table 1. S8701/S8702 Models. Model Flame Sense Trials for Ignition Spark/Sense Prepurge S8701D remote 1 1 No S8702D remote 1 2 No S8702F remote 3a 2 No S8702K remote 1 2 Yes S8702M remote 3a 2 Yes aS8702 F and M models include an auto-reset from lockout after 1 hour. Planning the Installation WARNING F