Manual No. 203519GS Revision - (07/25/2007) Thank you for purchasing this quality-built Briggs & Stratton trash pump. We are pleased that you’ve placed your confidence in the Briggs & Stratton brand. When operated and maintained according to the instructions in this manual, your Briggs & Stratton trash pump will provide many years of dependable service. This manual contains safety information to make you aware of the hazards and risks associated with trash pumps and how to avoid them. This trash
• Anchor pump to avoid “walking” or equipment movement, especially if located near a ditch or edge of open ravine. The equipment could fall in. • Keep equipment away from edge of river or lake where it could cause the bank to collapse. • DO NOT insert any objects through cooling slots. 4 KNOW YOUR WATER PUMP 5 KNOW YOUR WATER PUMP Read this Operator’s Manual and safety rules before operating your water pump. Compare the illustrations with your water pump, to familiarize yourself with the locatio
Starter Handle — Used to start the engine. Strainer Basket (not shown) — Used to limit passage of abrasive materials into the pump. Suction Inlet — Connect reinforced suction hose here. Engine Speed Lever — Used to adjust engine speed to control pump output. Water Drain Plug — Remove to drain water from pump and flush internal components with clean water. Fuel Tank Air Cleaner On/Off Switch Water Drain Plug Choke Lever Starter Handle Priming Plug Oil Fill Cap Discharge Outlet Serial Number Label
Total Head is the sum of the suction head value plus the discharge head value. As water pumping height increases, pump output decreases. The length, type, and size of the suction and discharge hoses can also significantly affect pump output. It is important for the suction operation to be the shorter part of the total pumping action.This will decrease the priming time and improve pump performance by increasing the discharge head. Suction head is a maximum of 25 feet and discharge head should be
All service and adjustments should be made at least once each season. Follow the requirements in the “Maintenance Schedule” chart above. NOTE: Once a year you should clean or replace the spark plug and replace the air filter.A new spark plug and clean air filter assure proper fuel-air mixture and help your engine run better and last longer. Emissions Control Maintenance, replacement or repair of the emissions control devices and systems may be performed by any non-road engine repair establishmen
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Product Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Common Service Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Espanol Francais 3 Operator Safety Equipment Description Read this manual carefully and become familiar with your water pump. Know its appli
High Altitude At altitudes over 5,000 feet (1524 meters), a minimum 85 octane / 85 AKI (89 RON) gasoline is acceptable. To remain emissions compliant, high altitude adjustment is required. Operation without this adjustment will cause decreased performance, increased fuel consumption, and increased emissions. See an Authorized Briggs & Stratton dealer for high altitude adjustment information. Operation of the engine at altitudes below 2,500 feet (762 meters) with the high altitude kit is not reco
. . . . . . . . . . . . . . . . . . . . . . . . .1.5 in (38 mm) Total Head . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .225 ft (69 m) Maximum Head Suction Lift . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 ft (8 m) Discharge Lift . . . . . . . . . . . . . . . . . . . . . . . . 200 ft (61 m) Maximum Discharge Capacity . 132 US gal (500 l) per minute Shipping Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75 lbs. Engine Specifications Rated Horsepower
111th Street 420 Burbrook Place Indianapolis, IN 46280 London, ON N6A 4L6 This warranty is extensive in that it covers replacement of all defective parts and even finish, but these are the only two things that are covered. LABOR CHARGES AND/OR DAMAGE INCURRED IN INSTALLATION, REPAIR, OR REPLACEMENT AS WELL AS ANY OTHER KIND OF LOSS OR DAMAGES ARE EXCLUDED. Proof of purchase (original sales receipt) from the original consumer purchaser must be made available to Delta for all warranty claims. THIS
Escriba aqui el numero del modelo comprado. Inscrivez le numero de modele ici. SILICONETEFLONIcons You may need/Usted puede necesitar/ Articles dont vous pouvez avoir besoin: WARNING: THIS FAUCET IS NOT TO BE USED WITH PORTABLE DISHWASHERS! / ADVERTENCIA: .SESTA LLAVE NO SE DEBE UTILIZAR CON MAQUINAS LAVAPLATOS PORTATILES! / AVERTISSEMENT: ON NE DOIT PAS BRANCHER UN LAVE-VAISSELE PORTATIF SUR CE ROBINET! MEETS OR EXCEEDS — ASME A112.18.1 / CSA B125.1 ALCANZA O EXCEDE LAS SIGIENTES NORMAS — ASME