Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.3 ( )

Anleitung Briggs & Stratton, modell 073002

Hersteller: Briggs & Stratton
Dateigröße: 4.49 mb
Dateiname: 3d13ba8a-09af-41e4-fddf-52b5a656186b.pdf
Unterrichtssprache:enesfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


All service and adjustments should be made at least once each season. Follow the requirements in the “Maintenance Schedule” chart above. NOTE: Once a year you should clean or replace the spark plug and replace the air filter.A new spark plug and clean air filter assure proper fuel-air mixture and help your engine run better and last longer. Emissions Control Maintenance, replacement or repair of the emissions control devices and systems may be performed by any non-road engine repair establishment or individual. See emissions control system warranty, elsewhere in this manual. Maintenance Maintenance consists of keeping the water pump clean. Store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the water pumps engine must not become clogged with dirt, leaves or any other foreign material. NOTE: DO NOT use a garden hose to clean water pumps engine.Water can enter engine fuel system and cause problems. Cleaning Daily or before use, look around and underneath water pump for signs of oil or fuel leaks. Clean accumulated debris from inside and outside water pump. Keep linkage, spring and other engine controls clean. Keep area around and behind muffler free from any combustible debris. Engine parts should be kept clean to reduce the risk of overheating and ignition of accumulated debris. • Use a damp cloth to wipe exterior surfaces clean. • Use a soft bristle brush to loosen caked on dirt or oil. • Use a vacuum cleaner to pick up loose dirt and debris. 17 MAINTENANCE • Use low pressure air (not to exceed 25 psi) to blow away dirt. Inspect cooling air slots and opening on water pump. These openings must be kept clean and unobstructed. Remove silt and sludge buildup in pump body: • Open priming plug and remove drain plug. • Flush internal components of pump with clean water. Oil Oil Recommendations NOTE: When adding oil to the engine crankcase, use only high quality detergent oil rated with API service classification SF, SG, SH, SJ or higher. DO NOT use special additives. 1. Choose a viscosity according to the table below: Syn5W-30, 10W-30 thetic 5W-30, 1030 W-30 °F -20 0 20 32 40 60 80 100 °C -30 -20 -10 0 10 20 30 40 STARTING TEMPERATURE RANGE ANTICIPATED BEFORE NEXT OIL CHANGE * The use of multi-viscosity oils (5W-30, 10W-30, etc.) in temperatures above 40°F (4°C) will result in higher than normal oil consumption.When using a multi-viscosity oil, check oil more frequently. ** The use of SAE 30 oil in temperatures below 40°F (4°C) will result in hard starting and possible engine bore damage due to inadequate lubrication. NOTE: Synthetic oil meeting ILSAC GF-2,API certification mark and API service symbol with “SJ/CF ENERGY CONSERVING” or higher, is an acceptable oil at all temperatures. Use of synthetic oil does not alter required oil change intervals. Checking Oil Level Oil level should be checked prior to each use or at least every 8 hours of operation. Keep oil level maintained. 1. Make sure unit is on a level surface. 2. Remove oil fill cap and wipe clean with cloth. 3. Verify oil is at the point of overflowing at oil fill opening. Adding Engine Oil 1. Make sure unit is on a level surface. 2. Check oil level as described in “Checking Oil Level”. 3. If needed, slowly pour oil into oil fill opening to the point of overflowing at oil fill cap. Changing Engine Oil Change the oil after the first 5 hours of operation. Change oil every 50 hours thereafter. If you are using your water pump under extremely dirty or dusty conditions, or in extremely hot weather, change the oil more often. CAUTION Avoid prolonged or repeated skin contact with used motor oil. • • Used motor oil has been shown to cause skin cancer in certain laboratory animals. Thoroughly wash exposed areas with soap and water. KEEP OUT OF REACH OF CHILDREN. DON'T POLLUTE. CONSERVE RESOURCES. RETURN USED OIL TO COLLECTION CENTERS. Change the oil while the engine is still warm from running, as follows: 1. Make sure unit is on a level surface. 2. Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug. WARNING Unintentional sparking can result in fire or electric shock. WHEN ADJUSTING OR MAKING REPAIRS TOYOUR WATER PUMP • Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug. WHEN TESTING FOR ENGINE SPARK • Use approved spark plug tester. • DO NOT check for spark with spark plug removed. 18 MAINTENANCE 3. Clean area around oil drain plug.The oil drain plug is located at base of engine, opposite carburetor (Figure 17). Figure 17 — Oil Drain Plug and Oil Fill Cap Oil Drain Plug Oil Fill Opening 4. Remove oil drain plug and drain oil completely into a suitable container. 5. Reinstall oil drain plug and tighten securely. Remove oil fill cap. 6. Slowly pour oil (about 20 oz.) into oil fill opening to the point of overflowing at oil fill cap (Figure 17). DO NOT overfill. ...

Dieses Handbuch ist für folgende Modelle:
Plumbing - 073001 (4.49 mb)
Plumbing - 073003 (4.49 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien