Login:
Stimmen - 1, Durchschnittliche Bewertung: 3 ( )

Anleitung Briggs & Stratton, modell Water Transfer Pump

Hersteller: Briggs & Stratton
Dateigröße: 3.91 mb
Dateiname: 84a139ed-c44a-0c84-f15e-936abdc3f79c.pdf
Unterrichtssprache:enesfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


High Altitude At altitudes over 5,000 feet (1524 meters), a minimum 85 octane / 85 AKI (89 RON) gasoline is acceptable. To remain emissions compliant, high altitude adjustment is required. Operation without this adjustment will cause decreased performance, increased fuel consumption, and increased emissions. See an Authorized Briggs & Stratton dealer for high altitude adjustment information. Operation of the engine at altitudes below 2,500 feet (762 meters) with the high altitude kit is not recommended. Attach Suction Hose You will need the following tool to install the hoses to the water pump: • 1/4" or 6mm standard screwdriver Connect Suction Hose to Pump Use a commercially available hose. The suction hose must be reinforced with a non-collapsible wall or braided material. DO NOT use a hose with an inside diameter smaller than the pumps suction port size. 1. Slide barb cuff (B) over hose barb (C). Insert rubber seal (D) into end of barb cuff. D B C 2. Screw hose barb assembly onto pump in clockwise rotation until hose barb assembly is tightened securely. 8 BRIGGSandSTRATTON.COM 9 3. Slide hose clamp (A) over end of hose (B). Slide suction hose onto hose barb (C). Tighten hose clamp securely using a standard 1/4” (6mm) screwdriver. Attach Suction Hose to Strainer Basket Slide hose clamp over hose. Attach open end of suction hose to strainer hose barb. Tighten hose clamp securely using a standard 1/4” (6mm) screwdriver. Connect Discharge Hose (Optional) If desired, use a commercially available hose. DO NOT use a hose with an inside diameter smaller than the pump’s discharge port size. 1. Slide barb cuff over hose barb. Insert rubber seal into end of barb cuff as shown earler. 2. Screw hose barb assembly onto pump in clockwise rotation until hose barb assembly is tightened securely. 3. Slide hose clamp over end of discharge hose. Slide discharge hose onto hose barb. Tighten hose clamp securely using a standard 1/4” (6mm) screwdriver. A C B Features and Controls Read this Operator’s Manual and safety rules before operating your water transfer pump. Compare the illustrations with your water transfer pump, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference. G E J F K D Unit may vary slightly from that shown H L M N P S CBA R A - Fuel Tank — Fill tank with regular unleaded fuel. Always leave room for fuel expansion. B - Priming Plug — Fill pump with water here to prime pump before starting. C -Discharge Outlet — Connect discharge hose here. D -Choke Lever — Prepares a cold engine for starting. E -Air Cleaner — Protects engine by filtering dust and debris out of intake air. F -Recoil Starter — Used for starting the engine manually. G -Engine Speed Lever — Used to adjust engine speed to control pump output. H -On/Off Switch — Set this switch to “On” before using recoil starter. Set switch to “Off” to stop a running engine. J - Oil Drain — Drain engine oil here. K -Oil Fill — Check and add engine oil here. L -Data Tag — Provides model and serial number of water transfer pump. Please have these readily available if calling for assistance. M -Suction Inlet — Connect reinforced suction hose here. N -Water Drain Plug — Remove to drain water from pump and flush internal components with clean water. P - Pump Chamber — Be sure to fill with water before starting. R -Engine Information — Stamped on valve cover. Provides model, type and code number of engine. Please have these readily available when calling for assistance. S - Fuel Shutoff Valve — Used to turn fuel supply on and off to engine. Item Not Shown: Strainer Basket — Used to limit passage of abrasive materials into the pump. 10 1010 BRIGGSandSTRATTON.COM BRIGGSandSTRATTON.COMBRIGGSandSTRATTON.COM Operation If you have any problems operating your water transfer pump, please call the water transfer pump helpline at (800) 743-4115. Safe Operating Considerations WARNING Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire. • Keep at least 5 ft. (1.5 m) clearance on all sides of water transfer pump including overhead. Clearances and Air Movement Place water transfer pump outdoors in an area that will not accumulate deadly exhaust gas. DO NOT place water transfer pump where exhaust gas (A) could accumulate and enter inside or be drawn into a potentially occupied building. Ensure exhaust gas is kept away from any windows, doors, ventilation intakes, or other openings that can allow exhaust gas to collect in a confined area. Prevailing winds and air currents should be taken into consideration when positioning water transfer pump. WARNING Running engine gives off carbon monoxide, an odorless, colorless, poison gas. Breathing carbon monoxide can cause headache, fatigue, dizziness, vomiting, confusion, seizures, nausea, fainting or death. • Operate water transfer pump ONLY outdoors. • Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien