Install the anchors. Seal the wall around the anchors with waterproof sealant. Hold the panel against the wall. Install the gray plastic insert. Insert the top screw through the front of the panel, the washer and the insert. Screw it into the anchor. Install the center and bottom screws and washers. Connect the supply hoses to the hot and cold supply elbows. Connect the supply hoses to the hot and cold inlet ports on the valve. Turn the water on at the main. Push the diverter stem up to turn the

heruntergeladen wurde: 2   Dateigröße: 5 mb   Hersteller: Axor  
Kategorie: Plumbing

Installation in 90° corner Installation .. flat wall Wrap the threads on the nipples with Teflon tape. Install the elbows so that the outlets face upwards. Measure up the wall 78 .", making sure that the line is plumb. Mark the position for the top screw hole. From the position of the top screw hole, measure down 35 3/8”. Mark the position for the center screw hole. From the center screw hole, measure down 19 1/8". Mark the position for the bottom screw hole. Use a 6 mm bit to drill the three sc

heruntergeladen wurde: 1   Dateigröße: 5 mb   Hersteller: Axor  
Kategorie: Plumbing
@name@name

Install the elbows so that the outlets face upwards. Measure up the wall 78 .", making sure that the line is plumb. Mark the position for the top screw hole. From the position of the top screw hole, measure down 35 3/8”. Mark the position for the center screw hole. From the center screw hole, measure down 19 1/8". Mark the position for the bottom screw hole. Use a 6 mm bit to drill the three screw holes. Install the set screws in the top and bottom holes. Use a 10 mm nut driver to attach a nut t

heruntergeladen wurde: 0   Dateigröße: 5 mb   Hersteller: Axor  
Kategorie: Plumbing
@name

This diagram shows both possible positions for the installation. Installation in 90. corner Only one set of supplies is required – do not install two sets of supplies. Installation in 90. Corner Seal the wall around the supplies with waterproof sealant. Failure to seal the wall can lead to possible water damage. 1 2 3 4 5 6 7 8 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 9 10 Seal the wall around the anchors with waterproo

heruntergeladen wurde: 1   Dateigröße: 5 mb   Hersteller: Axor  
Kategorie: Plumbing

.........................La bague de retenue maintiendra l’anneau de montage a la bonne hauteur. Deposez la valve sur la surface de montage... Tournez les valves de facon a ce que les conduites de sortie soient face au centre. Serrez l’ecrou de montage et les vis de serrage. Installation du bec Ecartement Swing C et Limbo.. C: ............Placez l’anneau decoratif du bec sur la surface de montage... Inserez le bec dans l’anneau decoratif. Ecartement E et Tango C: .................Placez le bec e

heruntergeladen wurde: 0   Dateigröße: 5 mb   Hersteller: Axor  
Kategorie: Plumbing
@name@name

Push the end of the hose into the valve outlet. Tighten the compression nut wrench tight. Do not allow the connecting hose to twist, or it will become loosened from the spout. Repeat with the second connection hose. Install the handles Swing C, Tango C, Limbo C only: Install the deco-rings on the handles All models: Hold the lever in the desired “off” position with one hand. With the other hand, turn the bell clockwise, so that it threads down over the valve stem. Install the pull rod Solaris E,

heruntergeladen wurde: 3   Dateigröße: 4 mb   Hersteller: Axor  
Kategorie: Plumbing
@name

These blocks need to increase the depth of the bracket to between 56 mm and 67 mm from the finished surface (fig.44). Decide on the shower position and whether the hot and cold water supplies will enter the shower from the top (falling), the bottom (rising) or the rear. Mark the wall for an opening of about 93 mm diameter. Cut the opening and offer the mounting bracket up to the back of the panel (fig.45). Mark the inner fixing holes and drill the panel and wooden support blocks. If installi

heruntergeladen wurde: 6   Dateigröße: 3 mb   Hersteller: Axor  
Kategorie: Plumbing
@name

Protection against back siphonage provided by check valves. The check valves should be removed and inspected yearly (see page 8). This panel may be used with an instantaneous water heater if the heater is at least 24 kW and the output is at least 3 gpm @ 30 psi pressure. However, only one panel function may be used at a time. *Please know and follow all applicable local plumbing codes when setting the temperature on the water heater. In Massachusetts, the water heater may be set no higher than 1

heruntergeladen wurde: 2   Dateigröße: 3 mb   Hersteller: Axor  
Kategorie: Plumbing
@name

Screw the hose to the handshower. If the flow of water becomes noticeably less, remove and clean the screen washer. Scale Removal The Raindance Air 3-jet handshower incorporates the Quick Clean™ cleaning system. If scale deposits are noticed in the spray channels, turn the water on lightly and rub the spray channels with a finger or a sponge. If scale deposits are noticed on the spray face, pour about 3/4” of a commercial scale remover, such as Lime-Away™ or CLR™ ,into a shallow dish. Dilute the

heruntergeladen wurde: 2   Dateigröße: 3 mb   Hersteller: Axor  
Kategorie: Plumbing

Screw the hose to the handshower. If the flow of water becomes noticeably less, remove and clean the screen washer. Scale Removal The Raindance Air 3-jet handshower incorporates the Quick Clean™ cleaning system. If scale deposits are noticed in the spray channels, turn the water on lightly and rub the spray channels with a finger or a sponge. If scale deposits are noticed on the spray face, pour about 3/4” of a commercial scale remover, such as Lime-Away™ or CLR™ ,into a shallow dish. Dilute the