These blocks need to increase the depth of the bracket to between 56 mm and 67 mm from the finished surface (fig.44). Decide on the shower position and whether the hot and cold water supplies will enter the shower from the top (falling), the bottom (rising) or the rear. Mark the wall for an opening of about 93 mm diameter. Cut the opening and offer the mounting bracket up to the back of the panel (fig.45). Mark the inner fixing holes and drill the panel and wooden support blocks. If installing a fixed head, fit the outlet adaptor into the top outlet hole in the valve housing (fig.16). The adaptor is sealed with an 'O' ring. Make sure the adaptor is fitted with the hose end in the valve housing (fig.17). Fit the blanking plug into the bottom outlet hole using an 'O' ring to seal it. If installing a bulkhead outlet, fit the outlet adaptor into the bottom outlet hole in the valve housing. The adaptor is sealed with an 'O' ring. Make sure the adaptor is fitted with the hose end in the valve housing (fig.17). Fit the blanking plug into the top outlet hole using an 'O' ring to seal it (fig.18). Make sure that the inlet elbows are facing the 18 Combi HP thermostatic mixer shower correct way. Offer the valve up to the mounting bracket and secure using the screws provided. Secure the mounting bracket together with the valve to the panel using two bolts in the innermost fixing holes (fig.46). Complete the pipework to the shower marking off the length to enter the elbows. Remove the valve and mounting bracket and cut the pipes to length. If fitting a fixed head, make a hole in the panel for the fixed head position. Note: Make sure the hole in the panel for the outlet pipe is no larger than required (either /" BSP or 15 mm). Should the shroud protrude beyond the wall surface, trim flush with a sharp knife (fig.34). Place a ring of silicon sealant round the flush mount plate up to the finished surface. Make sure the valve and plate are aligned, and secure in the outer fixing holes using the two bolts supplied (fig.47). Break off the alignment tabs on the flush mount plate (fig.36) and fit the flush mount cover (fig.48). Locate the lugs on the trim ring in the holes on the cover and twist clockwise (fig.49). Complete the fitting of your shower accessories. 19 Combi HP thermostatic mixer shower FLUSHING PROCEDURE Removal and/or fitting of check valves for maintenance IMpoRTANT: It is preferable to flush the pipework before installing the valve. Where this is not possible, the procedure using a flushing cartridge should be followed. a. Isolate the supplies. b. Remove the trim ring by twisting anticlockwise. c. Remove the valve cover. d. Remove the four screws holding the valve cartridge, and carefully remove the cartridge assembly from housing (fig.50). e. Insert the plastic tool provided into the inner sleeve located inside the elbow and twist anti-clockwise (fig.51). Take care not to damage the check valve. Note: The sleeve may stick, in which case it must be carefully hooked out using a suitable tool such as an allen key. f. Push the flushing cartridge into the housing (fig.52). Attach a hose to the flushing cartridge outlet and make sure it is directed to waste. Flush the pipes clean. g. wash out the sleeve and check valve. Take care not to damage them. h. Replace the check valve into the sleeve, making sure it is in the correct way (fig.53). i. Refit sleeve into the elbow. Carefully replace the valve cartridge and refit the cover. j. Reinstate supplies and test the valve operation. Note: It may be necessary to service the check valves at regular intervals to prevent cross flow of water. Note: Flushing cartridges and replacement check valve tools are available from Triton Customer Service. Flush the pipework to clear system of debris and check for leaks. 20 Combi HP thermostatic mixer shower FITTING THE TAMPERPROOF FIX-D HEAD (Exposed option only) Complete the outlet pipework from the valve and cut the pipe to required length. Place the fixed head unit on top of the pipe work and mark the position of the three fixing holes (fig.54). Drill and plug the holes using the plugs supplied. Secure the pipe to the fixed head unit using the compression nut and olive supplied (fig.55). Secure the fixed head to the wall with the three screws supplied (fig.56). Screw on the adjustable showerhead. Make sure the supplied flat sealing washer is in place (fig.57). Note: The showerhead must be screwed on tight to make sure of a watertight connection. Use a suitable tool if necessary. Using the allen key supplied, lock the showerhead in position by tightening the grub screw (fig.58). 21 Combi HP thermostatic mixer shower FITTING THE TAMPERPROOF FIX-D HEAD (Built in option only) complete outlet pipework from the valve ending in a /" BSP female threaded fitting (not supplied) (fig.59). Note: The depth of thread on the fixed head unit from wall surface is 18 mm (fig.60). It is advisable th...

Dieses Handbuch ist für folgende Modelle:
Plumbing - COMBI 2180206H (4.02 mb)
Plumbing - COMBI 2180206H (4.02 mb)
Plumbing - COMBI 2180206H (4.02 mb)
Plumbing - COMBI 2180206H (4.02 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien