Login:
heruntergeladen wurde: 0   Dateigröße: 121 kb   Hersteller: Wayne  
Kategorie: Plumbing
@name

Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Submersible Utility Pump Description This portable, submersible utility pump is designed for non-automatic use in water. The units are equipped with an 8 ft. 3-prong grounding type power cord. The motor is oil filled and sealed for cooler operation. The discharge fitting is designed for convenient at

heruntergeladen wurde: 1   Dateigröße: 121 kb   Hersteller: Wayne  
Kategorie: Plumbing
@name

If the power source is out of sight, lock and TAG IN OPEN (OFF) POSITION to prevent unexpected power application. Failure to do so could result in fatal electrical shock! This unit is not designed for use in septic tanks or underground vaults to pump raw sewage or effluents. Never use in hazardous or explosive locations. 1. This pump has been designed to attach to a standard garden hose. Thread the female end of the garden hose to the male discharge on the pump. 2. To reduce leakage between the

heruntergeladen wurde: 2   Dateigröße: 256 kb   Hersteller: Wayne  
Kategorie: Plumbing
@name@name@name

The pump motor is equipped with automatic resetting thermal protector and may restart unexpectedly. Protector tripping is an indication of motor overloading as a result of operating the pump at low heads (low discharge restriction), excessively high or low voltage, inadequate wiring, incorrect motor conditions, or a defective motor or pump. 14. This pump is designed to transfer water in cycles. Using this pump in a continuous duty application by manipulating the switch to stay on, will effect th

heruntergeladen wurde: 0   Dateigröße: 256 kb   Hersteller: Wayne  
Kategorie: Plumbing
@name@name@name

Low line voltage 2. Debris caught in impeller or discharge 3. Worn or defective pump parts or plugged impeller 4. Pump running backwards 5. Pump not properly sized for application 6. Check valve stuck closed or installed backwards 7. Shut off valve closed 1. If voltage is under recommended minimum, check wiring size from the main switch on property. If OK, contact power company 2. Remove, clean and check for tightness 3. Replace entire pump. Clean parts if required 4. Check rotation. (CCW from b

heruntergeladen wurde: 10   Dateigröße: 275 kb   Hersteller: Wayne  
Kategorie: Plumbing
@name@name@name

4. Place the pump in a suitable area where it can be cleaned thoroughly. Remove all scale and deposits on pump. 5. Submerge the complete pump in a disinfectant solution (10% chlorine bleach solution) for at least one hour before handling the pump. 6. Clean all dirt and deposits from the pump float. Make sure float moves freely after cleaning. 7. Clean all dirt and deposits away from pump inlet and volute. This pump contains dielectric motor oil for lubrication and motor heat transfer. This oil c

heruntergeladen wurde: 12   Dateigröße: 275 kb   Hersteller: Wayne  
Kategorie: Plumbing
@name@name@name

Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Operating Instructions and Parts Manual Models DSP60 and DSP75 Description A sewage pump is intended for use in domestic sewage lift stations. It is suitable for pumping sewage, effluent, wastewater, gro

heruntergeladen wurde: 6   Dateigröße: 275 kb   Hersteller: Wayne  
Kategorie: Plumbing
@name@name@name

Faulty float switch 1. Install check valve 2. Replace float switch 3. Check valve not installed or leaking 3. Remove and examine check valve for proper installation and free 4. Discharge head is less than operation manufacturer's minimum 4. Recheck all sizing calculations to determine proper pump size Pump shuts off and turns 1. Excessive water temperature 1. Pump should not be used for water above 120° on independently of 2. Defective switch or entangled switch 2. Replace or reposition pump swi

heruntergeladen wurde: 6   Dateigröße: 655 kb   Hersteller: Wayne  
Kategorie: Plumbing
@name@name@name

angle with the valve pivot on top. In a vertical position, solids will tend to lodge on the valve flapper and can prevent it from opening. 3. Drill a 1/8 inch hole in the discharge pipe approximately 1 inch to 2 inch above the pump discharge when a check valve is used. The hole prevents air locking of the pump at the initial start-up and if it should lose prime. 4. A gate valve should be installed in the system after the check valve. This gate valve should be a full port valve which will pass 2

heruntergeladen wurde: 0   Dateigröße: 655 kb   Hersteller: Wayne  
Kategorie: Plumbing
@name@name@name

Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Sewage Pump Description A sewage system consists of a pump, control switch, and a basin for use in applications where less than six toilets (units) are discharged into the basin. The system is generally controlled by a float switch with a plug-in-plug which accepts the pump plug and in turn plugs int

heruntergeladen wurde: 6   Dateigröße: 655 kb   Hersteller: Wayne  
Kategorie: Plumbing
@name@name@name

13-1/2 inch x 11 inch Intake ................................................. 2 inch Performance Discharge............................................ 2 inch NPT female, 3 inch NPT male Cut-in level (factory set)....................18 inch Cut-out level (factory set) ................. 10 inch GALLONS PER hOuR At tOtAL hEAD IN fEEt Model 10 15 200 SEL40 3700 1350 Differential......................................... 8 inch SEL50 6420 4200 1500 Switch..............................................





Kategorien