Login:
Stimmen - 4, Durchschnittliche Bewertung: 3.8 ( )

Anleitung Delta, modell SELECTRONIC 6067.22X

Hersteller: Delta
Dateigröße: 869.21 kb
Dateiname:
Unterrichtssprache:
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


customer's e-mail us at: faucetsupport@americanstandard.com For Parts, Service, Warranty or other Assistance, please call 1-800-442-1902 (In Canada: 1-800-387-0369) (In Toronto Area only: 1-905-3061093) 6065.22X 6067.22X 6068.22X MODEL NUMBERS 6065.26X 6067.26X 6068.26X M968550 REV. 1.6 Fig. 1 GENERAL DESCRIPTION: RECOMMENDED TOOLS; Fig. 2 Roughing-in Dimensions Concealed Flushometer for 1-1/2" Spud Fixtures SELECTRONIC™ PROXIMITY TOILET FLUSH VALVE Exclusive, self cleaning piston-type flush valve with proximity operation and manual override. Operates on DC (b a tte r y)or AC power. Recommended operating pressure 25psi (flowing) to 80 psi (static). Can install left or right-handed. Detection Zone can also be adjusted manually, or with optional remote control. -C-L-51mm (2) + WALL THICKNESS 51mm (2) 152mm (6) MIN. 71mm (2-3/4) DIA. 483mm (19) MAX. 25mm (1) MAX. 160mm (6-1/4) OVERRIDE BUTTON 160mm (6-1/4) 406mm (16) 127X127mm (5X5 CUTOUT FOR BOX) 127mm (5) MAX. 432mm (17 MAX.) 19mm (3/4.) 289 TO 403mm (11-3/8 MIN. TO 15-7/8 MAX.) *FOR LOCATION OF INLET SUPPLY ON BACK INLET FIXTURES,REFER TO FIXTURE BEING INSTALLED FOR CORRECT HEIGHT FROM FINISHED FLOOR 73 TO 137mm (2-7/8)MIN. TO (5-3/8) MAX. 403 TO 441mm (15-7/8) MIN. TO (17-3/8) MAX. FINISHED WALL CONCEALED BACK SPUD TOILET EXPOSED BACK SPUD TOILET TOP SPUD TOILET TOP SPUD TOILET TOP OF FIXTURE SENSOR SUPPLY DN 25mm (1) I.P.S. 115mm-134mm (4-1/2 TO 5-1/4) *Note: The Critical Line (-C-L-) on Vacuum Breaker must typically be 6" (152mm) min. above fixture. Consult Codes for details. 73 TO 111mm (2-7/8 TO 4-3/8) 292mm (11-1/2) MAX. 51mm (2) 51mm (2) -C-L-* WALL THICKNESS MAXIMUM DETECTION ZONE 400mm-800mm (15-3/4 TO 31-1/2) 15° 19mm (3/4.) TOP OF FIXTURE 1. Teflon Tape 2. Flat Blade Screwdriver 3. Adjustable Wrench 4. Tape Measure 5. Hacksaw 6. Tubing Cutter 7. File 8. For Sweat Connection; Solder and Torch 9. 2.5mm Hex Wrench 10. 1.5mm Hex Wrench Fig. 2 1 2 3 4 5 6 7 9 10 8 10' PRIOR TO INSTALLATION • Flush all water lines prior to operation (See Step 4). Dirt Note: Prior to installing the Selectronic™Flush Valve and debris can cause flush valve to run continuously. the following items must be installed. • With the exception of Supply Stop Inlet, DO NOT use pipe 1. Water Closet sealant or plumbing grease on any valve component or coupling! 2. Drain line • Protect the chrome or special finish on chrome plated 3. Water supply line items. DO NOT USE toothed tools on finished surfaces to install or IMPORTANT: service these valves. Also see “Care and Cleaning” section of this manual. applicable codes and regulations. • All plumbing must be installed in accordance with • This product contains mechanical and/or electrical components that are subject to normal wear. These • Water supply lines must be sized to provide an components should be checked on a regular basis and adequate volume of water for each fixture. replaced as needed to maintain the valve’s performance. M968550 REV. 1...

Dieses Handbuch ist für folgende Modelle:
Plumbing - SELECTRONIC 6065.22X (869.21 kb)
Plumbing - SELECTRONIC 6065.26X (869.21 kb)
Plumbing - SELECTRONIC 6068.22X (869.21 kb)
Plumbing - SELECTRONIC 6068.26X (869.21 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien