Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung American Standard, modell SELECTRONIC 6067.22X

Hersteller: American Standard
Dateigröße: 869.21 kb
Dateiname:
Unterrichtssprache:
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Insert EXTENSION WIRE CONNECTOR (9) into LOWER CIRCUIT BOARD RECEPTOR (10) on Unit #3. 10. Repeat Steps 7 to 9 as necessary for additional Multi-AC Units. 11. Once all wire connections are made. Install the COVER (2) and COVER SCREWS (1) onto each ELECTRICAL BOX (3). Fig. 15 Fig. 15a Fig. 15b 12 9 TOP TOP TOP 2 7a 7 8 3 6 1 5 4 9 TOP 10 SENSOR WIRE CONNECTOR SENSOR WIRE FROM UNIT #2 Unit #2 7a 7 8 3 9a TOP 12 7 12 8 8 8 8 12 11 10 9 SENSOR WIRE CONNECTOR FROM UNIT #3 BACK OF BOX (3) FROM UNIT #1 REMOVE KNOCK-OUT (11), INSERT WIRE GROMMET (12) 1 2 SENSOR WIRE SENSOR WIRE 6 10 7 6 10 13 7 6 10 13 13 M968550 REV. 1.6 13 HOWTO INSTALL NEW BATTERY; Fig. 16 1. Remove FRONT PANEL. For removing front panel see Step 9 for instructions. 2. Remove the four COVER SCREWS (1) and COVER (2) from ELECTRICAL BOX (3). Fig. 16. 3. Disconnect GREY SENSOR WIRE (4) from CIRCUIT BOARD (5). 4. Remove CIRCUIT BOARD (5) from ELECTRICAL BOX (3). Fig. 16a. 5. With your thumbs, spread the two TABS (6) on battery holder apart and remove the BATTERY (7). 2. Install NEW BATTERY (7) into holder on DC circuit board. Press BATTERY (7) down (contacts facing downward) into position until TABS (6) lock BATTERY (7) into place. 6. Install CUIRCUIT BOARD (5) and connect GREY SENSOR WIRE (4). 7. Install COVER (2) and SCREWS (1). 8. Replace and FRONT PANEL. See Step 9 for instructions on installing front panel. 14 ADJUST SUPPLY STOP; Fig. 17 IMPORTANT: To avoid overflowing, the SUPPLY STOP (2) must never be opened to the point where the flow from the valve exceeds the flow capacity of the fixture. The fixture must be able to handle a continuous flow in case of a flush valve failure. Valve is designed to provide stated flush volume with a 25 GPM flow rate. 1. After installation is complete, peel off the PROTECTIVE FILM (1) from the sensor. Standing to one side, block the sensor with your hand for 10 seconds. Remove your hand and listen for audible “click” from within the valve. 2. Turn on SUPPLY STOP (2) 1/4 turn to 1/2 turn(CCW) and test for leaks. Note: Unit may flush for approximately 5 to 10 sec. when water is first turned on. If flow persists, turn water off and repeat step #1 above. 3. Actuate the FLUSH VALVE: A) Cover sensor with hand for 10 seconds. NOTE: Stand outside of sensor detection aera. B) Remove hand from in front of the sensor; unit will flush in approximately 3 seconds. 4. Adjust SUPPLY STOP (2) after each flush until the stated flush volume is achieved, no splashing occurs and the fixture is properly cleansed. 3 57 6 TOP 10Fig. 16 Fig. 16a Fig. 17 1 4 2 3 5 TO P CLOCKWISE CLOSES CONTROL STOP COUNTER-CLOCKWISE OPENS CONTROL STOP 1 2 M968550 REV. 1.6 6 TO P Note: The detection distance is preset and is ideal formost installations. Should an adjustment be required follow the steps below. 1. Remove FRONT PANEL (1). See Step 9 for removing front panel instructions. 2. Remove the four COVER SCREWS (2) and COVER (3) from ELECTRICAL BOX (4). Fig. 18....

Dieses Handbuch ist für folgende Modelle:
Plumbing - SELECTRONIC 6065.22X (869.21 kb)
Plumbing - SELECTRONIC 6065.26X (869.21 kb)
Plumbing - SELECTRONIC 6068.22X (869.21 kb)
Plumbing - SELECTRONIC 6068.26X (869.21 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien