Anleitung Zusammenfassung
The type of gas, gas pressure and gas category are entered on the specification plate. Prior to connection, check that the appliance is set up for the type of gas available on site. To do this, compare the details on the specification plate with the existing gas data. • If this is not the case, the appliance must be converted or adapted by the service personnel responsible to suit local conditions. The following points should be noted: - Has the appliance been tested for the new gas data? - Conversion in accordance with the Service Manual. - A new specification plate or a durable marking with the new gas data must be affixed to the appliance. 4.1 CONNECTION Gas-only appliances as well as combination electric and gas appliances require a gas connection. The gas connection is located under the appliance on the right hand side. For all types the gas connection is NPT 3/4“. The installation of a dirt trap in the gas supply line by the owner is recommended. After connection, all lines carrying gas must be tested for leaks at operating pressure by painting with non-corrosive foam-forming media, (e.g. soapy water or leak spray). 4.2 GAS PRESSURE The current gas pressure should be measured at the Mertik regulator with a liquid U-tube manometer (scale at least 0.1 mbar = 1 mm water column). O Remove the control panel. The measuring nipple is located in downwards direction at the gas supply pipe before the two gas valves. O Close off the mains gas leading to the appliance. O The measuring nipple is provided at the left side of the regulator. The incoming pressure is measured in front, the outgoing pressure behind. O Loosen the slotted screw (1 turn) in the measuring nipple. Then connect the pressure gauge by attaching a flexible tube to the nipple (out-side diameter 8 mm). O Open the main gas leading to the appliance. O Run all burners on the appliance at full output. O Check whether the connection pressure is in permitted tolerance. O Turn off the appliance again. O Close the main gas valve. O Retighten the slotted screw in the measuring nipple. Gas pressure deviation tolerances are laid down by EN 203. If the existing gas pressure is outside the given tolerances, correct combustion can no longer be ensured. Compulsory measures: pressure adjustment by the gas works or conversion of the range by the service personnel. Please refer to "Conversion to another gas type". Gas pressure tolerances Gas pressure variation tolerances are as follows: mbar Gas typ e Norm press inch water g. ial ure mbar Min press inch water g. . ure mbar Natural gas USA A 7 17.4 3.5 8.7 Liquid gas Propane USA E 11 27.4 8.0 20 Seite 8 62.9677.01 UL OPERATING INSTRUCTIONS El Electrolux III . OPERATING INSTRUCTIONS 1. GENERAL The appliance is used for frying various types of meat, sausages, fish and vegetables on a gas-heated steel plate. Optionally the appliance is equipped with a smooth griddle plate or a combined grill/griddle plate with 1/3 grooved and 2/3 smooth surface. Plate temperature control is stepless and separate for the left and right halves of the plate. A drawer (GN container 2/8) in the open storage space in the base serves as a drip pan for draining liquids. Additional equipment: - GN container 1/1, 2/1, - Scraper grill/griddle. 2. OPERATION O For liquid gas operation also o...
Dieses Handbuch ist für folgende Modelle:Andere Küchengeräte - WHGUSAOOOO 9CHG584123 (877.51 kb)
Andere Küchengeräte - Thermaline 9CHG584123 (877.51 kb)
Andere Küchengeräte - Thermaline 9CHG584122 (877.51 kb)
Andere Küchengeräte - Thermaline 9CHG584124 (877.51 kb)