Inspect the pilot flame (remove logs, if necessary, handling carefully). The flame should be steady, not lifting or floating. Flame should be blue in color with traces of orange at the outer edge. For natural gas units the last ..." (10 mm) of the pilot generator (thermopile) and the top ..." (3.2 mm) min (tip) of the quick drop out thermocouple should be engulfed in the pilot flame (Figure 19 ). b. a. b. a. c. d. c. d. Figure 20 ..." Min ..." Min Natural Shown Thermopile Thermocouple Pilot Flame Position the front log assembly (c) over the pin located at the front of the left log rack bar and the back pin of the short (second from the right) log rack bar. Install the remaining right front log (d) over he last two pins located at the front of the right log rack bar and the short log rack bar respectively. The installation of the logs should be complete and resemble Figure 18. Figure 19 On propane models the last ..." (10mm) of the pilot generator should be engulfed in the pilot flame. The propane thermocouple is attached to the side of the pilot burner tube. Replace logs if removed for pilot inspection. To light the pilot, manually depress and hold the door safety switch (Figure 21 ) and rotate the control knob counterclockwise to the “PILOT” position and press in and light by pressing the piezo button (refer to lighting instructions on page 17 and Figure 20 ). Note: The door safety switch must be held closed and the rocker switch must be "ON" for burner operation (Figure 21 ). Door Swtich Rocker Swtich (Optional) Figure 21 To obtain proper operation, it is imperative that the main burner characteristics are steady. The flame should produce a clear, bright orange/ yellow flame. No smoke or soot elements should be visible. If questionable, check with your service man or gas supplier. The flames should not impinge on the logs, reposition them if necessary. E A TPTH TP TH PILOT PILOT ON it O FF SIT Millivolt Valve Gas Control Knob Piezo Ignitor Flame Adjustment Knob Honeywell Millivolt Valve Gas Control Knob Spark Ignitor ON OFF PILOT LO HI The flame height and BTU input may be altered by rotating the flame control valve from low to high. The flame height and BTU input may be altered by rotating the flame control valve from low to high. The air shutter on the venturi tube has been set at the factory for both natural and propane gas models, refer to Figure 22for air shutter settings. Orifice Burner Manifold Air Shutter Opening Air Shutter Opening (Not Adjustable) CF-5500 CF-6500 Natural Gas -...." Open Natural Gas -...." Open Propane Gas -..." Open Propane Gas -...." Open Figure 22 Flame Appearance REFER TO THE OPERATING INSTRUCTIONS LOCATED AT THE BACK OF THIS MANUAL BEFORE LIGHTING THE HEATER TO OBSERVE THE FLAMES. Note:Instructions are also found on the pullout panel located in the l ower control compartment of the appliance. Note:The door switch must be held closed for burner operation when testing. Flames from the pilot and main burner should be visually checked when the appliance is installed. In addition a periodic visual check of the flames should be made throughout the life of the appliance. The pilot flame should always be present when the heater is in operation and should just envelope the tip of the thermocouple (Figure 23). The main burner flames must not impinge on the logs with the exception of the charred areas, flame appearance should be as shown in Figure 24. Natural Pilot Propane Pilot Thermopile Thermocouple Thermopile Thermocouple Pilot Flame Pilot Flame Figure 23 WARNING: NO ADJUSTMENTS ARE TO BE MADE TO THE ODS PILOT SYSTEM. TAMPERING WITH THIS SYSTEM WILL VOID THE WARRANTY ...

Dieses Handbuch ist für folgende Modelle:
Kamine - STANDARD SERIES CF5500-CMN (598.98 kb)
Kamine - STANDARD SERIES CF5500-CMN (598.98 kb)
Kamine - STANDARD SERIES CF5500-CMN (598.98 kb)
Kamine - STANDARD SERIES CF5500-CMN (598.98 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien