Follow the instructions provided with the blower kit. Finished Wall Details It is sometimes best to frame the appliance after it has been positioned in place. Frame with 2 x 4s or heavier lumber. Always frame in accordance with local building codes. In order to install the appliance facing flush with the finished wall, position the framework to accommodate the thickness of the finished wall (Refer to Figures 2 and 3). If you live in a cold climate, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests, if floor is above ground level. WARNING: DO NOT ADD EXTRA LOGS OR ORNAMENTS SUCH AS PINE CONES, VER- MICULITE OR ROCK WOOL. USING THESE ADDED ITEMS CAN CAUSE SOOTING. WARNING: DO NOT PLACE ANY LAVA ROCK ON LOGS OR BURNERS. THIS MAY CAUSE SOOTING. Step 9. Ember Coal, Rockwool and Log Installation – The logs are packaged in a carton packed inside the firebox. Remove the ceramic fiber coals from their packaging and spread evenly in the area in front of the burner. Place the rockwool over the front half of the burner ports, avoiding the two groups of five larger holes (refer to Figure 17 ). Place ember coals in the confined area in front of the burner and behind the appliance front lip. Reinstall the log grate removed in preparing the insert. Secure the grate with the two (2) screws previously removed. WARNING: FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS HEATER MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY. Carefully position and center the fiber logs onto the burner in the manner illustrated (Figure 18). Positioning pins indicate log location. The flames should not impinge on the logs. Install the logs beginning with the right rear log first (a). Engage it as shown over the pin located at the back of the right log rack bar (Figure 18). Next, install the main log assembly (b) over the pin located at the back of the left log rack bar. The charred right nose of the main log rests directly on the burner pan positioned against the extension protruding from the right log rack bar, and the end of the short (second from the right) log rack bar. NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 9 Figure 18 Step 10. Checking the System – After the gas line is installed, logs are in place and the system is leak checked, run initial system checkout before closing up the front of the unit. Follow the pilot lighting instructions on pages 16 and 17. Note: Instructions are also found on the pull out panel located on the bottom surface of the appliance. When first lighting the appliance, it will take a few minutes for the line to purge itself of air. Once purging is complete, the pilot and burner will light and operate as indicated in the instruction manual. Subsequent lightings of the appliance will not require such purging. Inspect the pilot flame (remove logs, if necessary, handling carefully). The flame should be steady, not lifting or floating. Flame should be blue in color with traces of orange at the outer edge. For natural gas units the last ..." (10 mm) of the pilot generator (thermopile) and the top ..." (3.2 mm) min (tip) of the quick drop out thermocouple should be engulfed in the pilot flame (Figure 19 ). b. a. b. a. c. d. c. d. Figure 20 ..." Min ..." Min Natural Shown Thermopile Thermocouple Pilot Flame Position the front log assembly (c) over the pin located at the front of the left log rack bar and the back pin of the short (second from the right) log r...

Dieses Handbuch ist für folgende Modelle:
Kamine - STANDARD SERIES CF5500-CMN (598.98 kb)
Kamine - STANDARD SERIES CF5500-CMN (598.98 kb)
Kamine - STANDARD SERIES CF5500-CMN (598.98 kb)
Kamine - STANDARD SERIES CF5500-CMN (598.98 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien