INSTALLATION STEPS WARNING: DO NOT ALLOW FANS TO BLOW DIRECTLY INTO THE FIREPLACE. AVOID ANY DRAFTS THAT ALTER BURNER FLAME PATTERNS. WARNING: DO NOT USE A BLOWER IN- SERT, HEAT EXCHANGER INSERT OR OTHER ACCESSORY NOT APPROVED FOR USE WITH THIS HEATER. This appliance must not be operated without a front glass panel installed. Do not burn solid fuels in this listed unvented gas room heater. Step 1. Frame CF5500 appliance enclosures as illustrated in Figures 4, 5 and 6. Frame CF6500 appliance enclousures as illustrated in Figures 7, 8 and 9. Note:The framed depth (15..." for a flat wall, 29 ..." for a corner CF5500 and 19..." and 33..." for a CF6500) must always be measured from a finished surface. If a wall covering such as drywall is to be attached to the rear wall, then the dimension must be measured from the drywall surface. Note:Framing dimensions in Figures 4 - 9 are calculated for a nailing flange depth of..." (13 mm). Note:Framing dimensions in Figures 4 - 9 are calculated for a nailing flange depth of..." (13 mm). Chase/EnclosureIncluding Finishing 37" (940mm) 15..." (394mm) Outside Wall CF5500 Materials If Any. Figure 4 Back Wall of 37" (940mm) 58 .." (1473mm) 13 .." (343mm) 29" (737mm) 41" (1041mm) CF5500 Chase/EnclosureIncluding FinishingMaterials If Any. Figure 5 37 ..." (946 mm) 37" (940 mm) 15 ..." (394 mm) CF5500 Figure 6 The header may be in direct contact with the top metal spacers, but must not rest on them or be notched to fit around them. Step 2. Route a ..." (13 mm) gas line along the left or right side framing (see Figure 10). Back Wall of Chase/EnclosureIncluding Finishing Materials If Any. 41" (1041mm) 19 ..." (495mm) Outside Wall CF6500 Figure 7 Back Wall of Chase/Enclosure 41" (1041mm) 67 .." (1721mm) 14 .." (362mm) 33 .." (860mm) 47 .." (1216mm) Including FinishingMaterials If Any. CF6500 Figure 8 42 ..." (1076 mm) 41" (1041 mm) 19 ..." (495 mm) CF6500 Figure 9 All appliances have a 3" long ..." NPT nipple installed at the valve. To quickly and easily complete the gas line routing, use the gas flex line kit, Model GFLV. NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. Nailing Flange 3" (76 mm) CF6500 - 8..." (216 mm) CF5500 - 7..." (191 mm) Figure 10 Step 3. Remove the nailing flanges from the lower control compartment and install in place with three (3) screws each. Align with the three holes on each side of the appliance (see Figure 11). Figure 11 All units come complete from the factory with an installed hood. Ensure that the hood is installed. If required, position the hood in the open area above the appliance door covering the diverter baffles. Insert the tabs, on each end of the hood, into the bracket at each end. Bend the two tabs over to secure. Step 4. Position appliance into prepared framing, secure with 6d nails at the nailing flange along each side. Step 5. Connecting Gas Line – Make gas line connections. All codes require a shut-off valve mounted in the supply line. Figure 12illustrates two methods for connecting the gas supply. Installation methods and materials must be in compliance with local codes. NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. The gas control valve is located in the lower control compartment. To access the valve open the lower control compartment door (Figure 13). The control valve has a ..." NPT thread inlet port and is fitted with a 3" (76 mm) long nipple, ..." NPT on both ends. Plan the connections accordingly. D. When the gas lines are tested and leak free, observe the individual tongues of flame on the burner. Make sure all ports are open and pro- ducing flame evenly across the burner. If any ports are blocked, or partially blocked, cle...

Dieses Handbuch ist für folgende Modelle:
Kamine - STANDARD SERIES CF5500-CMN (598.98 kb)
Kamine - STANDARD SERIES CF5500-CMN (598.98 kb)
Kamine - STANDARD SERIES CF5500-CMN (598.98 kb)
Kamine - STANDARD SERIES CF5500-CMN (598.98 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien